The effect of activity levels of total hip arthroplasty patients on socket penetration

被引:25
作者
Goldsmith, AAJ [1 ]
Dowson, D [1 ]
Wroblewski, BM [1 ]
Siney, PD [1 ]
Fleming, PA [1 ]
Lane, JM [1 ]
机构
[1] Univ Leeds, Sch Mech Engn, Leeds, W Yorkshire, England
关键词
activity; total hip arthroplasty; wear;
D O I
10.1054/arth.2001.23566
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Survivorship of total hip arthroplasties (THAs) has been linked to penetration of the femoral head into the polyethylene acetabular cup and to polyethylene wear. The activity level of patients with THAs is considered to be all important factor affecting wear, and the purpose of this study was to explore the relationship between activity as recorded by pedometers and cup penetration. The measurement of daily activity levels of normal subjects and THA patients of various ages are discussed in another article [1]. Subjects were monitored continuously during 2- to 4-week periods using simple pedometer devices. Patients (n = 54; mean age, 58 years) from the Centre for Hip Surgery at Wrightington Hospital for whom (lie penetration data also were available were included in the study. The average activity level for the patient group was 1.426 million loading cycles on each hip joint per year. Radiographic penetration measurements were compared for 81 hips in 54 patients with a mean follow-up of 13.1 years (range, 1.3-26.4 years). The overall correlation of penetration with implantation period is known to be poor, however, and did not improve significantly when the penetration was plotted against a new parameter that took account of not only implant life, but also the level of activity and patient weight. The considerable scatter of penetration levels was noted to increase with increasing implantation period, which indicates that in the multifactorial problem of polyethylene wear, other factors, particularly femoral head surface finish or polyethylene deterioration, may predominate.
引用
收藏
页码:620 / 627
页数:8
相关论文
共 41 条
[21]
Number of polyethylene particles and osteolysis in total joint replacements - A quantitative study using a tissue-digestion method [J].
Kobayashi, A ;
Freeman, MAR ;
Bonfield, W ;
Kadoya, Y ;
Yamac, T ;
AlSaffar, N ;
Scott, G ;
Revell, PA .
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 1997, 79B (05) :844-848
[22]
Factors affecting aseptic failure of fixation after primary charnley total hip arthroplasty - Multivariate survival analysis [J].
Kobayashi, S ;
Takaoka, K ;
Saito, N ;
Hisa, K .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1997, 79A (11) :1618-1627
[23]
KOBOYASHI S, 1997, CLIN ORTHOPAEDICS, V339, P140
[24]
Femoral component wear in retrieved hip prostheses [J].
Kusaba, A ;
Kuroki, Y .
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 1997, 79B (02) :331-336
[25]
MCKELLOP HA, 1995, CLIN ORTHOP RELAT R, P3
[26]
THE WEAR BEHAVIOR OF ION-IMPLANTED TI-6AL-4V AGAINST UHMW POLYETHYLENE [J].
MCKELLOP, HA ;
ROSTLUND, TV .
JOURNAL OF BIOMEDICAL MATERIALS RESEARCH, 1990, 24 (11) :1413-1425
[27]
Quantification of third-body damage and its effect on UHMWPE wear with different types of femoral head [J].
Minakawa, H ;
Stone, MH ;
Wroblewski, BM ;
Lancaster, JG ;
Ingham, E ;
Fisher, J .
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 1998, 80B (05) :894-899
[28]
WEAR OF POLYETHYLENE ACETABULAR CUPS AGAINST ZIRCONIA FEMORAL HEADS STUDIED WITH A HIP-JOINT SIMULATOR [J].
SAIKKO, V .
WEAR, 1994, 176 (02) :207-212
[29]
THE RELATIONSHIP BETWEEN THE DESIGN, POSITION, AND ARTICULAR WEAR OF ACETABULAR COMPONENTS INSERTED WITHOUT CEMENT AND THE DEVELOPMENT OF PELVIC OSTEOLYSIS [J].
SCHMALZRIED, TP ;
GUTTMANN, D ;
GRECULA, M ;
AMSTUTZ, HC .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1994, 76A (05) :677-688
[30]
PERIPROSTHETIC BONE LOSS IN TOTAL HIP-ARTHROPLASTY - POLYETHYLENE WEAR DEBRIS AND THE CONCEPT OF THE EFFECTIVE JOINT SPACE [J].
SCHMALZRIED, TP ;
JASTY, M ;
HARRIS, WH .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1992, 74A (06) :849-863