摘要
Dose calculations for intensity modulated radiation therapy (IMRT) require an accurate description of the radiation field defined by the multileaf collimator. A previously developed Monte Carlo phase space model has been modified to provide accurate dose verification for IMRT treatments on a Novalis linear accelerator. We have incorporated into the model the effects of the multileaf collimator geometry, including leaf transmission, interleaf leakage, the rounded leaf tips and the effects of leaf sequencing, as well as the beam divergence and energy variation across the field. The modified source model was benchmarked against standard depth dose and profile measurements, and the agreement between the calculation and measurement is within the AAPM Task Group No. 53 criteria for all benchmark fields used. Film dosimetry was used to evaluate the model for IMRT sequences and plans, and the ability of the model to account for leaf sequencing effects is also demonstrated. (C) 2002 American Association of Physicists in Medicine.
引用
收藏
页码:2952 / 2958
页数:7
相关论文
共 27 条
[1]  
AGAZARYAN N, 1999, MED PHYS, V26, P1139
[2]   MONTE-CARLO TECHNIQUES IN MEDICAL RADIATION PHYSICS [J].
ANDREO, P .
PHYSICS IN MEDICINE AND BIOLOGY, 1991, 36 (07) :861-920
[3]  
[Anonymous], 2010, XCOM PHOTON CROSS SE
[4]   A method for determining multileaf collimator transmission and scatter for dynamic intensity modulated radiotherapy [J].
Arnfield, MR ;
Siebers, JV ;
Kim, JO ;
Wu, QW ;
Keall, PJ ;
Mohan, R .
MEDICAL PHYSICS, 2000, 27 (10) :2231-2241
[5]   X-RAY FIELD COMPENSATION WITH MULTILEAF COLLIMATORS [J].
BORTFELD, TR ;
KAHLER, DL ;
WALDRON, TJ ;
BOYER, AL .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1994, 28 (03) :723-730
[6]  
Briesmeister JF., 1997, ALAMOS NATL LAB REPO, pLA
[7]   MONTE-CARLO STUDY OF ACCELERATOR HEAD SCATTER [J].
CHANEY, EL ;
CULLIP, TJ ;
GABRIEL, TA .
MEDICAL PHYSICS, 1994, 21 (09) :1383-1390
[8]   A virtual source model for Monte Carlo modeling of arbitrary intensity distributions [J].
Chetty, I ;
DeMarco, JJ ;
Solberg, TD .
MEDICAL PHYSICS, 2000, 27 (01) :166-172
[9]  
Chetty L, 2000, RADIOSURG, V3, P41
[10]   Commissioning of a micro multi-leaf collimator and planning system for stereotactic radiosurgery [J].
Cosgrove, VP ;
Jahn, U ;
Pfaender, M ;
Bauer, S ;
Budach, V ;
Wurm, RE .
RADIOTHERAPY AND ONCOLOGY, 1999, 50 (03) :325-336