Experimental determination of the energy efficiency of an air-cooled chiller under part load conditions

被引:49
作者
Yu, FW [1 ]
Chan, KT [1 ]
机构
[1] Hong Kong Polytech Univ, Dept Bldg Serv Engn, Kowloon 852, Hong Kong, Peoples R China
关键词
D O I
10.1016/j.energy.2004.11.007
中图分类号
O414.1 [热力学];
学科分类号
摘要
In cities located in a subtropical climate, air-cooled chillers are commonly used to provide cooling to the indoor environment. This accounts for the increasing electricity demand of buildings over the decades. This paper investigates how the condensing temperature serves to accurately determine the energy efficiency, or coefficient of performance (COP), of air-cooled chillers under part load conditions. An experiment on an air-cooled reciprocating chiller showed that for any given operating condition, the COP of the chiller varies, depending on how the condensing temperature is controlled. A sensitivity analysis is implemented to investigate to what extent COP is responding to changes in operating variables and confirms that the condensing temperature is an adequate variable to gauge COP under various operating conditions. The specifications of the upper limit for the condensing temperature in order to improve the energy efficiency of air-cooled chillers are discussed. The results of this work will give designers and researchers a good idea about how to model chiller energy performance curves in the thermal and energy computation exercises. (c) 2004 Elsevier Ltd. All rights reserved.
引用
收藏
页码:1747 / 1758
页数:12
相关论文
共 17 条
[1]  
*AIR COND REFR I, 1998, 550590 AIR COND REFR
[2]  
AUSTIN SB, 1991, ASHRAE J, V33, P40
[3]  
Chan K.T., 2002, BUILD SERV ENG RES T, V23, P29
[4]   Optimum setpoint of condensing temperature for air-cooled chillers [J].
Chan, KT ;
Yu, FW .
HVAC&R RESEARCH, 2004, 10 (02) :113-127
[5]   Applying condensing-temperature control in air-cooled reciprocating water chillers for energy efficiency [J].
Chan, KT ;
Yu, FW .
APPLIED ENERGY, 2002, 72 (3-4) :565-581
[6]  
CHAN KT, 2003, ENERGY ENV, V2, P1419
[7]   Electricity use characteristics of purpose-built office buildings in subtropical climates [J].
Lam, JC ;
Chan, RYC ;
Tsang, CL ;
Li, DHW .
ENERGY CONVERSION AND MANAGEMENT, 2004, 45 (06) :829-844
[8]   Energy analysis of commercial buildings in subtropical climates [J].
Lam, JC .
BUILDING AND ENVIRONMENT, 2000, 35 (01) :19-26
[9]   A strategy for prioritising interactive measures for enhancing energy efficiency of air-conditioned buildings [J].
Lee, WL ;
Yik, FWH ;
Jones, P .
ENERGY, 2003, 28 (08) :877-893
[10]   Energy saving by realistic design data for commercial buildings in Hong Kong [J].
Lee, WL ;
Yik, FWH ;
Jones, P ;
Burnett, J .
APPLIED ENERGY, 2001, 70 (01) :59-75