Monte Carlo modelling of external radiotherapy photon beams

被引:309
作者
Verhaegen, F [1 ]
Seuntjens, J [1 ]
机构
[1] McGill Univ, Med Phys Unit, Montreal, PQ H3G 1A4, Canada
关键词
D O I
10.1088/0031-9155/48/21/R01
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
An essential requirement for successful radiation therapy is that the discrepancies between dose distributions calculated at the treatment planning stage and those delivered to the patient are minimized. An important component in the treatment planning process is the accurate calculation of dose distributions. The most accurate way to do this is by Monte Carlo calculation of particle transport, first in the geometry of the external or internal source followed by tracking the transport and energy deposition in the tissues of interest. Additionally, Monte Carlo simulations allow one to investigate the influence of source components on beams of a particular type and their contaminant particles. Since the mid 1990s, there has been an enormous increase in Monte Carlo studies dealing specifically with the subject of the present review, i.e., external photon beam Monte Carlo calculations, aided by the advent of new codes and fast computers. The foundations for this work were laid from the late 1970s until the early 1990s. In this paper we will review the progress made in this field over the last 25 years. The review will be focused mainly on Monte Carlo modelling of linear accelerator treatment heads but sections will also be devoted to kilovoltage x-ray units and Co-60 teletherapy sources.
引用
收藏
页码:R107 / R164
页数:58
相关论文
共 256 条
[1]   A Monte Carlo based phase space model for quality assurance of intensity modulated radiotherapy incorporating leaf specific characteristics [J].
Aaronson, RF ;
DeMarco, JJ ;
Chetty, IJ ;
Solberg, TD .
MEDICAL PHYSICS, 2002, 29 (12) :2952-2958
[2]   PHOTONEUTRON DOSE IN SOFT-TISSUE PHANTOMS IRRADIATED BY 25 MV X-RAYS [J].
AGOSTEO, S ;
PARA, AF ;
GERARDI, F ;
SILARI, M ;
TORRESIN, A ;
TOSI, G .
PHYSICS IN MEDICINE AND BIOLOGY, 1993, 38 (10) :1509-1528
[3]   A PENCIL BEAM MODEL FOR PHOTON DOSE CALCULATION [J].
AHNESJO, A ;
SAXNER, M ;
TREPP, A .
MEDICAL PHYSICS, 1992, 19 (02) :263-273
[4]   COLLIMATOR SCATTER IN PHOTON THERAPY BEAMS [J].
AHNESJO, A .
MEDICAL PHYSICS, 1995, 22 (03) :267-278
[5]   ANALYTIC MODELING OF PHOTON SCATTER FROM FLATTENING FILTERS IN PHOTON THERAPY BEAMS [J].
AHNESJO, A .
MEDICAL PHYSICS, 1994, 21 (08) :1227-1235
[6]   APPLICATION OF THE CONVOLUTION METHOD FOR CALCULATION OF OUTPUT FACTORS FOR THERAPY PHOTON BEAMS [J].
AHNESJO, A ;
KNOOS, T ;
MONTELIUS, A .
MEDICAL PHYSICS, 1992, 19 (02) :295-301
[7]   SPECTRA OF INTERNALLY SCATTERED RADIATION FROM LARGE CO60 SOURCES USED IN TELETHERAPY [J].
AITKEN, JH ;
HENRY, WH .
INTERNATIONAL JOURNAL OF APPLIED RADIATION AND ISOTOPES, 1964, 15 (12) :713-&
[8]  
*AM ASS PHYS MED, 1986, 19 AAPM
[9]   CHAMBER-DEPENDENT WALL CORRECTION FACTORS IN DOSIMETRY [J].
ANDREO, P ;
NAHUM, A ;
BRAHME, A .
PHYSICS IN MEDICINE AND BIOLOGY, 1986, 31 (11) :1189-1199
[10]   STOPPING-POWER RATIO FOR A PHOTON SPECTRUM AS A WEIGHTED SUM OF THE VALUES FOR MONOENERGETIC PHOTON BEAMS [J].
ANDREO, P ;
NAHUM, AE .
PHYSICS IN MEDICINE AND BIOLOGY, 1985, 30 (10) :1055-1065