Endodontic working length assessment - Comparison of storage phosphor digital imaging and radiographic film

被引:33
作者
Cederberg, RA
Tidwell, E
Frederiksen, NL
Benson, BW
机构
[1] Texas A&M Univ Syst, Baylor Coll Dent, Dept Diagnost Sci, Dallas, TX 75266 USA
[2] Texas A&M Univ Syst, Baylor Coll Dent, Dept Restorat Sci, Dallas, TX 75266 USA
来源
ORAL SURGERY ORAL MEDICINE ORAL PATHOLOGY ORAL RADIOLOGY AND ENDODONTICS | 1998年 / 85卷 / 03期
关键词
D O I
10.1016/S1079-2104(98)90017-8
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Objective. This study compared the difference in interpretation of the position of endodontic file tips between two imaging systems: photostimulable storage phosphor luminescence imaging versus radiographic film. Study design. Thirteen patients were selected at random. Preoperative and trial file length radiographs were made with a dual image receptor composed of a Digora Digital Imaging Plate and a piece of Ektaspeed Plus film. Exposure techniques for E-speed film were used. Root length and file length measurements were made from digital images with the Digora system's measuring tools. Measurements were also made on radiographic film with a 7x measuring magnifier. Root length, file length, and their difference were compared for both film and digital images. Results. Differences were found to be less in digital than in film images. Photostimulable storage phosphor luminescence imaging performed similarly to Ektaspeed Plus film for measuring root lengths, but file tip positions (especially of small file sizes) were difficult to visualize with E-speed film. Conclusions. The smaller difference between file tip and root apex found with digital imaging suggests that this technique is more accurate to assess trial file length. This imaging modality for assessing file positions during root canal treatment may be beneficial to the practitioner.
引用
收藏
页码:325 / 328
页数:4
相关论文
共 15 条
[1]   AN EVALUATION OF XERORADIOGRAPHS AND RADIOGRAPHS IN LENGTH DETERMINATION IN ENDODONTICS [J].
BARKHORDAR, RA ;
NICHOLSON, RJ ;
NGUYEN, NT ;
ABBASI, J .
ORAL SURGERY ORAL MEDICINE ORAL PATHOLOGY ORAL RADIOLOGY AND ENDODONTICS, 1987, 64 (06) :747-750
[2]   The imaging performance of a storage phosphor system for dental radiography [J].
Brettle, DS ;
Workman, A ;
Ellwood, RP ;
Launders, JH ;
Horner, K ;
Davies, RM .
BRITISH JOURNAL OF RADIOLOGY, 1996, 69 (819) :256-261
[3]   Comparison of linear measurements made from storage phosphor and dental radiographs [J].
Conover, GL ;
Hildebolt, CF ;
YokoyamaCrothers, N .
DENTOMAXILLOFACIAL RADIOLOGY, 1996, 25 (05) :268-273
[4]   THE POSITION AND TOPOGRAPHY OF THE APICAL CANAL CONSTRICTION AND APICAL FORAMEN [J].
DUMMER, PMH ;
MCGINN, JH ;
REES, DG .
INTERNATIONAL ENDODONTIC JOURNAL, 1984, 17 (04) :192-198
[5]  
Gratt B M, 1979, J Endod, V5, P266, DOI 10.1016/S0099-2399(79)80172-7
[6]   COMPARISON OF 3 IMAGING TECHNIQUES FOR ASSESSING ENDODONTIC WORKING LENGTH [J].
GRIFFITHS, BM ;
BROWN, JE ;
HYATT, AT ;
LINNEY, AD .
INTERNATIONAL ENDODONTIC JOURNAL, 1992, 25 (06) :279-287
[7]   RADIOGRAPHIC DETERMINATION OF CANAL LENGTH - DIRECT DIGITAL RADIOGRAPHY VERSUS CONVENTIONAL RADIOGRAPHY [J].
HEDRICK, RT ;
DOVE, SB ;
PETERS, DD ;
MCDAVID, WD .
JOURNAL OF ENDODONTICS, 1994, 20 (07) :320-326
[8]   Comparison of a photostimulable phosphor system with film for dental radiology [J].
Huda, W ;
Rill, LN ;
Benn, DK ;
Pettigrew, JC .
ORAL SURGERY ORAL MEDICINE ORAL PATHOLOGY ORAL RADIOLOGY AND ENDODONTICS, 1997, 83 (06) :725-731
[9]   INTERPRETATION OF ENDODONTIC FILE LENGTHS USING RADIO VISIOGRAPHY [J].
LEDDY, BJ ;
MILES, DA ;
NEWTON, CW ;
BROWN, CE .
JOURNAL OF ENDODONTICS, 1994, 20 (11) :542-545
[10]   COMPARISON OF RADIOVISIOGRAPHY WITH RADIOGRAPHIC FILM IN ROOT LENGTH DETERMINATION [J].
ONG, EY ;
FORD, TRP .
INTERNATIONAL ENDODONTIC JOURNAL, 1995, 28 (01) :25-29