Multislice computed tomography for preoperative and postoperative assessment in totally endoscopic coronary artery bypass grafting

被引:5
作者
Feuchtner, Gudrun
Schachner, Thomas
Junker, Daniel
Bonaros, Nikolaos
Oehlinger, Armin
Friedrich, Guy
Cooper, Joseph
Laufer, Guenther
Bonatti, Johannes
机构
[1] Innsbruck Med Univ, Clin Dept Radiol 2, A-6020 Innsbruck, Austria
[2] Innsbruck Med Univ, Clin Dept Cardiac Surg, A-6020 Innsbruck, Austria
[3] Innsbruck Med Univ, Clin Dept Cardiol, A-6020 Innsbruck, Austria
关键词
D O I
10.1532/HSF98.20070705
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
This article reviews the clinical value of noninvasive multislice computed tomography (MSCT) angiography before and after totally endoscopic coronary artery bypass surgery. The use of coronary and aorto-iliaco-femoral MSCT angiography in the preoperative assessment is addressed and the use of bypass MSCT angiography for postoperative control of bypass graft patency is discussed.
引用
收藏
页码:E243 / E247
页数:5
相关论文
共 26 条
[1]   Results of the prospective multicenter trial of robotically assisted totally endoscopic coronary artery bypass grafting [J].
Argenziano, M ;
Katz, M ;
Bonatti, J ;
Srivastava, S ;
Murphy, D ;
Poirier, R ;
Loulmet, D ;
Siwek, L ;
Kreaden, U ;
Ligon, D .
ANNALS OF THORACIC SURGERY, 2006, 81 (05) :1666-1675
[2]   Technical challenges in totally endoscopic robotic coronary artery bypass grafting [J].
Bonatti, J ;
Schachner, T ;
Bonaros, N ;
Öhlinger, A ;
Danzmayr, M ;
Jonetzko, P ;
Friedrich, G ;
Kolbitsch, C ;
Mair, P ;
Laufer, G .
JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 2006, 131 (01) :146-153
[3]   Infrarenal aortic and lower-extremity arterial disease: Diagnostic performance of multi-detector row CT angiography [J].
Catalano, C ;
Fraioli, F ;
Laghi, A ;
Napoli, A ;
Bezzi, M ;
Pediconi, F ;
Danti, M ;
Nofroni, I ;
Passariello, R .
RADIOLOGY, 2004, 231 (02) :555-563
[4]   Follow-up of coronary artery bypass graft patency by multislice computed tomography [J].
Chiurlia, E ;
Menozzi, M ;
Ratti, C ;
Romagnoli, R ;
Modena, MG .
AMERICAN JOURNAL OF CARDIOLOGY, 2005, 95 (09) :1094-1097
[5]   Multislice computed tomography for detection of patients with aortic valve stenosis and quantification of severity [J].
Feuchtner, GM ;
Dichtl, W ;
Friedrich, GJ ;
Frick, M ;
Alber, H ;
Schachner, T ;
Bonatti, J ;
Matlouhi, A ;
Frede, T ;
Pachinger, O ;
Nedden, DZ ;
Müller, S .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2006, 47 (07) :1410-1417
[6]  
FEUCHTNER GM, 2006, EUR RADIOL, V16, pB170
[7]   Diagnostic performance of MDCT for detecting aortic valve regurgitation [J].
Feuchtner, Gudrun M. ;
Dichtl, Wolfgang ;
Schachner, Thomas ;
Mueller, Silvana ;
Mallouhi, Ammar ;
Friedrich, Guy J. ;
Nedden, Dieter zur .
AMERICAN JOURNAL OF ROENTGENOLOGY, 2006, 186 (06) :1676-1681
[8]   Evaluation of ascending aortic atherosclerosis with 16-multidetector computed tomography is useful before total endoscopic coronary bypass surgery [J].
Feuchtner, Gudrun Maria ;
Schachner, Thomas ;
Bonaros, Nikolaos ;
Smekal, Alexander ;
Mallouhi, Ammar ;
Friedrich, Guy J. ;
Deutschmann, Martin ;
Laufer, Guenther ;
zur Nedden, Dieter ;
Bonatti, Johannes .
HEART SURGERY FORUM, 2006, 9 (05) :E754-E758
[9]   Improved uniformity of aortic enhancement with customized contrast medium injection protocols at CT angiography [J].
Fleischmann, D ;
Rubin, GD ;
Bankier, AA ;
Hittmair, K .
RADIOLOGY, 2000, 214 (02) :363-371
[10]   Performance evaluation of a 64-slice CT system with z-flying focal spot [J].
Flohr, T ;
Stierstorfer, K ;
Raupach, R ;
Ulzheimer, S ;
Bruder, H .
ROFO-FORTSCHRITTE AUF DEM GEBIET DER RONTGENSTRAHLEN UND DER BILDGEBENDEN VERFAHREN, 2004, 176 (12) :1803-1810