The effect of activity levels of total hip arthroplasty patients on socket penetration

被引:25
作者
Goldsmith, AAJ [1 ]
Dowson, D [1 ]
Wroblewski, BM [1 ]
Siney, PD [1 ]
Fleming, PA [1 ]
Lane, JM [1 ]
机构
[1] Univ Leeds, Sch Mech Engn, Leeds, W Yorkshire, England
关键词
activity; total hip arthroplasty; wear;
D O I
10.1054/arth.2001.23566
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Survivorship of total hip arthroplasties (THAs) has been linked to penetration of the femoral head into the polyethylene acetabular cup and to polyethylene wear. The activity level of patients with THAs is considered to be all important factor affecting wear, and the purpose of this study was to explore the relationship between activity as recorded by pedometers and cup penetration. The measurement of daily activity levels of normal subjects and THA patients of various ages are discussed in another article [1]. Subjects were monitored continuously during 2- to 4-week periods using simple pedometer devices. Patients (n = 54; mean age, 58 years) from the Centre for Hip Surgery at Wrightington Hospital for whom (lie penetration data also were available were included in the study. The average activity level for the patient group was 1.426 million loading cycles on each hip joint per year. Radiographic penetration measurements were compared for 81 hips in 54 patients with a mean follow-up of 13.1 years (range, 1.3-26.4 years). The overall correlation of penetration with implantation period is known to be poor, however, and did not improve significantly when the penetration was plotted against a new parameter that took account of not only implant life, but also the level of activity and patient weight. The considerable scatter of penetration levels was noted to increase with increasing implantation period, which indicates that in the multifactorial problem of polyethylene wear, other factors, particularly femoral head surface finish or polyethylene deterioration, may predominate.
引用
收藏
页码:620 / 627
页数:8
相关论文
共 41 条
[1]
LABORATORY WEAR TESTS AND CLINICAL OBSERVATIONS OF THE PENETRATION OF FEMORAL HEADS INTO ACETABULAR CUPS IN TOTAL REPLACEMENT HIP JOINTS .2. A MICROSCOPICAL STUDY OF THE SURFACES OF CHARNLEY POLYETHYLENE ACETABULAR SOCKETS [J].
ATKINSON, JR ;
DOWSON, D ;
ISAAC, GH ;
WROBLEWSI, BM .
WEAR, 1985, 104 (03) :217-224
[2]
Wear of ultra-high molecular weight polyethylene acetabular cups in a physiological hip joint simulator in the anatomical position using bovine serum as a lubricant [J].
Bigsby, RJA ;
Hardaker, CS ;
Fisher, J .
PROCEEDINGS OF THE INSTITUTION OF MECHANICAL ENGINEERS PART H-JOURNAL OF ENGINEERING IN MEDICINE, 1997, 211 (03) :265-269
[3]
Chan FW, 1996, CLIN ORTHOP RELAT R, P96
[4]
16- to 25-year follow-up study of cemented arthroplasty of the hip in patients aged 50 years or younger [J].
Devitt, A ;
OSullivan, T ;
Quinlan, W .
JOURNAL OF ARTHROPLASTY, 1997, 12 (05) :479-489
[5]
THE ROLE OF COUNTERFACE IMPERFECTIONS IN THE WEAR OF POLYETHYLENE [J].
DOWSON, D ;
TAHERI, S ;
WALLBRIDGE, NC .
WEAR, 1987, 119 (03) :277-293
[6]
Dowson D, 1988, Eng Med, V17, P111, DOI 10.1243/EMED_JOUR_1988_017_031_02
[7]
Feller J A, 1994, J Arthroplasty, V9, P341, DOI 10.1016/0883-5403(94)90042-6
[8]
Fisher J, 1995, Proc Inst Mech Eng H, V209, P263, DOI 10.1243/PIME_PROC_1995_209_353_02
[9]
Fisher J., 1994, CURR ORTHOPAED, V8, P164, DOI DOI 10.1016/0268-0890(94)90048-5
[10]
A multi-station hip joint simulator study of the performance of 22 mm diameter zirconia-ultra-high molecular weight polyethylene total replacement hip joints [J].
Goldsmith, AAJ ;
Dowson, D .
PROCEEDINGS OF THE INSTITUTION OF MECHANICAL ENGINEERS PART H-JOURNAL OF ENGINEERING IN MEDICINE, 1999, 213 (H2) :77-90