Assessment of Hygienic Quality of Surfaces in Retail Food Service Establishments Based on Microbial Counts and Real-Time Detection of ATP

被引:50
作者
Cunningham, Annette E. [1 ,2 ]
Rajagopal, Raj [3 ]
Lauer, Jim [1 ,2 ]
Allwood, Paul [1 ,2 ]
机构
[1] Univ Minnesota, Dept Environm Hlth & Safety, Minneapolis, MN 55414 USA
[2] Univ Minnesota, Sch Publ Hlth, Minneapolis, MN 55414 USA
[3] 3M Corp Headquarters, Ctr 3M, St Paul, MN 55144 USA
关键词
CUTTING BOARDS; CLEANING REGIMES; BIOLUMINESCENCE; INDUSTRY; STANDARDS; HOSPITALS; CONTAMINATION; CLEANLINESS; SAFETY;
D O I
10.4315/0362-028X.JFP-10-395
中图分类号
Q81 [生物工程学(生物技术)]; Q93 [微生物学];
学科分类号
071005 ; 0836 ; 090102 ; 100705 ;
摘要
Clean food contact surfaces are important in reducing the likelihood of foodborne disease transmission. The goal of this study was to assess and compare baseline cleanliness of food contact and environmental surfaces in retail food establishments by using ATP bioluminescence (ATP-B), visual assessment, and surface contact plates. Four hundred eighty-nine surface samples were collected from three food service establishments at the University of Minnesota Twin Cities (Minneapolis) and analyzed for either ATP (252) or total aerobic plate count bacteria (237). ATP levels ranged from a minimum of 4 relative light units (RLU; 0.60 log RLU) on a clean slicer to a maximum of 506,618 RLU (5.77 log RLU) on a dirty cutting board. The overall mean was 1,950 RLU (3.29 log RLU). Cutting boards had the highest ATP levels (mean, 5,495 RLU or 3.74 log RLU; median, 6,761 RLU or 3.83 log RLU). Of the 128 samples judged visually clean at the time of sampling, 70.3% failed ATP-B testing. Sixty-one (26%) of the 237 total aerobic plate count samples yielded counts of over 125 CFU/50 cm(2) (failed), and of those that failed, 40% were assessed as visually clean before sampling. The highest average counts in CFU/50 cm(2) were found on slicers (104) and cutting boards (87). The results of this study suggest that the current practice of evaluating food contact surface cleanliness by sight and touch to meet regulatory requirements might be inadequate. ATP-B testing may be an efficient tool to facilitate creation, implementation, and validation of more effective food contact surface cleaning in food establishments.
引用
收藏
页码:686 / 690
页数:5
相关论文
共 27 条
  • [1] [Anonymous], FOOD COD 2009
  • [2] Comparison of results of ATP bioluminescence and traditional hygiene swabbing methods for the determination of surface cleanliness at a hospital kitchen
    Aycicek, H
    Oguz, U
    Karci, K
    [J]. INTERNATIONAL JOURNAL OF HYGIENE AND ENVIRONMENTAL HEALTH, 2006, 209 (02) : 203 - 206
  • [3] The safety of wooden cutting boards -: Remobilization of bacteria from pine, beech, and polyethylene
    Boursillon, Dominique
    Riethmueller, Volker
    [J]. BRITISH FOOD JOURNAL, 2007, 109 (4-5): : 315 - 322
  • [4] Monitoring the Effectiveness of Hospital Cleaning Practices by Use of an Adenosine Triphosphate Bioluminescence Assay
    Boyce, John M.
    Havill, Nancy L.
    Dumigan, Diane G.
    Golebiewski, Michael
    Balogun, Ola
    Rizvani, Ramo
    [J]. INFECTION CONTROL AND HOSPITAL EPIDEMIOLOGY, 2009, 30 (07) : 678 - 684
  • [5] Buchalew J.J., 1996, Foodservice Research International, V9, P25
  • [6] Cliver DO, 2006, J AOAC INT, V89, P538
  • [7] Persistence of Campylobacter jejuni on surfaces in a processing environment and on cutting boards
    Cools, I.
    Uyttendaele, M.
    Cerpentier, J.
    D'Haese, E.
    Nelis, H. J.
    Debevere, J.
    [J]. LETTERS IN APPLIED MICROBIOLOGY, 2005, 40 (06) : 418 - 423
  • [8] Monitoring the effectiveness of cleaning in four British hospitals
    Cooper, Rose A.
    Griffith, Chris J.
    Malik, Rifhat E.
    Obee, Peter
    Looker, Nick
    [J]. AMERICAN JOURNAL OF INFECTION CONTROL, 2007, 35 (05) : 338 - 341
  • [9] How do we assess hospital cleaning? A proposal for microbiological standards for surface hygiene in hospitals
    Dancer, SJ
    [J]. JOURNAL OF HOSPITAL INFECTION, 2004, 56 (01) : 10 - 15
  • [10] Davidson CA, 1999, LUMINESCENCE, V14, P33, DOI 10.1002/(SICI)1522-7243(199901/02)14:1<33::AID-BIO514>3.0.CO