Effects of stent structure on stent flexibility measurements

被引:100
作者
Mori, K [1 ]
Saito, T [1 ]
机构
[1] Yamaguchi Univ, Grad Sch Med, Yamaguchi 7558611, Japan
关键词
stent; flexibility; four-points bending test; FEM;
D O I
10.1007/s10439-005-2807-6
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Adequate delivery and placement of intracoronary artery stents is dependent on various properties of the stent itself, including flexibility and high-radial strength. Although these properties can be assessed via determination of the bending stiffness and radial stiffness of a stent, the mesh structure of the stent does not lend easily to such measurements. The goal of the present study was to determine an optimal method for determining stent bending stiffness. The four-points bending test was used to evaluate stent flexibility, and the finite element method (FEM) was employed to assess the effect of stent structure on flexibility in stents with differing link structures. The four-points bending test yielded the following bending stiffness values: 85.28 N mm(2) for the stent with an S-shaped link; 41.67 N mm(2) for the stent with an N-shaped link; 78.79 N mm(2) for the stent with a modified W-shaped link; and 188.67 N mm(2) for the stent with a W-shaped link. The stent with the point symmetric link configuration (S-, N- and modified W-shaped link) had high flexibility. FEM analysis revealed that low flexibility resulted from interference between the struts at the compressive side. Further, the flexibility predicted from FEM analysis correlated with bending stiffness of the stents. We conclude that use of the four-points bending test yields information that is critical for the design of flexible stents.
引用
收藏
页码:733 / 742
页数:10
相关论文
共 25 条
[1]   EVALUATION OF POLY(L-LACTIC ACID) AS A MATERIAL FOR INTRAVASCULAR POLYMERIC STENTS [J].
AGRAWAL, CM ;
HAAS, KF ;
LEOPOLD, DA ;
CLARK, HG .
BIOMATERIALS, 1992, 13 (03) :176-182
[2]   Perspective: Sirolimus-eluting coronary stents. [J].
Curfman, GD .
NEW ENGLAND JOURNAL OF MEDICINE, 2002, 346 (23) :1770-1771
[3]   TRANSLUMINALLY-PLACED COILSPRING ENDARTERIAL TUBE GRAFTS - LONG-TERM PATENCY IN CANINE POPLITEAL ARTERY [J].
DOTTER, CT .
INVESTIGATIVE RADIOLOGY, 1969, 4 (05) :329-+
[4]  
DUCMOULIN C, 2000, J BIOMECH, V33, P1461
[5]   Mechanical properties of coronary stents determined by using finite element analysis [J].
Etave, F ;
Finet, G ;
Boivin, M ;
Boyer, JC ;
Rioufol, G ;
Thollet, G .
JOURNAL OF BIOMECHANICS, 2001, 34 (08) :1065-1075
[6]  
KRANZ C, 1999, PROG BIOMED RES, V4, P34
[7]  
LOSSEF SV, 1994, JVIR, V5, P314
[8]   Mechanical behavior of coronary stents investigated through the finite element method [J].
Migliavacca, F ;
Petrini, L ;
Colombo, M ;
Auricchio, F ;
Pietrabissa, R .
JOURNAL OF BIOMECHANICS, 2002, 35 (06) :803-811
[9]  
MORI K, 2001, T JPN SOC MECH ENG-C, V662, P3078
[10]   A randomized comparison of a sirolimus-eluting stent with a standard stent for coronary revascularization. [J].
Morice, M ;
Serruys, PW ;
Sousa, JE ;
Fajadet, J ;
Hayashi, EB ;
Perin, M ;
Colombo, A ;
Schuler, G ;
Barragan, P ;
Guagliumi, G ;
Molnar, F ;
Falotico, R .
NEW ENGLAND JOURNAL OF MEDICINE, 2002, 346 (23) :1773-1780