Application of conducting polymers in chemical analysis

被引:115
作者
Trojanowicz, M
机构
[1] Univ Warsaw, Dept Chem, PL-02093 Warsaw, Poland
[2] Inst Nucl Chem & Technol, PL-03195 Warsaw, Poland
关键词
conducting polymers; sensors; biosensors; solid-phase microextraction; HPLC;
D O I
10.1007/s00604-003-0066-5
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
This paper presents recent achievements in the field of analytical application of conducting polymers, most of which were published in the last five years. Based on 171 references mainly to original papers in international scientific journals, the applications of conducting polymers in the design of electrochemical and optical sensors, enzymatic biosensors and immunosensors are reviewed together with applications in analytical preconcentration procedures and high-performance separation techniques.
引用
收藏
页码:75 / 91
页数:17
相关论文
共 180 条
[81]  
2-#
[82]  
Krawczyk TKV, 1996, BIOSENS BIOELECTRON, V11, P1155, DOI 10.1016/0956-5663(96)82338-4
[83]   Preparation of potentiometric acetylcholine sensor using electropolymerized insulating poly-1-aminopyrrole with polyion complex [J].
Kuwahara, T ;
Yamakawa, N ;
Momma, T ;
Osaka, T .
ELECTROCHEMISTRY, 2001, 69 (08) :598-602
[84]   Bioelectrochemical application of some PQQ-dependent enzymes [J].
Laurinavicius, V ;
Razumiene, J ;
Kurtinaitiene, B ;
Lapenaite, I ;
Bachmatova, I ;
Marcinkeviciene, L ;
Meskys, R ;
Ramanavicius, A .
BIOELECTROCHEMISTRY, 2002, 55 (1-2) :29-32
[85]  
Letheby H., 1862, Journal of the Chemical Society, V15, P161, DOI [DOI 10.1039/JS8621500161, 10.1039/JS8621500161]
[86]  
LEWENSTAM A, Patent No. 5498323
[87]   Electrochemically controlled solid-phase microextraction and preconcentration using polypyrrole coated microarray electrodes in a flow system [J].
Liljegren, G ;
Nyholm, L .
ANALYST, 2003, 128 (03) :232-236
[88]   Electrochemical solid-phase microextraction of anions and cations using polypyrrole coatings and an integrated three-electrode device [J].
Liljegren, G ;
Pettersson, J ;
Markides, KE ;
Nyholm, L .
ANALYST, 2002, 127 (05) :591-597
[89]   All-solid-state calcium-selective electrode prepared of soluble electrically conducting polyaniline and di(2-ethylhexyl)phosphate with tetraoctylammonium chloride as cationic additive [J].
Lindfors, T ;
Ivaska, A .
ANALYTICA CHIMICA ACTA, 2000, 404 (01) :111-119
[90]   pH sensitivity of polyaniline and its substituted derivatives [J].
Lindfors, T ;
Ivaska, A .
JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 2002, 531 (01) :43-52