Real-time fiber-based multi-functional spectral-domain optical coherence tomography at 1.3 μm

被引:286
作者
Park, BH
Pierce, MC
Cense, B
Yun, SH
Mujat, M
Tearney, GJ
Bouma, BE
de Boer, JF
机构
[1] Harvard Univ, Sch Med, Boston, MA 02114 USA
[2] Wellman Ctr Photomed, Boston, MA 02114 USA
来源
OPTICS EXPRESS | 2005年 / 13卷 / 11期
关键词
D O I
10.1364/OPEX.13.003931
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
We demonstrate a high- speed multi- functional spectral- domain optical coherence tomography system, using a broadband light source centered at 1.3 mu m and two InGaAs line scan cameras capable of acquiring individual axial scans in 24.4 mu s, at a rate of 18,500 axial scans per second. Fundamental limitations on the accuracy of phase determination as functions of signal- to- noise ratio and lateral scan speed are presented and their relative contributions are compared. The consequences of phase accuracy are discussed for both Doppler and polarization- sensitive OCT measurements. A birefringence artifact and a calibration procedure to remove this artifact are explained. Images of a chicken breast tissue sample acquired with the system were compared to those taken with a time- domain OCT system for birefringence measurement verification. The ability of the system to image pulsatile flow in the dermis and to perform functional imaging of large volumes demonstrates the clinical potential of multifunctional spectral- domain OCT. (C) 2005 Optical Society of America.
引用
收藏
页码:3931 / 3944
页数:14
相关论文
共 40 条
[1]  
Andretzky P, 1998, P SOC PHOTO-OPT INS, V3567, P78
[2]   High-resolution imaging of the human esophagus and stomach in vivo using optical coherence tomography [J].
Bouma, BE ;
Tearney, GJ ;
Compton, CC ;
Nishioka, NS .
GASTROINTESTINAL ENDOSCOPY, 2000, 51 (04) :467-474
[3]   In vivo depth-resolved birefringence measurements of the human retinal nerve fiber layer by polarization-sensitive optical coherence tomography [J].
Cense, B ;
Chen, TC ;
Park, BH ;
Pierce, MC ;
de Boer, JF .
OPTICS LETTERS, 2002, 27 (18) :1610-1612
[4]   Optical Doppler tomographic imaging of fluid flow velocity in highly scattering media [J].
Chen, ZP ;
Milner, TE ;
Dave, D ;
Nelson, JS .
OPTICS LETTERS, 1997, 22 (01) :64-66
[5]   Sensitivity advantage of swept source and Fourier domain optical coherence tomography [J].
Choma, MA ;
Sarunic, MV ;
Yang, CH ;
Izatt, JA .
OPTICS EXPRESS, 2003, 11 (18) :2183-2189
[6]   Improved signal-to-noise ratio in spectral-domain compared with time-domain optical coherence tomography [J].
de Boer, JF ;
Cense, B ;
Park, BH ;
Pierce, MC ;
Tearney, GJ ;
Bouma, BE .
OPTICS LETTERS, 2003, 28 (21) :2067-2069
[7]   MEASUREMENT OF INTRAOCULAR DISTANCES BY BACKSCATTERING SPECTRAL INTERFEROMETRY [J].
FERCHER, AF ;
HITZENBERGER, CK ;
KAMP, G ;
ELZAIAT, SY .
OPTICS COMMUNICATIONS, 1995, 117 (1-2) :43-48
[8]   Imaging caries lesions and lesion progression with polarization sensitive optical coherence tomography [J].
Fried, D ;
Xie, J ;
Shafi, S ;
Featherstone, JDB ;
Breunig, TM ;
Le, C .
JOURNAL OF BIOMEDICAL OPTICS, 2002, 7 (04) :618-627
[9]  
Häusler G, 1998, J BIOMED OPT, V3, P21, DOI 10.1117/1.429899
[10]   OPTICAL COHERENCE TOMOGRAPHY [J].
HUANG, D ;
SWANSON, EA ;
LIN, CP ;
SCHUMAN, JS ;
STINSON, WG ;
CHANG, W ;
HEE, MR ;
FLOTTE, T ;
GREGORY, K ;
PULIAFITO, CA ;
FUJIMOTO, JG .
SCIENCE, 1991, 254 (5035) :1178-1181