Determination of trace elements in filtered suspended marine particulate material by sector field HR-ICP-MS

被引:81
作者
Cullen, JT [1 ]
Field, MP [1 ]
Sherrell, RM [1 ]
机构
[1] Rutgers State Univ, Inst Marine & Coastal Sci, New Brunswick, NJ 08901 USA
关键词
D O I
10.1039/b104398f
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Quantification of particulate (>0.45 mum) and dissolved (<0.45 <rho>m) trace elements in seawater is imperative for understanding geochemical cycling in the marine environment. Suspended particulate trace element concentrations are typically <10% of total element concentrations in seawater. To overcome analytical difficulties associated with low analyte concentrations, it is common to filter large volumes (tens to thousands of litres) of seawater. We report a novel method for the rapid quantification of Al (324 ppb), P (159 ppb), V (2.02 ppb), Cr (2.85 ppb), Mn (22.3 ppb), Fe (304 ppb), Co (0.129 ppb), Ni (0.817 ppb), Cu (1.68 ppb), Zn (3.25 ppb), Mo (0.264 ppb), Ag (0.079 ppb), Cd (0.029 ppb), Ba (3.54 ppb), Pb (1.13 ppb) and U (0.053 ppb) in digest solutions of suspended matter, filtered from 0.2 to 5.0 L of seawater. Filter digest solutions, consisting of a complex matrix of filter residue, sea salt, dissolved solids and strong acids, are analyzed on the ELEMENT, a high resolution, inductively coupled plasma mass spectrometer (Finnigan-MAT, Bremen, Germany). High sensitivity (>1x10(6) counts s(-1) ppb(-1) In; with shielded torch) combined with low flow rates (mu Flow nebulizer, Elemental Scientific) provide excellent absolute detection limits (0.4 to 720 pg depending on the element). A resolution of 300 (low resolution) is appropriate for interference-free high mass analytes of interest (Ag, Cd, Pb, Ba and U), whereas 4300 (medium resolution) is sufficient to resolve all plasma-, water- and matrix-based polyatomic interferences on low mass analytes (Al, P and first row transition metals). The precision of the method is better than +/-4% for most analytes. Accuracy could not be determined conventionally using a certified reference material (not available), but was estimated from spiked samples to be <<plus/minus>4% when calculated using a standard additions curve and <<plus/minus>10% for most elements if using an external standard curve.
引用
收藏
页码:1307 / 1312
页数:6
相关论文
共 22 条
[11]   Direct determination of 10 trace metals in 50 μL samples of coastal seawater using desolvating micronebulization sector field ICP-MS [J].
Field, MP ;
Cullen, JT ;
Sherrell, RM .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 1999, 14 (09) :1425-1431
[12]  
GIEBMANN U, 1994, FRESEN J ANAL CHEM, V350, P186
[13]   Trace metals in suspended particulate matter of Atlantic Ocean surface water (40 degrees N to 20 degrees S) [J].
Helmers, E .
MARINE CHEMISTRY, 1996, 53 (1-2) :51-67
[14]  
Jarvis K. E., 1992, HDB INDUCTIVELY COUP, DOI [10.1007/BF02290251, DOI 10.1007/BF02290251]
[15]   Spatial variability of particle associated trace elements in near-surface waters of the North Atlantic (30°N/60°W to 60°N/2°W), derived by large-volume sampling [J].
Kuss, J ;
Kremling, K .
MARINE CHEMISTRY, 1999, 68 (1-2) :71-86
[16]   THE CONTRASTING BIOGEOCHEMISTRY OF IRON AND MANGANESE IN THE PACIFIC-OCEAN [J].
LANDING, WM ;
BRULAND, KW .
GEOCHIMICA ET COSMOCHIMICA ACTA, 1987, 51 (01) :29-43
[17]  
MARTIN JH, 1986, EARTH PLANET SCI LET
[18]   Speciation and microalgal bioavailability of inorganic silver [J].
Reinfelder, JR ;
Chang, SI .
ENVIRONMENTAL SCIENCE & TECHNOLOGY, 1999, 33 (11) :1860-1863
[19]   Non-spectral interferences caused by a saline water matrix in quadrupole and high resolution inductively coupled plasma mass spectrometry [J].
Rodushkin, I ;
Ruth, T ;
Klockare, D .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 1998, 13 (03) :159-166
[20]   Temporal variability of suspended mass and composition in the Northeast Pacific water column: relationships to sinking flux and lateral advection [J].
Sherrell, RM ;
Field, MP ;
Gao, Y .
DEEP-SEA RESEARCH PART II-TOPICAL STUDIES IN OCEANOGRAPHY, 1998, 45 (4-5) :733-761