ESTIMATION OF TOTAL CORONARY-ARTERY FLOW USING MEASUREMENTS OF FLOW IN THE ASCENDING AORTA

被引:7
作者
BUONOCORE, MH
机构
[1] Department of Radiology, UC Davis Medical Center, Sacramento, California
关键词
MAGNETIC RESONANCE IMAGING; FLOW MEASUREMENTS; CORONARY ARTERY FLOW; IMAGE PROCESSING;
D O I
10.1002/mrm.1910320509
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
This paper describes a technique for estimation of total (right+left) coronary artery flow using MRI flow measurements in the ascending aorta. The technique is based on the principle that the flow in a vessel branch is equal to the difference of the net flow measured above and below the branch ostia. Aortic net flow is measured at four or more axial oblique slices from below the aortic valve to above the highest location of the coronary vessel ostia in late diastole. A flow model properly interprets the flow measurements in slices that contain the coronary ostia. Results in five normal subjects show that total coronary artery flow can be measured with a standard error of about 90 cc/min, 30% of total coronary artery flow. Potential clinical uses include noninvasive measurement of coronary flow reserve. Pulse sequence improvements are necessary to reduce examination time and improve accuracy and precision.
引用
收藏
页码:602 / 611
页数:10
相关论文
共 16 条
  • [1] BLOOD-FLOW MEASUREMENTS IN THE AORTA AND MAJOR ARTERIES WITH MR VELOCITY MAPPING
    BOGREN, HG
    BUONOCORE, MH
    [J]. JOURNAL OF MAGNETIC RESONANCE IMAGING, 1994, 4 (02) : 119 - 130
  • [2] MEASUREMENT OF CORONARY-ARTERY FLOW RESERVE BY MAGNETIC-RESONANCE VELOCITY MAPPING IN THE AORTA
    BOGREN, HG
    BUONOCORE, MH
    [J]. LANCET, 1993, 342 (8876) : 899 - 900
  • [3] FACTORS INFLUENCING THE ACCURACY AND PRECISION OF VELOCITY-ENCODED PHASE IMAGING
    BUONOCORE, MH
    BOGREN, H
    [J]. MAGNETIC RESONANCE IN MEDICINE, 1992, 26 (01) : 141 - 154
  • [4] BLOOD-FLOW MEASUREMENT USING VARIABLE VELOCITY ENCODING IN THE RR INTERVAL
    BUONOCORE, MH
    [J]. MAGNETIC RESONANCE IN MEDICINE, 1993, 29 (06) : 790 - 795
  • [5] BUONOCORE MH, 1991, 10TH ANN M SOC MAGN, P804
  • [6] CLARKE GD, 1994, 1ST P SMRM ANN M, pS26
  • [7] DEBATIN JF, 1994, J MAGN RESON IMAGING, V4, P44
  • [8] FLOW VELOCITY QUANTIFICATION IN HUMAN CORONARY-ARTERIES WITH FAST, BREATH-HOLD MR-ANGIOGRAPHY
    EDELMAN, RR
    MANNING, WJ
    GERVINO, E
    LI, W
    [J]. JMRI-JOURNAL OF MAGNETIC RESONANCE IMAGING, 1993, 3 (05): : 699 - 703
  • [9] Grossman W, 1991, CARDIAC CATHETERIZAT
  • [10] KLIPSTEIN RH, 1987, BRIT HEART J, V58, P316