Coronary MR angiography during peak-systole: Work in progress

被引:21
作者
Duerinckx, A [1 ]
Atkinson, DP [1 ]
机构
[1] W Los Angeles Vet Affairs Med Ctr, Serv Radiol, MRI, Los Angeles, CA 90073 USA
关键词
cardiac MRI; heart; coronary vessels; MRI; coronary angiography; systole; diastole; image quality;
D O I
10.1002/jmri.1880070608
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
The purpose of this study is to compare the quality of images of coronary arteries obtained with two-dimensional breath-hold coronary MR angiography during peak systole and mid diastole, Two-dimensional coronary MR angiography was performed in eight normal volunteers at peak systole and in mid diastole with a commercial 1.5-T MR imager, An ultrafast gradient-echo sequence with incremented flip angle series and k-space segmentation was used. The image quality grade, length, and proximal diameter of each visualized coronary artery were measured. The highest quality images in systole and diastole were compared. Coronary MR angiography provided high quality images in systole and diastole in 14 of 16 coronary vessels (87.5%), In 8 of 14 vessels (57%), there was no visible coronary MR angiogram image degradation when comparing peak systolic with mid-diastolic images. In 4 of 14 vessels (29%), there was mild MR image degradation. There was significant MR image degradation in only one case (7%). And in one case (7%), there was mild image improvement during systole. The width and length of the visualized coronary vessels did not change significantly from diastole to systole, Existing two-dimensional breath-hold coronary MR angiography provides MR images during peak systole and mid-diastole with little or no perceptible difference in quality.
引用
收藏
页码:979 / 986
页数:8
相关论文
共 49 条
[1]   ESTIMATION OF TOTAL CORONARY-ARTERY FLOW USING MEASUREMENTS OF FLOW IN THE ASCENDING AORTA [J].
BUONOCORE, MH .
MAGNETIC RESONANCE IN MEDICINE, 1994, 32 (05) :602-611
[2]   FACTORS INFLUENCING THE ACCURACY AND PRECISION OF VELOCITY-ENCODED PHASE IMAGING [J].
BUONOCORE, MH ;
BOGREN, H .
MAGNETIC RESONANCE IN MEDICINE, 1992, 26 (01) :141-154
[3]  
BUSER PT, 1994, CORONARY ARTERY GRAF, P99
[4]   MEASUREMENT OF ABSOLUTE EPICARDIAL CORONARY-ARTERY FLOW AND FLOW RESERVE WITH BREATH-HOLD CINE PHASE-CONTRAST MAGNETIC-RESONANCE-IMAGING [J].
CLARKE, GD ;
ECKELS, R ;
CHANEY, C ;
SMITH, D ;
DITTRICH, J ;
HUNDLEY, WG ;
NESSAIVER, M ;
LI, HF ;
PARKEY, RW ;
PESHOCK, RM .
CIRCULATION, 1995, 91 (10) :2627-2634
[5]   RENAL-ARTERY BLOOD-FLOW - QUANTITATION WITH PHASE-CONTRAST MR-IMAGING WITH AND WITHOUT BREATH-HOLDING [J].
DEBATIN, JF ;
TING, RH ;
WEGMULLER, H ;
SOMMER, FG ;
FREDRICKSON, JO ;
BROSNAN, TJ ;
BOWMAN, BS ;
MYERS, BD ;
HERFKENS, RJ ;
PELC, NJ .
RADIOLOGY, 1994, 190 (02) :371-378
[6]   LUMEN DIAMETER OF NORMAL HUMAN CORONARY-ARTERIES - INFLUENCE OF AGE, SEX, ANATOMIC VARIATION, AND LEFT-VENTRICULAR HYPERTROPHY OR DILATION [J].
DODGE, JT ;
BROWN, BG ;
BOLSON, EL ;
DODGE, HT .
CIRCULATION, 1992, 86 (01) :232-246
[7]  
Duerinckx A J, 1996, Magn Reson Imaging Clin N Am, V4, P361
[8]  
Duerinckx AJ, 1996, EUR RADIOL, V6, P312
[9]   CORONARY MR-ANGIOGRAPHY AFTER CORONARY STENT PLACEMENT [J].
DUERINCKX, AJ ;
ATKINSON, D ;
HURWITZ, R ;
MINTOROVITCH, J ;
WHITNEY, W .
AMERICAN JOURNAL OF ROENTGENOLOGY, 1995, 165 (03) :662-664
[10]   CORONARY MR-ANGIOGRAPHY - RESPONSE [J].
DUERINCKX, AJ .
RADIOLOGY, 1995, 195 (03) :876-876