Optical bioimaging: From living tissue to a single molecule: Imaging and functional analysis of blood flow in organic microcirculation

被引:15
作者
Minamitani, H [1 ]
Tsukada, K
Sekizuka, E
Oshio, C
机构
[1] Keio Univ, Grad Sch Sci & Technol, Inst Biomed Engn, Yokohama, Kanagawa 2230061, Japan
[2] Kawasaki Med Sch, Dept Physiol, Kurashiki, Okayama 7010192, Japan
[3] Natl Saitama Hosp, Wako, Saitama 3510102, Japan
[4] Oshio Clin, Chiyoda Ku, Tokyo 1010063, Japan
关键词
microcirculation; erythrocyte deformability; hemostasis; active oxygen; image analysis;
D O I
10.1254/jphs.93.227
中图分类号
R9 [药学];
学科分类号
1007 ;
摘要
Activity of blood cells, erythrocytes, leucocytes, and platelets, in microcirculation was observed by using an intravital microscope and confocal laser scanning microscope connected with an image processing system including fluorescence and phosphorescence emission methods. Dynamic functions of the blood flow were mainly observed in mesentery, brain, and liver tissues of rats. The results are summarized as follows: Deformability of diabetic erythrocytes was significantly lower than that of healthy controls, particularly at high shear rate. The spring constant and Young's modulus of diabetic erythrocytes obviously stiffened, making them hard to deform in the capillary. During hemorrhagic shock and thrombosis, flow velocity and oxygen partial pressure of blood decreased in the brain and liver tissues that can be visualized by using FITC stained erythrocytes and Pd-porphyrin derivative as a pO(2) probe. Platelet adhesion and thrombus formation in the micro-vessels accelerated under the photodynamic reaction; diabetic platelets showed augmented adhesion and aggregation on the vessel wall which was followed by acute thromboembolism. Active oxygen radicals take part in thrombus formation, accompanied with adhesion of the activated leucocytes. Fluorescent dye probes, rhodamine G and acridine orange, are quite useful for visualization of the flow behavior of platelets and leucocytes, respectively.
引用
收藏
页码:227 / 233
页数:7
相关论文
共 10 条
  • [1] FILHO IPT, 1993, AM J PHYSIOL, V265, pH1434
  • [2] VARIATION IN RED-BLOOD-CELL DEFORMABILITY AND POSSIBLE CONSEQUENCES FOR OXYGEN-TRANSPORT TO TISSUE
    KIKUCHI, Y
    DA, QW
    FUJINO, T
    [J]. MICROVASCULAR RESEARCH, 1994, 47 (02) : 222 - 231
  • [3] REDUCED ERYTHROCYTE DEFORMABILITY IN DIABETES
    MCMILLAN, DE
    UTTERBACK, NG
    LAPUMA, J
    [J]. DIABETES, 1978, 27 (09) : 895 - 901
  • [4] Analysis of elasticity and deformability of erythrocytes using micro-channel flow system and atomic force microscope
    Minamitani, H
    Tsukada, K
    Kawamura, T
    Sekizuka, E
    Oshio, C
    [J]. 1ST ANNUAL INTERNATIONAL IEEE-EMBS SPECIAL TOPIC CONFERENCE ON MICROTECHNOLOGIES IN MEDICINE & BIOLOGY, PROCEEDINGS, 2000, : 68 - 71
  • [5] Oxygen tension gradients and heterogeneity in venous microcirculation: A phosphorescence quenching study
    Shonat, RD
    Johnson, PC
    [J]. AMERICAN JOURNAL OF PHYSIOLOGY-HEART AND CIRCULATORY PHYSIOLOGY, 1997, 272 (05): : H2233 - H2240
  • [6] Stern O, 1919, PHYS Z, V20, P183
  • [7] STUART J, 1983, CLIN HEMORHEOL, V3, P23
  • [8] A SILICON MICROMACHINED DEVICE FOR USE IN BLOOD-CELL DEFORMABILITY STUDIES
    TRACEY, MC
    GREENAWAY, RS
    DAS, A
    KAYE, PH
    BARNES, AJ
    [J]. IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 1995, 42 (08) : 751 - 761
  • [9] Image correlation method for measuring blood flow velocity in microcirculation:: correlation 'window' simulation and in vivo image analysis
    Tsukada, K
    Minamitani, H
    Sekizuka, E
    Oshio, C
    [J]. PHYSIOLOGICAL MEASUREMENT, 2000, 21 (04) : 459 - 471
  • [10] Direct measurement of erythrocyte deformability in diabetes mellitus with a transparent microchannel capillary model and high-speed video camera system
    Tsukada, K
    Sekizuka, E
    Oshio, C
    Minamitani, H
    [J]. MICROVASCULAR RESEARCH, 2001, 61 (03) : 231 - 239