Nickel oxide microfibers immobilized onto electrode by electrospinning and calcination for nonenzymatic glucose sensor and effect of calcination temperature on the performance

被引:127
作者
Cao, Fei [1 ]
Guo, Shu [1 ]
Ma, Huiyan [1 ]
Shan, Decai [1 ]
Yang, Shengxue [1 ]
Gong, Jian [1 ]
机构
[1] NE Normal Univ, Key Lab Polyoxometalates Sci, Minist Educ, Changchun 130024, Jilin, Peoples R China
关键词
Nickel oxide microfibers; Electrospinning; Calcination temperature; Glucose; Nonenzymatic sensor; BIOSENSORS; OXIDATION; ELECTROOXIDATION; NANOWIRES;
D O I
10.1016/j.bios.2010.10.013
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
Nickel oxide microfibers (NiO-MFs) were directly immobilized onto the surface of fluorine tin oxide (FTO) electrode by electrospinning and calcination without using any immobilization matrix for nonenzymatic glucose sensor. Morphology and structure of NiO-MEs were characterized by scanning electron microscopy (SEM), energy dispersive X-ray spectroscopy (EDX), and X-ray diffraction pattern (XRD). The electrochemical and electrocatalytic performances of the NiO-MEs modified electrodes prepared at different calcination temperatures ranging from 300 to 500 degrees C were evaluated by cyclic voltammetry (CV). The CV results have demonstrated that NiO-MEs modified electrode prepared at 300 degrees C displayed distinct increase in electrocatalytic activity toward the oxidation of glucose, which is explored to develop an amperometric nonenzymatic glucose sensor. The NiO-MEs prepared at 300 degrees C based amperometric nonenzymatic glucose sensor has ultrasensitive current (1785.41 mu A mM(-1) cm(-2)) response and low detection limit of 3.3 x 10(-8) M (signal/noise ratio (S/N) = 3), which are among the best values reported in literature. Additionally, excellent selectivity and stability have also been obtained. (c) 2010 Elsevier B.V. All rights reserved.
引用
收藏
页码:2756 / 2760
页数:5
相关论文
共 26 条
[1]   Electrical and optical properties of narrow-band materials [J].
Adler, David ;
Feinleib, Julius .
PHYSICAL REVIEW B-SOLID STATE, 1970, 2 (08) :3112-3134
[2]   ELECTROCHEMICAL OXIDATION OF GLUCOSE ON SINGLE-CRYSTAL GOLD SURFACES [J].
ADZIC, RR ;
HSIAO, MW ;
YEAGER, EB .
JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 1989, 260 (02) :475-485
[3]   ELECTROOXIDATION OF ALCOHOLS AND SUGARS CATALYZED ON A NICKEL-OXIDE MODIFIED GLASSY-CARBON ELECTRODE [J].
BERCHMANS, S ;
GOMATHI, H ;
RAO, GP .
JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 1995, 394 (1-2) :267-270
[4]   Nonenzymatic electrochemical glucose sensor based on MnO2/MWNTs nanocomposite [J].
Chen, Jin ;
Zhang, Wei-De ;
Ye, Jian-Shan .
ELECTROCHEMISTRY COMMUNICATIONS, 2008, 10 (09) :1268-1271
[5]   Electrospun hemoglobin microbelts based biosensor for sensitive detection of hydrogen peroxide and nitrite [J].
Ding, Yu ;
Wang, Ying ;
Li, Baikun ;
Lei, Yu .
BIOSENSORS & BIOELECTRONICS, 2010, 25 (09) :2009-2015
[6]   Preparation and characterization of H4SiMo12O40/poly(vinyl alcohol) fiber mats produced by an electrospinning method [J].
Gong, J ;
Li, XD ;
Ding, B ;
Lee, DR ;
Kim, HY .
JOURNAL OF APPLIED POLYMER SCIENCE, 2003, 89 (06) :1573-1578
[7]   Preparation and characterization of NiO nanofibres via an electrospinning technique [J].
Guan, HY ;
Shao, CL ;
Wen, SB ;
Chen, B ;
Gong, J ;
Yang, XH .
INORGANIC CHEMISTRY COMMUNICATIONS, 2003, 6 (10) :1302-1303
[8]   Electrocatalytic oxidation and determination of deferasirox and deferiprone on a nickel oxyhydroxide-modified electrode [J].
Hajjizadeh, M. ;
Jabbari, A. ;
Heli, H. ;
Moosavi-Movahedi, A. A. ;
Shafiee, A. ;
Karimian, K. .
ANALYTICAL BIOCHEMISTRY, 2008, 373 (02) :337-348
[9]   CHARACTERIZATION AND STABILIZATION OF ENZYME BIOSENSORS [J].
KATAKIS, I ;
DOMINGUEZ, E .
TRAC-TRENDS IN ANALYTICAL CHEMISTRY, 1995, 14 (07) :310-319
[10]   Effect of heat treatment on the oxygen content and resistivity in sputtered NiO films [J].
Kohmoto, O ;
Nakagawa, H ;
Isagawa, Y ;
Chayahara, A .
JOURNAL OF MAGNETISM AND MAGNETIC MATERIALS, 2001, 226 (PART II) :1629-1630