Optimization and robustness of blood tests for liver fibrosis and cirrhosis

被引:34
作者
Cales, Paul [1 ,2 ]
Boursier, Jerome [1 ,2 ]
Bertrais, Sandrine [2 ]
Oberti, Frederic [1 ,2 ]
Gallois, Yves [2 ,3 ]
Fouchard-Hubert, Isabelle [1 ,2 ]
Dib, Nina [1 ,2 ]
Zarski, Jean-Pierre [5 ,6 ]
Rousselet, Marie Christine [2 ,4 ]
机构
[1] CHU Angers, Serv Hepatogastroenterol, F-49933 Angers 09, France
[2] Univ Angers, IFR 132, UPRES 3859, Lab HIFIH, Angers, Pres Unam, France
[3] CHU Angers, Dept Pathol Cellulaire & Tissulaire, Angers, France
[4] CHU Angers, Lab Biochim & Biol Mol, Angers, France
[5] CHU Grenoble, Pole Digestif DUNE, Clin Hepatogastroenterol, F-38043 Grenoble, France
[6] IAB, IAPC, INSERM UJF U823, Grenoble, France
关键词
Liver fibrosis; Liver biopsy; Diagnostic accuracy; Blood test; Fibroscan; Hepatitis C; Diagnosis; Bootstrap; CHRONIC HEPATITIS-C; DIAGNOSTIC-ACCURACY; SERUM MARKERS; VIRUS-INFECTION; REPRODUCIBILITY; PERFORMANCE; ELASTOGRAPHY; METAANALYSIS; PROGRESSION; BIOMARKERS;
D O I
10.1016/j.clinbiochem.2010.08.010
中图分类号
R446 [实验室诊断]; R-33 [实验医学、医学实验];
学科分类号
1001 ;
摘要
Objectives: To optimize the performance and feasibility of fibrosis blood tests and evaluate their robustness. Design and methods: The derivation population included 1056 HCV patients with liver biopsy and blood markers. Validation populations included 984 patients with various viral hepatitis causes, and Fibroscan and/or liver biopsy and/or blood markers. Results: The bootstrap method validated the markers of the original FibroMeter(2G), but not those of Fibrotest and Hepascore, and provided a hyaluronate-free FibroMeter(3G). AUROCs for significant fibrosis were: FibroMeter(2G): 0.853 vs. FibroMeter(3G): 0.851, p = 0.489. Compared to FibroMeter(2G), FibroMeter(3G) had a significantly higher patient rate with predictive values >= 90% for significant fibrosis. Accuracy for fibrosis stage classification was: Fibrotest: 37.9%, FibroMeter(2G): 74.9%, and FibroMeter(3G): 86.9% (p<10(-3)). Conclusion: The bootstrap method validated FibroMeter(2G) and provided a cheaper and more feasible hyaluronate-free FibroMeter(3G) with comparable performance. Compared to binary diagnosis, fibrosis stage classification increased discrimination, with an increased accuracy to 87% for FibroMeter(3G). (C) 2010 The Canadian Society of Clinical Chemists. Published by Elsevier Inc. All rights reserved.
引用
收藏
页码:1315 / 1322
页数:8
相关论文
共 34 条
[1]   Hepascore: An accurate validated predictor of liver fibrosis in chronic hepatitis C infection [J].
Adams, LA ;
Bulsara, M ;
Rossi, E ;
Deboer, B ;
Speers, D ;
George, J ;
Kench, J ;
Farrell, G ;
McCaughan, GW ;
Jeffrey, GP .
CLINICAL CHEMISTRY, 2005, 51 (10) :1867-1873
[2]  
ARMITAGE P, 1994, INTRACLASS CORRELATI, P273
[3]   Using the bootstrap to improve estimation and confidence intervals for regression coefficients selected using backwards variable elimination [J].
Austin, Peter C. .
STATISTICS IN MEDICINE, 2008, 27 (17) :3286-3300
[4]  
BEDOSSA P, 1994, HEPATOLOGY, V20, P15
[5]   Comparison of Elastography, Serum Marker Scores, and Histology for the Assessment of Liver Fibrosis in Hepatitis B Virus (HBV)-Infected Patients in Burkina Faso [J].
Bonnard, Philippe ;
Sombie, Roger ;
Lescure, Francois-Xavier ;
Bougouma, Alain ;
Guiard-Schmid, Jean Baptiste ;
Poynard, Thierry ;
Cales, Paul ;
Housset, Chantal ;
Callard, Patrice ;
Le Pendeven, Catherine ;
Drabo, Joseph ;
Carrat, Fabrice ;
Pialoux, Gilles .
AMERICAN JOURNAL OF TROPICAL MEDICINE AND HYGIENE, 2010, 82 (03) :454-458
[6]   The STARD statement for reporting studies of diagnostic accuracy: Explanation and elaboration [J].
Bossuyt, PM ;
Reitsma, JB ;
Bruns, DE ;
Gatsonis, CA ;
Glasziou, PP ;
Irwig, LM ;
Moher, D ;
Rennie, D ;
de Vet, HCW ;
Lijmer, JG .
CLINICAL CHEMISTRY, 2003, 49 (01) :7-18
[7]   Performance of 11 biomarkers for liver fibrosis assessment in HIV/HBV co-infected patients [J].
Bottero, Julie ;
Lacombe, Karine ;
Guechot, Jerome ;
Serfaty, Lawrence ;
Miailhes, Patrick ;
Bonnard, Philippe ;
Wendum, Dominique ;
Molina, Jean-Michel ;
Lascoux-Combe, Caroline ;
Girard, Pierre-Marie .
JOURNAL OF HEPATOLOGY, 2009, 50 (06) :1074-1083
[8]   Reproducibility of Liver Stiffness Measurement by Ultrasonographic Elastometry [J].
Boursier, Jerome ;
Konate, Anselme ;
Gorea, Gabriella ;
Reaud, Stephanie ;
Quemener, Emmanuel ;
Oberti, Frederic ;
Hubert-Fouchard, Isabelle ;
Dib, Nina ;
Cales, Paul .
CLINICAL GASTROENTEROLOGY AND HEPATOLOGY, 2008, 6 (11) :1263-1269
[9]   Improved diagnostic accuracy of blood tests for severe fibrosis and cirrhosis in chronic hepatitis C [J].
Boursier, Jerome ;
Bacq, Yannick ;
Halfon, Philippe ;
Leroy, Vincent ;
de Ledinghen, Victor ;
de Muret, Anne ;
Bourliere, Marc ;
Sturm, Nathalie ;
Foucher, Juliette ;
Oberti, Frederic ;
Rousselet, Marie Christine ;
Cales, Paul .
EUROPEAN JOURNAL OF GASTROENTEROLOGY & HEPATOLOGY, 2009, 21 (01) :28-38
[10]   Comparison of non-invasive liver fibrosis biomarkers in HIV/HCV co-infected patients:: The fibrovic study -: ANRS HC02 [J].
Cacoub, Patrice ;
Carrat, Fabrice ;
Bedossa, Pierre ;
Lambert, Jerome ;
Penaranda, Guillaume ;
Perronne, Christian ;
Pol, Stanislas ;
Halfon, Philippe .
JOURNAL OF HEPATOLOGY, 2008, 48 (05) :765-773