Stroke volume and pulse pressure variation for prediction of fluid responsiveness in patients undergoing off-pump coronary artery bypass grafting

被引:201
作者
Hofer, CK
Müller, SM
Furrer, L
Klaghofer, R
Genoni, M
Zollinger, A
机构
[1] Triiemli City Hosp, Inst Anesthesiol & Intens Care Med, CH-8063 Zurich, Switzerland
[2] Univ Zurich Hosp, Dept Psychosocial Med, CH-8091 Zurich, Switzerland
[3] Univ Zurich Hosp, Dept Cardiac Surg, CH-8091 Zurich, Switzerland
关键词
cardiac preload assessment; cardiac surgery; pulse contour analysis; pulse pressure variation; stroke volume variation;
D O I
10.1378/chest.128.2.848
中图分类号
R4 [临床医学];
学科分类号
1002 ; 100602 ;
摘要
Study objectives: Stroke volume variation (SVV) and pulse pressure variation (PPV) determined by the PiCCOplus system (Pulsion Medical Systems; Munich, Germany) may be useful dynamic variables in guiding fluid therapy in patients receiving mechanical ventilation. However, with respect to the prediction of volume responsiveness, conflicting results for SW have been published in cardiac surgery patients. The goal of this study was to reevaluate SW in predicting volume responsiveness and to compare it with PPV. Design: Prospective nonrandomized clinical investigation. Setting: University-based cardiac surgery. Patients: Forty patients with preserved left ventricular function undergoing elective off-pump coronary artery bypass grafting. Interventions: Volume replacement therapy before surgery. Measurements and results: Following induction of anesthesia, before and after volume replacement (6% hydroxyethyl starch solution, 10 mL/kg ideal body weight), hemodynamic measurements of stroke volume index (SVI), SVV, PPV, global end-diastolic volume index (GEDVI), central venous pressure (CVP) and pulmonary capillary wedge pressure (PCWP) were obtained. Also, left ventricular end-diastolic area index (LVEDAI) was assessed by transesophageal echocardiography. Prediction of ventricular performance was tested by calculating the area under the receiver operating characteristic (ROC) curves and by linear regression analysis; p < 0.05 was considered significant. All measured hemodynamic variables except heart rate changed significantly after fluid loading. GEDVI, CVP, PCWP, and LVEDAI increased, whereas SW and PPV decreased. The best area under the ROC curve (AUC) was found for SW (AUC = 0.823) and PPV (AUC = 0.808); the AUC for other preload indexes ranged from 0.493 to 0.636. A significant correlation with changes of SVI was observed for SW (r = 0.606, p < 0.001) and PPV (r = 0.612, p < 0.001) only. SW and PPV were closely related (r = 0.861, p < 0.001). Conclusions: In contrast to standard preload indexes, SW and PPV, comparably, showed a good performance in predicting fluid responsiveness in patients before off-pump coronary artery bypass grafting.
引用
收藏
页码:848 / 854
页数:7
相关论文
共 27 条
[11]   A METHOD OF COMPARING THE AREAS UNDER RECEIVER OPERATING CHARACTERISTIC CURVES DERIVED FROM THE SAME CASES [J].
HANLEY, JA ;
MCNEIL, BJ .
RADIOLOGY, 1983, 148 (03) :839-843
[12]   POOR CORRELATION BETWEEN PULMONARY ARTERIAL WEDGE PRESSURE AND LEFT-VENTRICULAR END-DIASTOLIC VOLUME AFTER CORONARY-ARTERY BYPASS GRAFT-SURGERY [J].
HANSEN, RM ;
VIQUERAT, CE ;
MATTHAY, MA ;
WIENERKRONISH, JP ;
DEMARCO, T ;
BAHTIA, S ;
MARKS, JD ;
BOTVINICK, EH ;
CHATTERJEE, K .
ANESTHESIOLOGY, 1986, 64 (06) :764-770
[13]   Off-pump coronary artery surgery [J].
Heames, RM ;
Gill, RS ;
Ohri, SK ;
Hett, DA .
ANAESTHESIA, 2002, 57 (07) :676-685
[14]   CYCLIC CHANGES IN ARTERIAL PULSE DURING RESPIRATORY SUPPORT [J].
JARDIN, F ;
FARCOT, JC ;
GUERET, P ;
PROST, JF ;
OZIER, Y ;
BOURDARIAS, JP .
CIRCULATION, 1983, 68 (02) :266-274
[15]   Pulmonary artery occlusion pressure and central venous pressure fail to predict ventricular filling volume, cardiac performance, or the response to volume infusion in normal subjects [J].
Kumar, A ;
Anel, R ;
Bunnell, E ;
Habet, K ;
Zanotti, S ;
Marshall, S ;
Neumann, A ;
Ali, A ;
Cheang, M ;
Kavinsky, C ;
Parrillo, JE .
CRITICAL CARE MEDICINE, 2004, 32 (03) :691-699
[16]   Assessing fluid responsiveness by stroke volume variation in mechanically ventilated patients with severe sepsis [J].
Marx, G ;
Cope, T ;
McCrossan, L ;
Swaraj, S ;
Cowan, C ;
Mostafa, SM ;
Wenstone, R ;
Leuwer, M .
EUROPEAN JOURNAL OF ANAESTHESIOLOGY, 2004, 21 (02) :132-138
[17]   Using heart-lung interactions to assess fluid responsiveness during mechanical ventilation [J].
Michard, F ;
Teboul, JL .
CRITICAL CARE, 2000, 4 (05) :282-289
[18]   Predicting fluid responsiveness in ICU patients - A critical analysis of the evidence [J].
Michard, F ;
Teboul, JL .
CHEST, 2002, 121 (06) :2000-2008
[19]   Relation between respiratory changes in arterial pulse pressure and fluid responsiveness in septic patients with acute circulatory failure [J].
Michard, F ;
Boussat, S ;
Chemla, D ;
Anguel, N ;
Mercat, A ;
Lecarpentier, Y ;
Richard, C ;
Pinsky, MR ;
Teboul, JL .
AMERICAN JOURNAL OF RESPIRATORY AND CRITICAL CARE MEDICINE, 2000, 162 (01) :134-138
[20]   Assessing fluid responsiveness by the systolic pressure variation in mechanically ventilated patients - Systolic pressure variation as a guide to fluid therapy in patients with sepsis-induced hypotension [J].
Perel, A .
ANESTHESIOLOGY, 1998, 89 (06) :1309-1310