Clinical experience with an automatic threshold tracking algorithm study

被引:7
作者
Kennergren, C
Larsson, B
Uhrenius, Å
Gadler, F [1 ]
机构
[1] Karolinska Sjukhuset, Kardiol Kliniken, Dept Cardiol, SE-17176 Stockholm, Sweden
[2] Sahlgrens Univ Hosp, Dept Cardiothorac Surg, S-41345 Gothenburg, Sweden
[3] St Jude Med AB, Jarfalla, Sweden
来源
PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY | 2003年 / 26卷 / 12期
关键词
AutoCapture; unipolar pacing; evoked response signal; lead polarization;
D O I
10.1111/j.1540-8159.2003.00350.x
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
The automatic threshold tracking pacing system algorithm developed by St. Jude Medical, verifies ventricular capture beat by beat by recognizing the evoked response (ER)following each pacemaker stimulus. The present automatic threshold tracking function requires a bipolar ventricular lead with low polarization. The aim of this study was to evaluate a new algorithm developed to use with unipolar leads with different levels of polarization. An external pacemaker with the ability to sense intrinsic R waves and measure ER signals, as well as deliver stimulus, was used. An algorithm for detecting the true ER in a unipolar sensing configuration (tip-case) was developed. Based on the assumption that the true evoked R wave amplitude is independent of the stimulation amplitude, the algorithm calculates and subtracts the polarization present at any pacing stimulus from the measured ER. The resulting signal is analyzed to verify capture. This study comprises 35 patients of which 26 were new implants and 9 had chronic leads. The automatic thresh old-tracking algorithm was calibrated for each patient and pacing was performed at different pulse amplitudes and pulse duration. Capture was verified for each paced beat. The recordings were stored for later comparison with the tape-recorded intracardiac heart signals. The new algorithm correctly verified capture or loss of capture for every single analyzed beat at the different pacing outputs in every individual patient. The results from this initial study suggests that the new ER detection principle will allow automatic threshold tracking to be used not only with low polarization bipolar leads but with most leads.
引用
收藏
页码:2219 / 2224
页数:6
相关论文
共 7 条
[1]  
BAIG MW, 1992, BRIT HEART J, V68, P398
[2]   Automatic adjustment of pacemaker stimulation output correlated with continuously monitored capture thresholds:: A multicenter study [J].
Clarke, M ;
Liu, B ;
Schüller, H ;
Binner, L ;
Kennergren, C ;
Guerola, M ;
Weinmann, P ;
Ohm, OJ .
PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 1998, 21 (08) :1567-1575
[3]   Intraoperative study of polarization and evoked response signals in different endocardial electrode designs [J].
Lau, C ;
Nishimura, SC ;
Yee, R ;
Lefeuvre, C ;
Philippon, F ;
Cameron, DA .
PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 2001, 24 (07) :1055-1060
[4]  
MUGICA J, 1973, CARDIAC PACING, P150
[5]  
PRESTON TA, 1973, CARDIAC PACING, P295
[6]   Improved differentiation of the ventricular evoked response from polarization by modification of the pacemaker impulse [J].
Provenier, F ;
Germonpré, E ;
De Wagter, X .
PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 2000, 23 (12) :2073-2077
[7]   Adjustment of the evoked response sensitivity after hospital discharge in pacemaker patients with automatic ventricular threshold tracking activated [J].
Schuchert, A ;
Ventura, R ;
Meinertz, T .
PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 2001, 24 (02) :212-216