Mechanical behavior, wear surface morphology, and clinical performance of UHMWPE acetabular components after 10 years of implantation

被引:53
作者
Edidin, AA
Rimnac, CM
Goldberg, VM
Kurtz, SM
机构
[1] Howmedica Osteon Corp, Allendale, NJ USA
[2] Exponent Inc, Philadelphia, PA USA
[3] Drexel Univ, Sch Biomed Engn Sci & Hlth Syst, Implant Res Ctr, Philadelphia, PA 19104 USA
[4] Thomas Jefferson Univ, Dept Orthopaed Surg, Philadelphia, PA 19107 USA
[5] Case Western Reserve Univ, Orthopaed Implant Retrieval Anal Lab, Dept Orthopaed, Cleveland, OH 44106 USA
[6] Case Western Reserve Univ, Orthopaed Implant Retrieval Anal Lab, Dept Mech & Aerosp Engn, Cleveland, OH 44106 USA
关键词
ultra-high molecular weight polyethylene (UHMWPE); acetabular component; total hip replacement; wear; surface morphology; surface roughness; mechanical behavior;
D O I
10.1016/S0043-1648(01)00616-0
中图分类号
TH [机械、仪表工业];
学科分类号
0802 ;
摘要
The relationships between the mechanical behavior of ultra-high molecular weight polyethylene (UHMWPE) and the long-term clinical performance of acetabular component bearings remain poorly understood. During previous hip simulator validation studies, researchers have correlated the mechanical behavior and surface morphology of polymeric biomaterials with the wear performance in a hip simulator. For the present study, we sought correlations between clinical performance and quantitative metrics of the mechanical behavior and surface morphology of retrieved cups. Nine all-UHMWPE acetabular cups of the same cemented design, 32 mm head size, and manufacturer were retrieved after an average implantation time of 14.1 years (range: 11.5-16.4 years). The implants were manufactured from RCH-1000, sterilized by gamma radiation in air and implanted between 1980 and 1983. Mechanical behavior of the retrieved components was determined using the previously validated small punch test, which subjects miniature specimens to multi-axial loading conditions. Surface morphology of the retrievals was assessed using white light interferometry. No significant relationship was observed between the surface roughness measurements and patient related variables. However, statistically significant relationships were observed between the mechanical behavior determined by the small punch test and the implantation time and patient weight associated with the retrieved hip cups. These findings support the hypothesis that the mechanical behavior of UHMWPE is related, at least in part, to the clinical performance of acetabular component bearings for total hip replacement. (C) 2001 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:152 / 158
页数:7
相关论文
共 42 条
[1]   THE EFFECT OF CONFORMITY, THICKNESS, AND MATERIAL ON STRESSES IN ULTRAHIGH MOLECULAR-WEIGHT COMPONENTS FOR TOTAL JOINT REPLACEMENT [J].
BARTEL, DL ;
BICKNELL, VL ;
WRIGHT, TM .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1986, 68A (07) :1041-1051
[2]  
Bhushan B., 1999, Principles and Applications of Tribology
[3]  
Bragdon C R, 1996, Proc Inst Mech Eng H, V210, P157, DOI 10.1243/PIME_PROC_1996_210_408_02
[4]   MACROSCOPIC AND MICROSCOPIC WEAR MECHANISMS IN ULTRA-HIGH-MOLECULAR-WEIGHT POLYETHYLENE [J].
COOPER, JR ;
DOWSON, D ;
FISHER, J .
WEAR, 1993, 162 :378-384
[5]   Degradation of mechanical behavior in UHMWPE after natural and accelerated aging [J].
Edidin, AA ;
Jewett, CW ;
Kalinowski, A ;
Kwarteng, K ;
Kurtz, SM .
BIOMATERIALS, 2000, 21 (14) :1451-1460
[6]   Influence of mechanical behavior on the wear of 4 clinically relevant polymeric biomaterials in a hip simulator [J].
Edidin, AA ;
Kurtz, SM .
JOURNAL OF ARTHROPLASTY, 2000, 15 (03) :321-331
[7]   Plasticity-induced damage layer is a precursor to wear in radiation-cross-linked UHMWPE acetabular components for total hip replacement [J].
Edidin, AA ;
Pruitt, L ;
Jewett, CW ;
Crane, DJ ;
Roberts, D ;
Kurtz, SM .
JOURNAL OF ARTHROPLASTY, 1999, 14 (05) :616-627
[8]  
Elfick APD, 1999, J BIOMED MATER RES, V48, P712, DOI 10.1002/(SICI)1097-4636(1999)48:5<712::AID-JBM17>3.0.CO
[9]  
2-R
[10]  
Fisher J, 1991, Proc Inst Mech Eng H, V205, P73, DOI 10.1243/PIME_PROC_1991_205_271_02