Study of a new solid carbon paste tyrosinase-modified amperometric biosensor for the determination of catecholamines by high-performance liquid chromatography

被引:36
作者
Pravda, M
Petit, C
Michotte, Y
Kauffmann, JM
Vytras, K
机构
[1] FREE UNIV BRUSSELS, INST PHARMACEUT, B-1050 BRUSSELS, BELGIUM
[2] FREE UNIV BRUSSELS, INST PHARMACEUT, DEPT PHARMACEUT CHEM & DRUG ANAL, B-1090 BRUSSELS, BELGIUM
[3] UNIV PARDUBICE, FAC CHEM TECHNOL, DEPT ANALYT CHEM, CR-53210 PARDUBICE, CZECH REPUBLIC
关键词
biosensors; electrochemical detection; detectors; LC; solid carbon paste electrode; tyrosine-modified electrode; enzyme-immobilized electrodes; catecholamines; dopamine; 3,4-dihydrophenylacetic acid; norepinephrine; homovanillic acid;
D O I
10.1016/0021-9673(95)01103-X
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
The performance of a tyrosinase-modified ''solid carbon paste'' electrode (SCPE) as electrochemical detector has been studied in comparison with a glassy carbon electrode detector in high-performance liquid chromatography for the simultaneous determination of dopamine, 3,4-dihydroxyphenylacetic acid, norepinephrine and homovanillic acid. The influence of pH, flow-rate and amount of organic solvent in the mobile phase on the biosensor response was investigated. The stability and selectivity of the detector were significantly affected by the mobile phase pH. No effect of 2% isopropanol in the mobile phase was observed. The biosensor response was fast, reproducible, highly sensitive and linear over the concentration range 0.09 mu M(-1) mM (detection limit of ca. 290 pg of neurotransmitter injected).
引用
收藏
页码:47 / 54
页数:8
相关论文
共 39 条
[1]  
[Anonymous], 1986, Clarke's isolation and identification of drugs in pharmaceuticals, body fluids, and post-mortem material
[2]  
ASONZU MU, 1990, ANAL CHEM, V62, P708
[3]   CHEMICALLY MODIFIED ELECTRODES IN LIQUID-CHROMATOGRAPHY DETECTION - A REVIEW [J].
BALDWIN, RP ;
THOMSEN, KN .
TALANTA, 1991, 38 (01) :1-16
[4]   ELECTROCHEMICAL IMMOBILIZATION OF ENZYMES .3. IMMOBILIZATION OF GLUCOSE-OXIDASE IN THIN-FILMS OF ELECTROCHEMICALLY POLYMERIZED PHENOLS [J].
BARTLETT, PN ;
TEBBUTT, P ;
TYRRELL, CH .
ANALYTICAL CHEMISTRY, 1992, 64 (02) :138-142
[5]  
BARTLETT PN, 1993, J ELECTROANAL CHEM, V362, P1
[6]   MODIFICATION OF ELECTRODE SURFACES WITH OXIDIZED PHENOLS TO CONFER SELECTIVITY TO AMPEROMETRIC BIOSENSORS FOR GLUCOSE DETERMINATION [J].
CHRISTIE, IM ;
VADGAMA, P ;
LLOYD, S .
ANALYTICA CHIMICA ACTA, 1993, 274 (02) :191-199
[7]   TISSUE-BASED AND MICROBE-BASED ELECTROCHEMICAL DETECTORS FOR LIQUID-CHROMATOGRAPHY [J].
CONNOR, MP ;
WANG, J ;
KUBIAK, W ;
SMYTH, MR .
ANALYTICA CHIMICA ACTA, 1990, 229 (01) :139-143
[8]   AMPEROMETRIC GLUCOSE SENSOR WITH FERROCENE AS AN ELECTRON-TRANSFER MEDIATOR [J].
DONG, SJ ;
WANG, BX ;
LIU, BF .
BIOSENSORS & BIOELECTRONICS, 1992, 7 (03) :215-222
[9]   AMPEROMETRIC DETERMINATION OF DOPAMINE ON AN ENZYMATICALLY MODIFIED CARBON-PASTE ELECTRODE [J].
FORZANI, ES ;
RIVAS, GA ;
SOLIS, VM .
JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 1995, 382 (1-2) :33-40
[10]   CARBON-PASTE ELECTRODES MODIFIED WITH ENZYMES, TISSUES, AND CELLS [J].
GORTON, L .
ELECTROANALYSIS, 1995, 7 (01) :23-45