Stripping voltammetric determination of Pb(II) and Cd(II) based on the multiwalled carbon nanotubes-Nafion-bismuth modified glassy carbon electrodes

被引:53
作者
Wang, Na [1 ]
Dong, Xiandui [1 ]
机构
[1] Chinese Acad Sci, Grad Sch, Changchun Inst Appl Chem, State Key Lab Electroanalyt Chem, Changchun, Peoples R China
关键词
anodic stripping voltammetry; bismuth; carbon nanotubes; Cd(II); Nafion; Pb(II);
D O I
10.1080/00032710802052817
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
In this work, a new method for the simultaneous determination of Pb(II) and Cd(II) on the multiwalled carbon nanotubes (MWNT)-Nafion-bismuth modified glassy carbon electrode (GCE) using square-wave anodic stripping voltammetry has been studied. Scanning electron microscopy was used to investigate the characteristics of the MWNT-Nafion-bismuth modified GCE. Well-defined sharp stripping peaks were observed in the determination of Pb(II) and Cd(II) simultaneously on this electrode. Under optimized conditions, the lowest detectable concentrations were 50 ng/l for Pb(II) and 80 ng/l for Cd(II) under a 10 min preconcentration. The attractive performances of MWNT-Nafion-bismuth modified GCE demonstrated its application for a simple, rapid, and harmless determination of trace heavy metals.
引用
收藏
页码:1267 / 1278
页数:12
相关论文
共 31 条
[1]   Fibrinogen-coated bismuth film electrodes for voltammetric analysis of lead and cadmium using the batch injection analysis [J].
Adraoui, I. ;
Rhazi, M. E. ;
Amine, A. .
ANALYTICAL LETTERS, 2007, 40 (02) :349-367
[2]   Nanotubes from carbon [J].
Ajayan, PM .
CHEMICAL REVIEWS, 1999, 99 (07) :1787-1799
[3]   Sonoelectroanalysis: investigation of bismuth-film-modified glassy carbon electrodes [J].
Banks, CE ;
Kruusma, J ;
Hyde, ME ;
Salimi, A ;
Compton, RG .
ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2004, 379 (02) :277-282
[4]   Nafion-coated bismuth film and Nafion-coated mercury film electrodes for anodic stripping voltammetry combined on-line with ICP-mass spectrometry [J].
Cao, Grace X. ;
Jimenez, Omar ;
Zhou, Feimeng ;
Xu, Maotian .
JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY, 2006, 17 (07) :945-952
[5]  
CARIDADE CG, 2006, ELECTROANAL, V18, P854
[6]   A study on the utility of bismuth-film electrodes for the determination of In(III) in the presence of Pb(II) and Cd(II) by square wave anodic stripping voltammetry [J].
Charalambous, A ;
Economou, A .
ANALYTICA CHIMICA ACTA, 2005, 547 (01) :53-58
[7]   A study of pencil-lead bismuth-film electrodes for the determination of trace metals by anodic stripping voltammetry [J].
Demetriades, D ;
Economou, A ;
Voulgaropoulos, A .
ANALYTICA CHIMICA ACTA, 2004, 519 (02) :167-172
[8]   Mercury film electrodes: developments, trends and potentialities for electroanalysis [J].
Economou, A ;
Fielden, PR .
ANALYST, 2003, 128 (03) :205-212
[9]   Bismuth-film electrodes: recent developments and potentialities for electroanalysis [J].
Economou, A .
TRAC-TRENDS IN ANALYTICAL CHEMISTRY, 2005, 24 (04) :334-340
[10]  
FLORENCE TM, 1970, J ELECTROANAL CHEM, V27, P273, DOI 10.1016/S0022-0728(70)80189-9