Electrochemiluminescence enzyme immunoassays for TNT and pentaerythritol tetranitrate

被引:71
作者
Wilson, R [1 ]
Clavering, C
Hutchinson, A
机构
[1] Univ Liverpool, Dept Chem, Liverpool L69 7ZD, Merseyside, England
[2] Def Sci & Technol Lab, Sevenoaks, Kent TN14 7BP, England
关键词
D O I
10.1021/ac034163s
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Electrochemiluminescence enzyme immunoassays for 2,4,6-trinitrotoluene (TNT) and pentaerythritol tetranitrate (PETN) are described. The latter is, to the best of our knowledge, the first report of an immunoassay for PETN. Haptens corresponding to these explosives were covalently attached to high-affinity dextran-coated paramagnetic beads. The beads were mixed with the corresponding Fab fragments and the sample. After adding a second HRP-labeled antispecies-specific antibody, the mixture was pumped into an electrochemiluminometer where beads we;concentrated on the working electrode magnetically. The; amount of analyte in the sample was determined by measuring light emission when H2O2 was generated electrochemically in the presence of luminol and an enhancer. The detection limits for TNT and PETN were 0.11 and 19.8 ppb, respectively. Details of bead preparation and performance are given. The increase in sensitivity obtained when Fab fragments are used instead of whole antibodies is explained, and the implications of this observation for nanoparticle-based assays are discussed.
引用
收藏
页码:4244 / 4249
页数:6
相关论文
共 39 条
[1]   An electrochemiluminescence flow through-cell and its applications to sensitive immunoassay using N-(aminobutyl)-N-ethylisoluminol [J].
Arai, K ;
Takahashi, K ;
Kusu, F .
ANALYTICAL CHEMISTRY, 1999, 71 (11) :2237-2240
[2]  
BLACKBURN GF, 1991, CLIN CHEM, V37, P1534
[3]   Synthesis of haptens and their protein conjugates for immunological determination of nitrate esters and nitramines [J].
Blackburn, GM ;
Beadham, IG ;
Adams, H ;
Hutchinson, AP ;
Nicklin, S .
JOURNAL OF THE CHEMICAL SOCIETY-PERKIN TRANSACTIONS 1, 2000, (02) :225-230
[4]   CHARACTERIZATION OF EXPLOSIVES BY LIQUID-CHROMATOGRAPHY MASS-SPECTROMETRY AND LIQUID-CHROMATOGRAPHY TANDEM MASS-SPECTROMETRY USING ELECTROSPRAY-IONIZATION AND PARENT-ION SCANNING TECHNIQUES [J].
CASETTA, B ;
GAROFOLO, F .
ORGANIC MASS SPECTROMETRY, 1994, 29 (10) :517-525
[5]   Determination of explosives and some metabolites of TNT in biological and environmental samples by liquid chromatography on a mixed-mode C-18-anion column [J].
Caton, JE ;
Griest, WH .
JOURNAL OF LIQUID CHROMATOGRAPHY & RELATED TECHNOLOGIES, 1996, 19 (04) :661-677
[6]   A NEW NONISOTOPIC DETECTION SYSTEM FOR IMMUNOASSAYS [J].
DEAVER, DR .
NATURE, 1995, 377 (6551) :758-760
[7]  
EKINS RP, 1997, PRINCIPLES PRACTICE, P173
[8]  
FETTEROLF DD, 1991, J FORENSIC SCI, V36, P343
[9]   Influence of antibody valency in a displacement immunoassay for the quantitation of 2,4-dichlorophenoxyacetic acid [J].
Gerdes, M ;
Meusel, M ;
Spener, F .
JOURNAL OF IMMUNOLOGICAL METHODS, 1999, 223 (02) :217-226
[10]   Conjugation of luminescent quantum dots with antibodies using an engineered adaptor protein to provide new reagents for fluoroimmunoassays [J].
Goldman, ER ;
Anderson, GP ;
Tran, PT ;
Mattoussi, H ;
Charles, PT ;
Mauro, JM .
ANALYTICAL CHEMISTRY, 2002, 74 (04) :841-847