Stroke volume and pulse pressure variation for prediction of fluid responsiveness in patients undergoing off-pump coronary artery bypass grafting

被引:201
作者
Hofer, CK
Müller, SM
Furrer, L
Klaghofer, R
Genoni, M
Zollinger, A
机构
[1] Triiemli City Hosp, Inst Anesthesiol & Intens Care Med, CH-8063 Zurich, Switzerland
[2] Univ Zurich Hosp, Dept Psychosocial Med, CH-8091 Zurich, Switzerland
[3] Univ Zurich Hosp, Dept Cardiac Surg, CH-8091 Zurich, Switzerland
关键词
cardiac preload assessment; cardiac surgery; pulse contour analysis; pulse pressure variation; stroke volume variation;
D O I
10.1378/chest.128.2.848
中图分类号
R4 [临床医学];
学科分类号
1002 ; 100602 ;
摘要
Study objectives: Stroke volume variation (SVV) and pulse pressure variation (PPV) determined by the PiCCOplus system (Pulsion Medical Systems; Munich, Germany) may be useful dynamic variables in guiding fluid therapy in patients receiving mechanical ventilation. However, with respect to the prediction of volume responsiveness, conflicting results for SW have been published in cardiac surgery patients. The goal of this study was to reevaluate SW in predicting volume responsiveness and to compare it with PPV. Design: Prospective nonrandomized clinical investigation. Setting: University-based cardiac surgery. Patients: Forty patients with preserved left ventricular function undergoing elective off-pump coronary artery bypass grafting. Interventions: Volume replacement therapy before surgery. Measurements and results: Following induction of anesthesia, before and after volume replacement (6% hydroxyethyl starch solution, 10 mL/kg ideal body weight), hemodynamic measurements of stroke volume index (SVI), SVV, PPV, global end-diastolic volume index (GEDVI), central venous pressure (CVP) and pulmonary capillary wedge pressure (PCWP) were obtained. Also, left ventricular end-diastolic area index (LVEDAI) was assessed by transesophageal echocardiography. Prediction of ventricular performance was tested by calculating the area under the receiver operating characteristic (ROC) curves and by linear regression analysis; p < 0.05 was considered significant. All measured hemodynamic variables except heart rate changed significantly after fluid loading. GEDVI, CVP, PCWP, and LVEDAI increased, whereas SW and PPV decreased. The best area under the ROC curve (AUC) was found for SW (AUC = 0.823) and PPV (AUC = 0.808); the AUC for other preload indexes ranged from 0.493 to 0.636. A significant correlation with changes of SVI was observed for SW (r = 0.606, p < 0.001) and PPV (r = 0.612, p < 0.001) only. SW and PPV were closely related (r = 0.861, p < 0.001). Conclusions: In contrast to standard preload indexes, SW and PPV, comparably, showed a good performance in predicting fluid responsiveness in patients before off-pump coronary artery bypass grafting.
引用
收藏
页码:848 / 854
页数:7
相关论文
共 27 条
[1]   Fluid responsiveness in mechanically ventilated patients: a review of indices used in intensive care [J].
Bendjelid, K ;
Romand, JA .
INTENSIVE CARE MEDICINE, 2003, 29 (03) :352-360
[2]  
Berkenstadt H, 2001, ANESTH ANALG, V92, P984
[3]  
Buhre W, 2001, EUR J ANAESTH, V18, P662
[4]   Determinants of aortic pressure variation during positive-pressure ventilation in man [J].
Denault, AY ;
Gasior, TA ;
Gorcsan, J ;
Mandarino, WA ;
Deneault, LG ;
Pinsky, MR .
CHEST, 1999, 116 (01) :176-186
[5]  
DUBOIS D, 1989, NUTRITION, V5, P303
[6]   Respiratory changes in aortic blood velocity as an indicator of fluid responsiveness in ventilated patients with septic shock [J].
Feissel, M ;
Michard, F ;
Mangin, I ;
Ruyer, O ;
Faller, JP ;
Teboul, JL .
CHEST, 2001, 119 (03) :867-873
[7]   Comparison of pulmonary arterial thermodilution and arterial pulse contour analysis: Evaluation of a new algorithm [J].
Felbinger, TW ;
Reuter, DA ;
Eltzschig, HK ;
Moerstedt, K ;
Goedje, O ;
Goetz, AE .
JOURNAL OF CLINICAL ANESTHESIA, 2002, 14 (04) :296-301
[8]  
Gödje O, 2002, CRIT CARE MED, V30, P52
[9]   Continuous cardiac output by femoral arterial thermodilution calibrated pulse contour analysis: Comparison with pulmonary arterial thermodilution [J].
Goedje, O ;
Hoeke, K ;
Lichtwarck-Aschoff, M ;
Faltchauser, A ;
Lamm, P ;
Reichart, B .
CRITICAL CARE MEDICINE, 1999, 27 (11) :2407-2412
[10]  
Gunn S R, 2001, Curr Opin Crit Care, V7, P212