Fifteen years experience with finger arterial pressure monitoring: assessment of the technology

被引:654
作者
Imholz, BPM
Wieling, W
van Montfrans, GA
Wesseling, KH
机构
[1] Univ Amsterdam, Acad Med Ctr, Dept Internal Med, NL-1105 AZ Amsterdam, Netherlands
[2] Univ Amsterdam, Acad Med Ctr, TNO, NL-1105 AZ Amsterdam, Netherlands
关键词
Finapres; technology assessment; accuracy; precision; tracking ability;
D O I
10.1016/S0008-6363(98)00067-4
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
We review the Finapres technology, embodied in several TNO-prototypes and in the Ohmeda 2300 and 2300e Finapres NIBP. Finapres is an acronym for FINger Arterial PRESsure, the device delivers a continuous finger arterial pressure waveform. Many papers report on the accuracy of the device in comparison with intra-arterial or with noninvasive but intermittent blood pressure measurements. We compiled the results of 43 such papers and found systolic, diastolic and mean accuracies, in this order, ranging from -48 to 30 mmHg, from -20 to 18 mmHg, and from -13 to 25 mmHg. Weighted for the number of subjects included pooled accuracies were -0.8 (SD 11.9), -1.6 (8.3) and -1.6 (7.6) mmHg respectively. Subdividing the pooled group according to criteria such as reference blood pressure, place of application, and prototype or commercial device we found no significant differences in mean differences or SD. Measurement at the finger allows uninterrupted recordings of long duration. The transmission of the pressure pulse along the arm arteries, however, causes distortion of the pulse waveform and depression of the mean blood pressure level. These effects can be reduced by appropriate filtering, and upper arm 'return-to-flow' calibration to bring accuracy and precision within AAMI limits. For the assessment of beat-to-beat changes in blood pressure and assessment of blood pressure variability Finapres proved a reliable alternative for invasive measurements when mean and diastolic pressures are concerned. Differences in systolic pressure are larger and reach statistical significance but are not of clinical relevance. Finger arteries are affected by contraction and dilatation in relation to psychological and physical (heat, cold, blood loss, orthostasis) stress. Effects of these phenomena are reduced by the built-in Physiocal algorithm. However, full smooth muscle contraction should be avoided in the awake patient by comforting the patient, and covering the hand. Arterial state can be monitored by observing the behaviour of the Physiocal algorithm. We conclude that Finapres accuracy and precision usually suffice for reliable tracking of changes in blood pressure. Diagnostic accuracy may be achieved with future application of corrective measures. (C) 1998 Elsevier Science B.V. AU rights reserved.
引用
收藏
页码:605 / 616
页数:12
相关论文
共 85 条
[11]  
DEMEY C, 1995, BRIT J CLIN PHARMACO, V40, P291
[12]   EFFECTS OF PERIPHERAL VASOCONSTRICTION ON THE BLOOD-PRESSURE IN THE FINGER, MEASURED CONTINUOUSLY BY A NEW NONINVASIVE METHOD (THE FINAPRES) [J].
DORLAS, JC ;
NIJBOER, JA ;
BUTIJN, WT ;
VANDERHOEVEN, GMA ;
SETTELS, JJ ;
WESSELING, KH .
ANESTHESIOLOGY, 1985, 62 (03) :342-345
[13]   CONTINUOUS NONINVASIVE FINGER BLOOD-PRESSURE DURING CONTROLLED HYPOTENSION - A COMPARISON WITH INTRAARTERIAL PRESSURE [J].
EPSTEIN, RH ;
BARTKOWSKI, RR ;
HUFFNAGLE, S .
ANESTHESIOLOGY, 1991, 75 (05) :796-803
[14]   COMPARATIVE ACCURACIES OF A FINGER BLOOD-PRESSURE MONITOR AND AN OSCILLOMETRIC BLOOD-PRESSURE MONITOR [J].
EPSTEIN, RH ;
HUFFNAGLE, S ;
BARTKOWSKI, RR .
JOURNAL OF CLINICAL MONITORING, 1991, 7 (02) :161-167
[15]   EVALUATION OF A CONTINUOUS NONINVASIVE BLOOD-PRESSURE MONITOR IN OBSTETRIC PATIENTS UNDERGOING SPINAL-ANESTHESIA [J].
EPSTEIN, RH ;
KAPLAN, S ;
LEIGHTON, BL ;
NORRIS, MC ;
DESIMONE, CA .
JOURNAL OF CLINICAL MONITORING, 1989, 5 (03) :157-163
[16]   CONTINUOUS DIRECT AND INDIRECT BLOOD-PRESSURE MEASUREMENT (FINAPRES) IN THE CRITICALLY ILL [J].
FARQUHAR, IK .
ANAESTHESIA, 1991, 46 (12) :1050-1055
[17]   NONINVASIVE BLOOD-PRESSURE MONITORING DURING HEAD-UP TILT USING THE PENAZ PRINCIPLE [J].
FRIEDMAN, DB ;
JENSEN, FB ;
MATZEN, S ;
SECHER, NH .
ACTA ANAESTHESIOLOGICA SCANDINAVICA, 1990, 34 (07) :519-522
[18]   NONINVASIVE VS INVASIVE BEAT-TO-BEAT MONITORING OF BLOOD-PRESSURE [J].
GABRIEL, A ;
LINDBLAD, LE ;
ANGLERYD, C .
CLINICAL PHYSIOLOGY, 1992, 12 (02) :229-235
[19]   THE ACCURACY OF FINAPRES NONINVASIVE MEAN ARTERIAL-PRESSURE MEASUREMENTS IN ANESTHETIZED PATIENTS [J].
GIBBS, NM ;
LARACH, DR ;
DERR, JA .
ANESTHESIOLOGY, 1991, 74 (04) :647-652
[20]  
GIZDULICH P, 1995, HOMEOSTASIS HLTH DIS, V36, P120