Application of conducting polymers in chemical analysis

被引:115
作者
Trojanowicz, M
机构
[1] Univ Warsaw, Dept Chem, PL-02093 Warsaw, Poland
[2] Inst Nucl Chem & Technol, PL-03195 Warsaw, Poland
关键词
conducting polymers; sensors; biosensors; solid-phase microextraction; HPLC;
D O I
10.1007/s00604-003-0066-5
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
This paper presents recent achievements in the field of analytical application of conducting polymers, most of which were published in the last five years. Based on 171 references mainly to original papers in international scientific journals, the applications of conducting polymers in the design of electrochemical and optical sensors, enzymatic biosensors and immunosensors are reviewed together with applications in analytical preconcentration procedures and high-performance separation techniques.
引用
收藏
页码:75 / 91
页数:17
相关论文
共 180 条
[31]   The determination of the surface energy of conducting polymers by inverse gas chromatography at infinite dilution [J].
Chehimi, MM ;
Abel, ML ;
Perruchot, C ;
Delamar, M ;
Lascelles, SF ;
Armes, SP .
SYNTHETIC METALS, 1999, 104 (01) :51-59
[32]   MODIFICATION OF ELECTRODE SURFACES WITH OXIDIZED PHENOLS TO CONFER SELECTIVITY TO AMPEROMETRIC BIOSENSORS FOR GLUCOSE DETERMINATION [J].
CHRISTIE, IM ;
VADGAMA, P ;
LLOYD, S .
ANALYTICA CHIMICA ACTA, 1993, 274 (02) :191-199
[33]   Redox chromatography using polypyrrole as a stationary phase [J].
Chriswanto, H ;
Wallace, GG .
JOURNAL OF LIQUID CHROMATOGRAPHY & RELATED TECHNOLOGIES, 1996, 19 (15) :2457-2476
[34]   Characterization of polyaniline using chromatographic studies [J].
Chriswanto, H ;
Wallace, GG .
CHROMATOGRAPHIA, 1996, 42 (3-4) :191-198
[35]   Biomolecule immobilization on electrode surfaces by entrapment or attachment to electrochemically polymerized films. A review [J].
Cosnier, S .
BIOSENSORS & BIOELECTRONICS, 1999, 14 (05) :443-456
[36]   In vivo studies of polypyrrole/peptide coated neural probes [J].
Cui, XY ;
Wiler, J ;
Dzaman, M ;
Altschuler, RA ;
Martin, DC .
BIOMATERIALS, 2003, 24 (05) :777-787
[37]   A new interference-free lysine biosensor using a non-conducting polymer film [J].
Curulli, A ;
Kelly, S ;
O'Sullivan, C ;
Guilbault, GG ;
Palleschi, G .
BIOSENSORS & BIOELECTRONICS, 1998, 13 (12) :1245-1250
[38]   The use of polymers coupled with metallised electrodes to allow H2O2 detection in the presence of electrochemical interferences [J].
Daly, DJ ;
O'Sullivan, CK ;
Guilbault, GG .
TALANTA, 1999, 49 (03) :667-678
[39]   Optical sensing of pH based on polypyrrole films [J].
deMarcos, S ;
Wolfbeis, OS .
ANALYTICA CHIMICA ACTA, 1996, 334 (1-2) :149-153
[40]   AN ELECTROCHEMICALLY GROWN POLYMER AS AN IMMOBILIZATION MATRIX FOR WHOLE CELLS - APPLICATION IN AN AMPEROMETRIC DOPAMINE SENSOR [J].
DESHPANDE, MV ;
HALL, EAH .
BIOSENSORS & BIOELECTRONICS, 1990, 5 (06) :431-448