Practical constraints on estimation of source extent with MEG beamformers

被引:47
作者
Hillebrand, Arjan [1 ]
Barnes, Gareth R. [2 ]
机构
[1] Vrije Univ Amsterdam, Med Ctr, Dept Clin Neurophysiol, Amsterdam, Netherlands
[2] UCL, Wellcome Trust Ctr Neuroimaging, London WC1N 3BG, England
基金
英国工程与自然科学研究理事会;
关键词
Spatial extent; Beamforming; Magnetoencephalography; Source modelling; Current density; Neuronal activity; SURFACE-BASED ANALYSIS; CORTICAL SOURCES; SOURCE RECONSTRUCTION; INVERSE PROBLEM; EEG; MAGNETOENCEPHALOGRAPHY; BRAIN; MODEL; SIGNALS; STROKE;
D O I
10.1016/j.neuroimage.2010.10.036
中图分类号
Q189 [神经科学];
学科分类号
071006 ;
摘要
We aimed to determine practical constraints on the estimation of the spatial extent of neuronal activation using MEG beamformers. Correct estimation of spatial extent is a pre-requisite for accurate models of electrical activity, allows one to estimate current density, and enables non-invasive monitoring of functional recovery following stroke. The output of an MEG beamformer is maximum when the correct source model is used, so that the spatial extent of a source can in principal be determined through evaluation of different source models with the beamformer. Here, we simulated 275-channel MEG data using sources of varying spatial extents that followed the cortical geometry. These data were subsequently used to estimate the spatial extent of generic disc elements without knowledge of the underlying surface, and we compared these results to estimates based on cortical surface geometry (with and without error in surface location). We found that disc-shaped source models are too simplistic, particularly for areas with high curvature. For areas with low curvature spatial extent was underestimated, although on average there was a linear relationship between the true and estimated extent. In contrast, cortical surface models gave accurate predictions of spatial extent. However, adding small errors (>2 mm) to the estimated location of the cortical surface abolished this relationship between true and estimated extent, implying that accurate co-registration is needed with such models. Our results show that models exploiting surface information are necessary in order to model spatial extent and in turn current density, but in order to render such models applicable in practical situations, the accuracy of the cortical surface model itself needs to improve. (C) 2010 Elsevier Inc. All rights reserved.
引用
收藏
页码:2732 / 2740
页数:9
相关论文
共 55 条
[1]   Co-registration of magnetoencephalography with magnetic resonance imaging using bite-bar-based fiducials and surface-matching [J].
Adjamian, P ;
Barnes, GR ;
Hillebrand, A ;
Holliday, IE ;
Singh, KD ;
Furlong, PL ;
Harrington, E ;
Barclay, CW ;
Route, PJG .
CLINICAL NEUROPHYSIOLOGY, 2004, 115 (03) :691-698
[2]   Cancellation of EEG and MEG Signals Generated by Extended and Distributed Sources [J].
Ahlfors, Seppo P. ;
Han, Jooman ;
Lin, Fa-Hsuan ;
Witzel, Thomas ;
Belliveau, John W. ;
Haemaelaeinen, Matti S. ;
Halgren, Eric .
HUMAN BRAIN MAPPING, 2010, 31 (01) :140-149
[3]   Modeling and detecting deep brain activity with MEG & EEG [J].
Attal, Yohan ;
Bhattacharjee, Manik ;
Yelnik, Jerome ;
Cottereau, Benoit ;
Lefevre, Julien ;
Okada, Yoshio ;
Bardinet, Eric ;
Chupin, Marie ;
Baillet, Sylvain .
2007 ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY, VOLS 1-16, 2007, :4937-+
[4]  
BAILLET S, 2000, P 12 INT C BIOM, P667
[5]  
BARNES GR, 2005, HUM BRAIN MAPP C TOR
[6]   Beamformer reconstruction of correlated sources using a modified source model [J].
Brookes, Matthew J. ;
Stevenson, Claire M. ;
Barnes, Gareth R. ;
Hillebrand, Arjan ;
Simpson, Michael. I. G. ;
Francis, Susan T. ;
Morris, Peter G. .
NEUROIMAGE, 2007, 34 (04) :1454-1465
[7]   Estimating parametric line-source models with electroencephalography [J].
Cao, Nannan ;
Yetik, Imam Samil ;
Nehorai, Arye ;
Muravchik, Carlos H. ;
Haueisen, Jens .
IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 2006, 53 (11) :2156-2165
[8]   A physiologically plausible spatio-temporal model for EEG signals recorded with intracerebral electrodes in human partial epilepsy [J].
Cosandier-Rimele, Delphine ;
Badier, Jean-Michel ;
Chauvel, Patrick ;
Wendling, Fabrice .
IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 2007, 54 (03) :380-388
[9]   Multiresolution imaging of MEG cortical sources using an explicit piecewise model [J].
Cottereau, Benoit ;
Jerbi, Karim ;
Baillet, Sylvain .
NEUROIMAGE, 2007, 38 (03) :439-451
[10]   Cortical surface-based analysis - I. Segmentation and surface reconstruction [J].
Dale, AM ;
Fischl, B ;
Sereno, MI .
NEUROIMAGE, 1999, 9 (02) :179-194