Improved multi-elemental analyses by inductively coupled plasma-sector field mass spectrometry through methane addition to the plasma

被引:116
作者
Rodushkin, I [1 ]
Nordlund, P
Engström, E
Baxter, DC
机构
[1] Lulea Univ Technol, Div Appl Geol, S-97187 Lulea, Sweden
[2] Analyt AB, S-97187 Lulea, Sweden
关键词
D O I
10.1039/b507886e
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Changes in the analytical performance of double focusing sector field inductively coupled plasma mass spectrometry (ICP-SFMS) caused by addition of methane to the argon gas ICP were studied for approximately 100 isotopes of 70 elements. The parameters under consideration included instrumental background, analyte sensitivity, precision and formation of spectral interferences as functions of methane flow added to the sample gas. It was shown that for many analytes the capabilities of ICP-SFMS significantly improve by virtue of enhanced sensitivity and reduction of polyatomic interferences. In contrast to quadrupole-based ICP-MS, these gains in instrumental performance do not compromise multi-element capabilities given that the amount of methane is carefully optimized. The accuracy of the results for the determination of 50 elements in water samples was evaluated using the certified reference materials SLRS-4 and SLEW-2.
引用
收藏
页码:1250 / 1255
页数:6
相关论文
共 22 条
[1]  
ALDER JF, 1973, SPECTROCHIM ACTA B, V23, P421
[2]   SIGNAL ENHANCEMENT OF ELEMENTS DUE TO THE PRESENCE OF CARBON-CONTAINING COMPOUNDS IN INDUCTIVELY COUPLED PLASMA MASS-SPECTROMETRY [J].
ALLAIN, P ;
JAUNAULT, L ;
MAURAS, Y ;
MERMET, JM ;
DELAPORTE, T .
ANALYTICAL CHEMISTRY, 1991, 63 (14) :1497-1498
[3]   The use of Pt guard electrode in inductively coupled plasma sector field mass spectrometry: advantages and limitations [J].
Appelblad, PK ;
Rodushkin, I ;
Baxter, DC .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2000, 15 (04) :359-364
[4]   Multi-elemental characterization of soft biological tissues by inductively coupled plasma-sector field mass spectrometry [J].
Engström, E ;
Stenberg, A ;
Senioukh, S ;
Edelbro, R ;
Baxter, DC ;
Rodushkin, I .
ANALYTICA CHIMICA ACTA, 2004, 521 (02) :123-135
[5]   Determination of selenium in urine by inductively coupled plasma mass spectrometry: interferences and optimization [J].
Gammelgaard, B ;
Jons, O .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 1999, 14 (05) :867-874
[6]   ELIMINATION OF INTERFERENCES IN THE DETERMINATION OF ARSENIC AND SELENIUM IN BIOLOGICAL SAMPLES BY INDUCTIVELY-COUPLED PLASMA-MASS SPECTROMETRY [J].
GOOSSENS, J ;
VANHAECKE, F ;
MOENS, L ;
DAMS, R .
ANALYTICA CHIMICA ACTA, 1993, 280 (01) :137-143
[7]  
HUBER KP, 1979, MOL SPECTRA MOL STR, V4
[8]   Analytical procedures for improved trace element detection limits in polar ice from Arctic Canada using ICP-SMS [J].
Krachler, M ;
Zheng, J ;
Fisher, D ;
Shotyk, W .
ANALYTICA CHIMICA ACTA, 2005, 530 (02) :291-298
[9]   Novel calibration procedure for improving trace element determinations in ice and water samples using ICP-SMS [J].
Krachler, M ;
Zheng, J ;
Fisher, D ;
Shotyk, W .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2004, 19 (08) :1017-1019
[10]  
Krushevska A, 1996, FRESEN J ANAL CHEM, V355, P793