Optimization of solid phase extraction clean up and validation of quantitative determination of corticosteroids in urine by liquid chromatography-tandem mass spectrometry

被引:58
作者
Andersen, Jens Hinge [1 ]
Hansen, Lene Gram [1 ]
Pedersen, Mikael [1 ]
机构
[1] Tech Univ Denmark, Natl Food Inst, DK-2860 Soborg, Denmark
关键词
corticosteroids; liquid chromatography-tandem mass spectrometry; validation; urine; ion-suppression;
D O I
10.1016/j.aca.2008.02.070
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A solid phase extraction (SPE) method for extraction and clean up of 9 synthetic corticosteroids was optimized for quantification by reversed-phase high-performance liquid chromatography/negative electrospray ionisation mass spectrometry. Clean up was accomplished using a mixed mode polymeric strong anion exchange SPE column. The final method was validated according to EU regulations for determination of residues of veterinarian drugs in products of animal origin. Initial results showed a large difference in ion suppression between samples of porcine and bovine urine. The aim of optimisation was to design a procedure that minimised this difference while using a single SPE procedure and a fast HPLC method that enabled sufficient separation of the epimers beta- and dexamethason. To include conjugated corticosteroids in the analysis, the sample was hydrolysed with Helix Pomatia beta-glucuronidase/aryl sulfatase. For the final method, which included fluocinolone acetonid, triamcinolone acetonid, beclomethasone, flumethasone, dexamethasone, betamethasone, 6 alpha-methylprednisolone, prednisone and prednisolone, a quantification based on spiked samples carried through the entire analytical procedure was used. For quantification of triamcinolone acetonid an internal standard (triamcinolon acetonid-D6) was used. Relative average recoveries from 96 to 103% were found, except for beclomethason (113%). Absolute average recoveries were 81-99%. Quantification limits (decision limits, CC alpha) were demonstrated to be not higher than 1 mu g L-1 (3 mu g L-1 for prednisone and prednisolone). The internal reproducibility, determined by triplicates from spiking at three different levels in six analytical series was 7-19% (at 2-4 mu gL(-1)) except for prednisone and prednisolone (26-27% at 3-6 mu gL(-1)). (C) 2008 Elsevier B.V. All rights reserved.
引用
收藏
页码:216 / 224
页数:9
相关论文
共 12 条
[1]  
[Anonymous], OFF J EUR COMM
[2]   Multi-residue extraction-purification procedure for corticosteroids in biological samples for efficient control of their misuse in livestock production [J].
Antignac, JP ;
Le Bizec, B ;
Monteau, F ;
Poulain, F ;
Andre, F .
JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2001, 757 (01) :11-19
[3]   Effect of liquid chromatography separation of complex matrices on liquid chromatography-tandem mass spectrometry signal suppression [J].
Choi, BK ;
Hercules, DM ;
Gusev, AI .
JOURNAL OF CHROMATOGRAPHY A, 2001, 907 (1-2) :337-342
[4]  
*DAN MED AG, DAT APPR DRUGS VET U
[5]   Validation of a screening method for corticosteroids in doping analysis by liquid chromatography/tandem mass spectrometry [J].
Deventer, K ;
Delbeke, FT .
RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 2003, 17 (18) :2107-2114
[6]  
*EMEA, 1999, EMEAMRL62999
[7]   Comprehensive screening of anabolic steroids, corticosteroids, and acidic drugs in horse urine by solid-phase extraction and liquid chromatography-mass spectrometry [J].
Ho, Emmie N. M. ;
Leung, David K. K. ;
Wan, Terence S. M. ;
Yu, Nola H. .
JOURNAL OF CHROMATOGRAPHY A, 2006, 1120 (1-2) :38-53
[8]   High-throughput screening of corticosteroids and basic drugs in horse urine by liquid chromatography-tandem mass spectrometry [J].
Leung, GNW ;
Chung, EW ;
Ho, ENM ;
Kwok, WH ;
Leung, DKK ;
Tang, FPW ;
Wan, TSM ;
Yu, NH .
JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2005, 825 (01) :47-56
[9]   Strategies for the assessment of matrix effect in quantitative bioanalytical methods based on HPLC-MS/MS [J].
Matuszewski, BK ;
Constanzer, ML ;
Chavez-Eng, CM .
ANALYTICAL CHEMISTRY, 2003, 75 (13) :3019-3030
[10]  
MEI H, 2004, USING MASS SPECTROME