Construction of an amperometric pyruvate oxidase enzyme electrode for determination of pyruvate and phosphate

被引:46
作者
Akyilmaz, Erol [1 ]
Yorganci, Emine [1 ]
机构
[1] Ege Univ, Fac Sci, Dept Biochem, TR-35100 Bornova, Turkey
关键词
pyruvate; biosensor; phosphate; pyruvate oxidase; enzyme electrode;
D O I
10.1016/j.electacta.2007.06.058
中图分类号
O646 [电化学、电解、磁化学];
学科分类号
081704 [应用化学];
摘要
In this study an amperometric biosensor based on pyruvate oxidase was developed for the determination of pyruvate and phosphate. For construction of the biosensor pyruvate oxidase was immobilized with gelatin and insolubilized in film by forming cross-linked bonds with glutaraldehyde. The film was fixed on a YSI type dissolved oxygen (DO) probe, covered with a teflon membrane which is high-sensitive for oxygen. The working principle of the biosensor depends on detection of consumed DO concentration related to pyruvate concentration which is used in enzymatic reaction catalyzed by pyruvate oxidase. The biosensor response shows a linearity with pyruvate concentration between 0.0025 and 0.05 mu M and also response time of the biosensor is 3 min. In the optimization studies of the biosensor the most suitable enzyme activity was found as 2.5 U/cm(2) for pyruvate oxidase, and also phosphate buffer (pH 7.0; 50 mM) and 35 degrees C were established as providing the optimum working conditions. In the characterization studies of the biosensor some parameters such as reproducibility, substrate specificity, operational stability, determination of phosphate, and interference effects of some compounds on the pyruvate determination were investigated. Finally, the concentration of pyruvate was determined by using spectrophotometric method and the results obtained were compared to results obtained by the biosensor. (C) 2007 Elsevier Ltd. All rights reserved.
引用
收藏
页码:7972 / 7977
页数:6
相关论文
共 24 条
[1]
Pyruvate sensor based on pyruvate oxidase immobilized in a poly(mercapto-p-benzoquinone) film [J].
Arai, G ;
Noma, T ;
Habu, H ;
Yasumori, I .
JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 1999, 464 (02) :143-148
[2]
In vitro study of urease/AlaDH enzyme system encapsulated into human erythrocytes and research into its medical applications [J].
Baysal, SH ;
Uslan, AH .
ARTIFICIAL CELLS BLOOD SUBSTITUTES AND IMMOBILIZATION BIOTECHNOLOGY, 2002, 30 (01) :71-77
[3]
A bienzyme modified carbon paste electrode for amperometric detection of pyruvate [J].
Bergmann, W ;
Rudolph, R ;
Spohn, U .
ANALYTICA CHIMICA ACTA, 1999, 394 (2-3) :233-241
[4]
Chen WN, 1998, CIRC RES, V83, P898
[5]
Phosphate biosensor based on polyelectrolyte-stabilized pyruvate oxidase [J].
Gavalas, VG ;
Chaniotakis, NA .
ANALYTICA CHIMICA ACTA, 2001, 427 (02) :271-277
[6]
A novel biosensor system for the determination of phosphate [J].
Ikebukuro, K ;
Nishida, R ;
Yamamoto, H ;
Arikawa, Y ;
Nakamura, H ;
Suzuki, M ;
Kubo, I ;
Takeuchi, T ;
Karube, I .
JOURNAL OF BIOTECHNOLOGY, 1996, 48 (1-2) :67-72
[7]
EFFECTS OF PYRUVATE ON THE METABOLISM AND INSULIN-RESISTANCE OF OBESE ZUCKER RATS [J].
IVY, JL ;
CORTEZ, MY ;
CHANDLER, RM ;
BYRNE, HK ;
MILLER, RH .
AMERICAN JOURNAL OF CLINICAL NUTRITION, 1994, 59 (02) :331-337
[8]
The effects of pyruvate supplementation on body composition in overweight individuals [J].
Kalman, D ;
Colker, CM ;
Wilets, I ;
Roufs, JB ;
Antonio, J .
NUTRITION, 1999, 15 (05) :337-340
[9]
AMPEROMETRIC METHYLENE GREEN-MEDIATED PYRUVATE ELECTRODE BASED ON PYRUVATE OXIDASE ENTRAPPED IN CARBON PASTE [J].
KULYS, J ;
WANG, LZ ;
DAUGVILAITE, N .
ANALYTICA CHIMICA ACTA, 1992, 265 (01) :15-20
[10]
Amperometric biosensor for determining human salivary phosphate [J].
Kwan, RCH ;
Leung, HF ;
Hon, PYT ;
Cheung, HCF ;
Hirota, K ;
Renneberg, R .
ANALYTICAL BIOCHEMISTRY, 2005, 343 (02) :263-267