Stability-indicating assay of sodium cromoglicate in ophthalmic solution using mixed-mode hydrophilic interaction chromatography

被引:12
作者
Ali, Mohammed Shahid [1 ]
Rafiuddin, Syed [1 ]
Al-Jawi, Dalya Abdullah [1 ]
Al-Hetari, Yasmin [1 ]
Ghori, Mohsin Ul Haq [1 ]
Khatri, Aamer Roshanali [1 ]
机构
[1] Jamjoom Pharmaceut Co Ltd, Jeddah 21442, Saudi Arabia
关键词
hydrophilic interaction chromatography; method validation; sodium cromoglicate; retention mechanism;
D O I
10.1002/jssc.200700534
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A hydrophilic interaction chromatographic (HILIC) procedure for the quantification of Sodium Cromoglicate (SCG) in ophthalmic solution is developed. Mobile phase consists of ACN and buffer, 86:14 v/v. Atlantis HILIC-Si column, 25 cm x 4.6 mm, is used as stationary phase. Detection is carried out using a variable wavelength UV-Vis detector at 326 nm. Linearity range and percent recoveries for SCG were 50400 mu g/mL and 100.44%, respectively. The SCG HILIC-UV assay was validated according to the International Conference on Harmonization guidelines. The method separates two impurities and degradation products resulting from stress environment. Influence of organic solvent, ionic strength and mobile phase pH on the retention of SCG is studied. The paper provides optimization of polar anionic solute (SCG) on unmodified silica by HILIC. Proposed method can be used as a stability-indicating assay for SGC and can be proved to be beneficial in ESI-MS for enhanced sensitivity.
引用
收藏
页码:1645 / 1650
页数:6
相关论文
共 29 条
[21]  
RADULOVIC D, 1994, FARMACO, V49, P375
[22]  
REYNOLDS JEF, 1996, MARTINDALE EXTRA
[23]   High performance liquid chromatographic determination of sodium cromoglycate [J].
Segall, A ;
Vitale, F ;
Ricci, R ;
Giancaspro, G ;
Pizzorno, MT .
DRUG DEVELOPMENT AND INDUSTRIAL PHARMACY, 1997, 23 (08) :839-842
[24]   Simple means to alleviate sensitivity loss by trifluoroacetic acid (TFA) mobile phases in the hydrophilic interaction chromatography-electro, spray tandem mass spectrometric (HILIC-ESI/MS/MS) bioanalysis of basic compounds [J].
Shou, WZ ;
Weng, ND .
JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2005, 825 (02) :186-192
[25]   Ultrafast liquid chromatography/tandem mass spectrometry bioanalysis of polar analytes using packed silica columns [J].
Shou, WZ ;
Chen, YL ;
Eerkes, A ;
Tang, YQ ;
Magis, L ;
Jiang, XY ;
Weng, ND .
RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 2002, 16 (17) :1613-1621
[26]  
VOYKSNER RD, 1997, ELECTROSPRAY IONIZAT
[27]   Bioanalytical liquid chromatography tandem mass spectrometry methods on underivatized silica columns with aqueous/organic mobile phases [J].
Weng, ND .
JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2003, 796 (02) :209-224
[28]   Importance of injection solution composition for LC-MS-MS methods [J].
Weng, ND ;
Chen, YL ;
Shou, W ;
Jiang, XY .
JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2001, 26 (5-6) :753-767
[29]  
2006, US PHARMACOPOEIA, V29