Three phosphor plate systems and film compared for imaging root canals

被引:20
作者
Shearer, AC
Mullane, E
Macfarlane, TV
Gröndahl, HG
Horner, K
机构
[1] Univ Manchester, Turner Dent Sch, Manchester, Lancs, England
[2] Univ Gothenburg, Fac Odontol, Gothenburg, Sweden
关键词
digital imaging; radiology; root canals;
D O I
10.1046/j.1365-2591.2001.00380.x
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Aim The aim of this study was to compare three phosphor plate intraoral imaging systems (Digora (DA), Digident (DT), Denoptix (DX)) and E-speed conventional film (CF) for the imaging of root canals. Methodology Sixty extracted permanent teeth were exposed using CF, DA, DT and DX. The length of root canal visible from its most apical extent to a line drawn at the level of the cementoenamel junction was measured and this was expressed as a percentage of the distance between the radiographic apex and the cementoenamel line. All images were examined concurrently by two examiners. Films were viewed under standardized conditions and DA, DT and DX images were viewed directly from the monitor screen. The images on the monitor were enhanced to give the subjectively dearest image. Results The mean percentage of canal visible on CF was 90%, DA 78%, DT 81% and DX 83%. The difference was significant for CF-DA (P < 0.001) and CF-DT (P = 0.001). There was no statistically significant difference for CF-DX or between any of the three phosphor plate imaging systems. Conclusions It is concluded that a greater length of root canal was visible on conventional film than on three phosphor plate imaging systems and that this may be of clinical significance.
引用
收藏
页码:275 / 279
页数:5
相关论文
共 18 条
[1]   Detectability of artificial periapical lesions using direct digital and conventional radiography [J].
Barbat, J ;
Messer, HH .
JOURNAL OF ENDODONTICS, 1998, 24 (12) :837-842
[2]   Subjective image quality of solid-state and photostimulable phosphor systems for digital intra-oral radiography [J].
Borg, E ;
Attaelmanan, A ;
Gröndahl, HG .
DENTOMAXILLOFACIAL RADIOLOGY, 2000, 29 (02) :70-75
[3]   The imaging performance of a storage phosphor system for dental radiography [J].
Brettle, DS ;
Workman, A ;
Ellwood, RP ;
Launders, JH ;
Horner, K ;
Davies, RM .
BRITISH JOURNAL OF RADIOLOGY, 1996, 69 (819) :256-261
[4]   Endodontic working length assessment - Comparison of storage phosphor digital imaging and radiographic film [J].
Cederberg, RA ;
Tidwell, E ;
Frederiksen, NL ;
Benson, BW .
ORAL SURGERY ORAL MEDICINE ORAL PATHOLOGY ORAL RADIOLOGY AND ENDODONTICS, 1998, 85 (03) :325-328
[5]   Influence of the digital image display monitor on observer performance [J].
Cederberg, RA ;
Frederiksen, NL ;
Benson, BW ;
Shulman, JD .
DENTOMAXILLOFACIAL RADIOLOGY, 1999, 28 (04) :203-207
[6]   Comparison of linear measurements made from storage phosphor and dental radiographs [J].
Conover, GL ;
Hildebolt, CF ;
YokoyamaCrothers, N .
DENTOMAXILLOFACIAL RADIOLOGY, 1996, 25 (05) :268-273
[7]   Sensitometric and image quality performance of ''rapid'' intraoral film processing techniques [J].
Czajka, J ;
Rushton, VE ;
Shearer, AC ;
Horner, K .
BRITISH JOURNAL OF RADIOLOGY, 1996, 69 (817) :49-58
[8]  
DUNN G, 1995, CLIN BIOSTATISTICS I
[9]   Comparison of a photostimulable phosphor system with film for dental radiology [J].
Huda, W ;
Rill, LN ;
Benn, DK ;
Pettigrew, JC .
ORAL SURGERY ORAL MEDICINE ORAL PATHOLOGY ORAL RADIOLOGY AND ENDODONTICS, 1997, 83 (06) :725-731
[10]   Detection of approximal caries with a storage phosphor system. A comparison of enhanced digital images with dental X-ray film [J].
Moystad, A ;
Svanaes, DB ;
Risnes, S ;
Larheim, TA ;
Grondahl, HG .
DENTOMAXILLOFACIAL RADIOLOGY, 1996, 25 (04) :202-206