Flow injection manifold for the direct spectrophotometric determination of bismuth in pharmaceutical products using Methylthymol Blue as a chromogenic reagent

被引:21
作者
Themelis, DG [1 ]
Tzanavaras, PD [1 ]
Papadimitriou, JK [1 ]
机构
[1] Aristotelian Univ Salonika, Dept Chem, Analyt Chem Lab, GR-54006 Salonika, Greece
关键词
D O I
10.1039/b008661o
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A new simple and rapid flow injection method is reported for the direct determination of bismuth in pharmaceutical products. Methylthymol Blue (MTB) was used as a chromogenic reagent and the absorbance of the colored Bi(iii)-MTB complex produced was monitored at 548 nm. The various chemical and physical variables were optimized and a study of interfering ions was also carried out. Linear calibration graphs were obtained from 0 to 100 mg l(-1) Bi(iii) (120 injections per hour). The precision was very good (s(r) = 1.3%) and the limit of detection was c(L) = 0.150 mg l(-1). The average accuracy was also very good (e(r) = 0.75%) and was evaluated by comparison of the results obtained with those claimed by the manufacturers. The method was found to be adequately selective, considering the ions that the samples contain.
引用
收藏
页码:247 / 250
页数:4
相关论文
共 15 条
[1]   Determination of bismuth in pharmaceutical products using liquid-liquid extraction in a flow injection system [J].
Alonso, A ;
Almendral, MJ ;
Báez, MD ;
Porras, MJ ;
Lávin, FL ;
de María, CG .
ANALYTICA CHIMICA ACTA, 2000, 408 (1-2) :129-133
[2]   EXTRACTION AND SPECTROPHOTOMETRIC DETERMINATION OF BISMUTH(III) WITH CYANEX-301 [J].
ARGEKAR, AP ;
SHETTY, AK .
ANALYST, 1995, 120 (06) :1819-1822
[3]   Determination of bismuth in biological samples using on-line flow-injection microwave-assisted mineralization and precipitation/dissolution for electrothermal atomic absorption spectrometry [J].
Burguera, JL ;
Burguera, M ;
Rivas, C ;
Rondon, C ;
Carrero, P ;
Gallignani, M .
TALANTA, 1999, 48 (04) :885-893
[4]   The spectrophotometric determination of bismuth after extraction of protriptylinium tetraiodobismuthate(III) [J].
Burns, DT ;
Dunford, MD .
ANALYTICA CHIMICA ACTA, 1996, 334 (1-2) :209-211
[5]   Spectrophotometric determination of bismuth in pharmaceutical samples by extraction of the tetraiodobismuthate(III) anion into propylene carbonate [J].
Burns, DT ;
Dangolle, CDP .
ANALYTICA CHIMICA ACTA, 1997, 337 (01) :113-116
[6]  
BURNS DT, 1989, ANAL CHIM ACTA, V225, P449
[7]   Spectrophotometric determination of bismuth after extraction of tetrabutylammonium tetraiodobismuthate(III) with microcrystalline benzophenone [J].
Burns, DT ;
Tungkananuruk, N ;
Thuwasin, S .
ANALYTICA CHIMICA ACTA, 2000, 419 (01) :41-44
[8]  
ENOKI T, 1969, BUNSEKI KAGAKU, V18, P963
[9]  
*EUR AG EV MED PRO, 1997, VET MED EV UN
[10]   SPECTROPHOTOMETRIC DETERMINATION OF BISMUTH IN PHARMACEUTICAL PREPARATIONS USING MUCIC ACID [J].
GONZALEZPORTAL, A ;
BALUJASANTOS, C ;
BERMEJOMARTINEZ, F .
ANALYST, 1986, 111 (05) :547-549