Quantitative comparison and evaluation of software packages for assessment of abdominal adipose tissue distribution by magnetic resonance imaging

被引:76
作者
Bonekamp, S. [1 ]
Ghosh, P.
Crawford, S. [2 ]
Solga, S. F. [3 ]
Horska, A. [4 ]
Brancati, F. I. [5 ]
Diehl, A. M. [6 ]
Smith, S. [7 ]
Clark, J. M. [2 ,5 ]
机构
[1] Johns Hopkins Univ, Sch Med, Johns Hopkins Med Inst,Div Med Imaging Phys, Russell H Morgan Dept Radiol & Radiol Sci, Baltimore, MD 21287 USA
[2] Johns Hopkins Univ, Bloomberg Sch Publ Hlth, Baltimore, MD USA
[3] Johns Hopkins Univ, Sch Med, Dept Med, Div Gastroenterol & Hepatol, Baltimore, MD 21205 USA
[4] Johns Hopkins Univ, Sch Med, Div Neuroradiol, Russell H Morgan Dept Radiol & Radiol Sci, Baltimore, MD USA
[5] Johns Hopkins Univ, Sch Med, Dept Med, Div Gen Internal Med, Baltimore, MD 21205 USA
[6] Duke Univ, Med Ctr, Div Gastroenterol, Durham, NC 27710 USA
[7] Pennington Biomed Res Ctr, Baton Rouge, LA USA
关键词
magnetic resonance imaging; abdominal adipose tissue; software evaluation; image segmentation; visceral adipose tissue; subcutaneous adipose tissue;
D O I
10.1038/sj.ijo.0803696
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Objective: To examine five available software packages for the assessment of abdominal adipose tissue with magnetic resonance imaging, compare their features and assess the reliability of measurement results. Design: Feature evaluation and test-retest reliability of softwares (NIHImage, SliceOmatic, Analyze, HippoFat and EasyVision) used in manual, semi-automated or automated segmentation of abdominal adipose tissue. Subjects: A random sample of 15 obese adults with type 2 diabetes. Measurements: Axial T1-weighted spin echo images centered at vertebral bodies of L2-L3 were acquired at 1.5 T. Five software packages were evaluated (NIHImage, SliceOmatic, Analyze, HippoFat and EasyVision), comparing manual, semi-automated and automated segmentation approaches. Images were segmented into cross-sectional area (CSA), and the areas of visceral (VAT) and subcutaneous adipose tissue (SAT). Ease of learning and use and the design of the graphical user interface (GUI) were rated. Intra-observer accuracy and agreement between the software packages were calculated using intra-class correlation. Intra-class correlation coefficient was used to obtain test -retest reliability. Results: Three of the five evaluated programs offered a semi-automated technique to segment the images based on histogram values or a user-defined threshold. One software package allowed manual delineation only. One fully automated program demonstrated the drawbacks of uncritical automated processing. The semi-automated approaches reduced variability and measurement error, and improved reproducibility. There was no significant difference in the intra-observer agreement in SAT and CSA. The VAT measurements showed significantly lower test-retest reliability. There were some differences between the software packages in qualitative aspects, such as user friendliness. Conclusion: Four out of five packages provided essentially the same results with respect to the inter- and intra-rater reproducibility. Our results using SliceOmatic, Analyze or NIHImage were comparable and could be used interchangeably. Newly developed fully automated approaches should be compared to one of the examined software packages.
引用
收藏
页码:100 / 111
页数:12
相关论文
共 72 条
[41]   Standardized assessment of whole body adipose tissue topography by MRI [J].
Machann, J ;
Thamer, C ;
Schnoedt, B ;
Haap, M ;
Haring, HU ;
Claussen, CD ;
Stumvoll, M ;
Fritsche, A ;
Schick, F .
JOURNAL OF MAGNETIC RESONANCE IMAGING, 2005, 21 (04) :455-462
[42]   DUAL-ENERGY X-RAY ABSORPTIOMETRY FOR TOTAL-BODY AND REGIONAL BONE-MINERAL AND SOFT-TISSUE COMPOSITION [J].
MAZESS, RB ;
BARDEN, HS ;
BISEK, JP ;
HANSON, J .
AMERICAN JOURNAL OF CLINICAL NUTRITION, 1990, 51 (06) :1106-1112
[43]   Abdominal fat distribution and peripheral and hepatic insulin resistance in type 2 diabetes mellitus [J].
Miyazaki, Y ;
Glass, L ;
Triplitt, C ;
Wajcberg, E ;
Mandarino, LJ ;
DeFronzo, RA .
AMERICAN JOURNAL OF PHYSIOLOGY-ENDOCRINOLOGY AND METABOLISM, 2002, 283 (06) :E1135-E1143
[44]  
Ohsuzu F, 1998, Radiat Med, V16, P99
[45]   Water-saturated three-dimensional balanced steady-state free precession for fast abdominal fat quantification [J].
Peng, Q ;
McColl, RW ;
Wang, JH ;
Chia, JM ;
Weatherall, PT .
JOURNAL OF MAGNETIC RESONANCE IMAGING, 2005, 21 (03) :263-271
[46]  
Poll LudgerWilhelm, 2004, Diabetes Technol Ther, V6, P844
[47]   A rapid and reliable semiautomated method for measurement of total abdominal fat volumes using magnetic resonance imaging [J].
Poll, LW ;
Wittsack, HJ ;
Koch, JA ;
Willers, R ;
Cohnen, M ;
Kapitza, C ;
Heinemann, L ;
Mödder, U .
MAGNETIC RESONANCE IMAGING, 2003, 21 (06) :631-636
[48]  
Poll LW, 2002, EUR J MED RES, V7, P347
[49]   An accurate and robust method for unsupervised assessment of abdominal fat by MRI [J].
Positano, V ;
Gastaldelli, A ;
Sironi, AM ;
Santarelli, MF ;
Lombardi, M ;
Landini, L .
JOURNAL OF MAGNETIC RESONANCE IMAGING, 2004, 20 (04) :684-689
[50]   Relationship of insulin sensitivity and ApoB levels to intra-abdominal fat in subjects with familial combined hyperlipidemia [J].
Purnell, JQ ;
Kahn, SE ;
Schwartz, RS ;
Brunzell, JD .
ARTERIOSCLEROSIS THROMBOSIS AND VASCULAR BIOLOGY, 2001, 21 (04) :567-572