Computed tomography and radiation risks: What pediatric health care providers should know

被引:415
作者
Frush, DP
Donnelly, LF
Rosen, NS
机构
[1] Duke Univ, Med Ctr, Dept Radiol,Div Pediat Radiol, McGovern Davison Childrens Hlth Ctr 1905, Durham, NC 27710 USA
[2] Cincinnati Childrens Hosp Med Ctr, Dept Radiol, Cincinnati, OH USA
[3] Mem Sloan Kettering Canc Ctr, Dept Radiol, New York, NY 10021 USA
关键词
CT; infants and children; helical CT; radiation dose;
D O I
10.1542/peds.112.4.951
中图分类号
R72 [儿科学];
学科分类号
100202 ;
摘要
Computed tomography (CT) is an extremely valuable diagnostic tool. Recent advances, particularly multidetector technology, have provided increased and more diverse applications. However, there is also the potential for inappropriate use and unnecessary radiation dose. Because some data indicate that low-dose radiation ( such as that in CT) may have a significant risk of cancer, especially in young children, it is important to limit CT radiation by following the ALARA ( as low as reasonably achievable) principle. There is a variety of strategies to limit radiation dose, including performing only necessary examinations, limiting the region of coverage, and adjusting individual CT settings based on indication, region imaged, and size of the child. The pediatric health care provider has a pivotal role in the performance of CT and may be the only individual who discusses these important CT radiation issues with the child and family. For this reason, this article will summarize the issues with CT patterns of use and radiation risk, and provide dose reduction strategies pertinent to pediatric health care providers.
引用
收藏
页码:951 / 957
页数:7
相关论文
共 47 条
[11]   Lessons from history [J].
Donnelly, LF .
PEDIATRIC RADIOLOGY, 2002, 32 (04) :287-292
[12]   Minimizing radiation dose for pediatric body applications of single-detector helical CT: Strategies at a large children's hospital [J].
Donnelly, LF ;
Emery, KH ;
Brody, AS ;
Laor, T ;
Gylys-Morin, VM ;
Anton, CG ;
Thomas, SR ;
Frush, DP .
AMERICAN JOURNAL OF ROENTGENOLOGY, 2001, 176 (02) :303-306
[13]  
Feinendegen LE, 2001, J NUCL MED, V42, p17N
[14]   In-plane bismuth breast shields for pediatric CT: Effects on radiation dose and image quality using experimental and clinical data [J].
Fricke, BL ;
Donnelly, LF ;
Frush, DP ;
Yoshizumi, T ;
Varchena, V ;
Poe, SA ;
Lucaya, J .
AMERICAN JOURNAL OF ROENTGENOLOGY, 2003, 180 (02) :407-411
[15]   Helical CT in children: Technical considerations and body applications [J].
Frush, DP ;
Donnelly, LF .
RADIOLOGY, 1998, 209 (01) :37-48
[16]   Pediatric CT: practical approach to diminish the radiation dose [J].
Frush, DP .
PEDIATRIC RADIOLOGY, 2002, 32 (10) :714-717
[17]   Computer-simulated radiation dose reduction for abdominal multidetector CT of pediatric patients [J].
Frush, DP ;
Slack, CC ;
Hollingsworth, CL ;
Bisset, GS ;
Donnelly, LF ;
Hsieh, J ;
Lavin-Wensell, T ;
Mayo, JR .
AMERICAN JOURNAL OF ROENTGENOLOGY, 2002, 179 (05) :1107-1113
[18]   Improved pediatric multidetector body CT using a size-based color-coded format [J].
Frush, DP ;
Soden, B ;
Frush, KS ;
Lowry, C .
AMERICAN JOURNAL OF ROENTGENOLOGY, 2002, 178 (03) :721-726
[19]   Strategies of dose reduction [J].
Frush, DP .
PEDIATRIC RADIOLOGY, 2002, 32 (04) :293-297
[20]   Helical CT of the body: A survey of techniques used for pediatric patients [J].
Hollingsworth, C ;
Frush, DP ;
Cross, M ;
Lucaya, J .
AMERICAN JOURNAL OF ROENTGENOLOGY, 2003, 180 (02) :401-406