Solid-phase FT-Raman determination of caffeine in energy drinks

被引:57
作者
Armenta, S [1 ]
Garrigues, S [1 ]
de la Guardia, M [1 ]
机构
[1] Univ Valencia, Dept Analyt Chem, E-46100 Burjassot, Valencia, Spain
关键词
caffeine; energy drink; FT-Raman; solid phase;
D O I
10.1016/j.aca.2005.05.032
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A solid-phase vibrational spectrometry-based methodology (solid-phase Fourier transform-Raman spectrometry, SP-FT-Raman) has been developed for caffeine determination in commercial energy drink samples. The Raman spectra of caffeine, fixed on a C18 solid phase packed into a glass tube of 5 mm i.d., was obtained directly between 3500 and 70 cm(-1). In order to quantify caffeine, Raman intensity between 573 and 542 cm(-1) corrected using a baseline defined between 580 and 540 cm(-1) was used. A repeatability of 3%, as relative standard deviation of five analysis of a 200 mg l(-1) concentration, and a limit of detection of 18 mg l(-1) were obtained. The SP-FT-Raman procedure provides a sampling frequency of 13.3 h(-1), higher than that of liquid chromatography (LC), which was 7.0 h(-1). The use of FT-Raman reduces the reagent consumption and waste generation, also minimizing the sample handling. Results obtained by the developed procedure were statistically comparable with those found by a reference LC method. (c) 2005 Elsevier B.V. All rights reserved.
引用
收藏
页码:197 / 203
页数:7
相关论文
共 23 条
[11]  
Lima JLFC, 1998, FOOD ADDIT CONTAM, V15, P265, DOI 10.1080/02652039809374640
[12]  
Lin HJ, 2000, J FOOD DRUG ANAL, V8, P180
[13]   Simultaneous determination of ingredients in a vitamin-enriched drink by micellar electrokinetic chromatography [J].
Okamoto, H ;
Nakajima, T ;
Ito, Y .
JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2002, 30 (03) :815-822
[14]   Solid phase Fourier transform near infrared spectroscopy [J].
Ortega-Barrales, P ;
Ayora-Cañada, MJ ;
Molina-Díaz, A ;
Garrigues, S ;
de la Guardia, M .
ANALYST, 1999, 124 (04) :579-582
[15]   Raman spectroscopy of natural silica in Chicxulub impactite, Mexico [J].
Ostroumov, M ;
Faulques, E ;
Lounejeva, E .
COMPTES RENDUS GEOSCIENCE, 2002, 334 (01) :21-26
[16]   A rapid FTIR spectroscopic method for estimation of caffeine in soft drinks and total methylxanthines in tea and coffee [J].
Paradkar, MM ;
Irudayaraj, J .
JOURNAL OF FOOD SCIENCE, 2002, 67 (07) :2507-2511
[17]   Rapid determination of caffeine content in soft drinks using FTIR-ATR spectroscopy [J].
Paradkar, MM ;
Irudayaraj, J .
FOOD CHEMISTRY, 2002, 78 (02) :261-266
[18]   Solid-phase UV spectrophotometric method for determination of ciprofloxacin [J].
Pascual-Reguera, MI ;
Parras, GP ;
Díaz, AM .
MICROCHEMICAL JOURNAL, 2004, 77 (01) :79-84
[19]   Aquaporin and its function in boron uptake [J].
Ruiz, JM .
TRENDS IN PLANT SCIENCE, 2001, 6 (03) :95-95
[20]   A flow-through solid phase UV spectrophotometric biparameter sensor for the sequential determination of ascorbic acid and paracetamol [J].
Ruiz-Medina, A ;
Fernández-de Córdova, ML ;
Ayora-Cañada, MJ ;
Pascual-Reguera, MI ;
Molina-Díaz, A .
ANALYTICA CHIMICA ACTA, 2000, 404 (01) :131-139