Renewable-surface graphite-ceramic enzyme sensors for the determination of hypoxanthine in fish meat

被引:27
作者
Niu, JJ [1 ]
Lee, JY [1 ]
机构
[1] Natl Univ Singapore, Dept Chem & Environm Engn, Singapore, Singapore
来源
ANALYTICAL COMMUNICATIONS | 1999年 / 36卷 / 03期
关键词
D O I
10.1039/a900896i
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Sol-gel processes were used to fabricate amperometric biosensors that are active for hypoxanthine (Hx) determination. Xanthine oxidase was immobilized in the bulk of the silica-graphite matrix (SGM) to produce electrodes where new surfaces can be generated on demand by mechanical polishing. The immobilized enzyme electrodes can be used in unmediated hydrogen peroxide oxidation mode, or in unmediated and mediated oxygen reduction mode, to result in three different types of Hx biosensors with detection limits of 1.3 x 10(-6), 5.6 x 10(-6) and 3.8 x 10(-7) M, respectively. Benzyl viologen was used as the charge transfer mediator to enhance the response in the hydrogen peroxide production mode. The sensors show good linear response over a wide range of concentrations of about 1 x 10(-6)-1 x 10(-3) M. The use of bulk immobilization and the possibility of renewable surfaces have enabled the easy operation of these sensors with high stability. The experimental results from a carp sample stored under different conditions demonstrate the practicality of these sensors as simple, rapid and cost effective measurement of fish meat freshness.
引用
收藏
页码:81 / 83
页数:3
相关论文
共 19 条
[1]   ORGANIC-CHEMISTRY WITHIN CERAMIC MATRICES - DOPED SOL-GEL MATERIALS [J].
AVNIR, D .
ACCOUNTS OF CHEMICAL RESEARCH, 1995, 28 (08) :328-334
[2]   Sol-gel-derived nanocrystalline gold-silicate composite biosensor [J].
Bharathi, S ;
Lev, O .
ANALYTICAL COMMUNICATIONS, 1998, 35 (01) :29-31
[3]  
Cass A. E. G., 1990, BIOSENSORS PRACTICAL
[4]  
*DEP SCI IND RES, 1959, TORR RES STAT ANN RE
[5]   THE SOL-GEL PROCESS [J].
HENCH, LL ;
WEST, JK .
CHEMICAL REVIEWS, 1990, 90 (01) :33-72
[6]   Development of a hypoxanthine biosensor based on immobilized xanthine oxidase chemically modified electrode [J].
Hu, SS ;
Liu, CC .
ELECTROANALYSIS, 1997, 9 (05) :372-377
[7]   THE SEPARATION AND DETERMINATION OF FREE PURINES, PYRIMIDINES AND NUCLEOSIDE IN COD MUSCLE [J].
JONES, NR .
ANALYST, 1960, 85 (1007) :111-115
[8]   DETERMINATION OF FISH FRESHNESS WITH AN ENZYME SENSOR SYSTEM [J].
KARUBE, I ;
MATSUOKA, H ;
SUZUKI, S ;
WATANABE, E ;
TOYAMA, K .
JOURNAL OF AGRICULTURAL AND FOOD CHEMISTRY, 1984, 32 (02) :314-319
[9]  
Kilinc E, 1998, ELECTROANAL, V10, P273, DOI 10.1002/(SICI)1521-4109(199804)10:4<273::AID-ELAN273>3.0.CO
[10]  
2-O