Development and validation of an automated method for the liquid chromatographic determination of sotalol in plasma using dialysis and trace enrichment on a cation-exchange pre-column as on-line sample preparation

被引:25
作者
Chiap, P
Ceccato, A
Buraglia, BM
Boulanger, B
Hubert, P
Crommen, J
机构
[1] Univ Liege, CHU, Inst Pharm, Dept Pharmaceut Analyt Chem, B-4000 Liege 1, Belgium
[2] Lilly Dev Ctr, Dept Stat, B-1348 Mt St Guibert, Belgium
关键词
sotalol; atenolol; plasma; liquid chromatography; sample preparation; dialysis; validation;
D O I
10.1016/S0731-7085(00)00547-1
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A fully automated method for the determination of sotalol in human plasma was developed. involving dialysis through a cellulose acetate membrane, clean-up and enrichment of the dialysate on a strong cation-exchange pre-column and subsequent liquid chromatographic (LC) analysis with UV detection. All sample handling operations were carried out by means of an ASTED system. Before starting dialysis, the trace enrichment column (TEC) was conditioned. The plasma sample, to which the internal standard (atenolol) was automatically added, was then loaded in the donor channel and was kept static while the dialysis liquid, consisting of 0.017 M acetic acid, was passed through the acceptor channel in successive pulses. After each pulse, the dialysate was dispensed onto the TEC. When dialysis was discontinued, the analytes were eluted from the TEC by the LC mobile phase by rotation of a switching valve and transferred to the analytical column packed with octyl silica. The LC mobile phase was a mixture of methanol and pH 7.0 phosphate buffer containing 1-octanesulfonate at a concentration of 7.5 x 10(-4) M (19:81; v/v). The UV detection was performed at 230 nm. The influence of several parameters of the dialysis and trace enrichment processes on analyte recovery and method selectivity was investigated. The method was then validated. The moan absolute recovery for sotalol was about 60%. The limit of quantitation was 25 ng/ml and R.S.D. for repeatability and intermediate precision obtained at a concentration level of 50 ng/ml were 4.3 and 5.8%, respectively. (C) 2001 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:801 / 814
页数:14
相关论文
共 40 条
[1]   AUTOMATED-ANALYSIS OF OXOLINIC ACID AND FLUMEQUINE IN SALMON WHOLE-BLOOD AND PLASMA USING DIALYSIS COMBINED WITH TRACE ENRICHMENT AS ONLINE SAMPLE PREPARATION FOR HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY [J].
AGASOSTER, T ;
RASMUSSEN, KE .
JOURNAL OF CHROMATOGRAPHY-BIOMEDICAL APPLICATIONS, 1991, 564 (01) :171-179
[2]   FULLY AUTOMATED HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHIC ANALYSIS OF WHOLE-BLOOD AND PLASMA SAMPLES USING ONLINE DIALYSIS AS SAMPLE PREPARATION - DETERMINATION OF OXYTETRACYCLINE IN BOVINE AND SALMON WHOLE-BLOOD AND PLASMA [J].
AGASOSTER, T ;
RASMUSSEN, KE .
JOURNAL OF CHROMATOGRAPHY-BIOMEDICAL APPLICATIONS, 1991, 570 (01) :99-107
[3]   AUTOMATED HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY OF IOPENTOL IN HUMAN PLASMA AND WHOLE-BLOOD USING ONLINE DIALYSIS AS SAMPLE PREPARATION [J].
ANDRESEN, AT ;
JACOBSEN, PB ;
RASMUSSEN, KE .
JOURNAL OF CHROMATOGRAPHY-BIOMEDICAL APPLICATIONS, 1992, 575 (01) :93-99
[4]   ONLINE DIALYSIS AND WEAK CATION-EXCHANGE ENRICHMENT OF DIALYSATE - AUTOMATED HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY OF PHOLCODINE IN HUMAN PLASMA AND WHOLE-BLOOD [J].
ANDRESEN, AT ;
KROGH, M ;
RASMUSSEN, KE .
JOURNAL OF CHROMATOGRAPHY-BIOMEDICAL APPLICATIONS, 1992, 582 (1-2) :123-130
[5]   LIQUID-CHROMATOGRAPHIC DETERMINATION OF SOTALOL IN PLASMA AND URINE EMPLOYING SOLID-PHASE EXTRACTION AND FLUORESCENCE DETECTION [J].
BARTEK, MJ ;
VEKSHTEYN, M ;
BOARMAN, MP ;
GALLO, DG .
JOURNAL OF CHROMATOGRAPHY-BIOMEDICAL APPLICATIONS, 1987, 421 (02) :309-318
[6]  
BOUGATY J, 1991, J CHROMATOGR, V565, P523
[7]   Automated determination of verapamil and norverapamil in human plasma with on-line coupling of dialysis to high-performance liquid chromatography and fluorometric detection [J].
Ceccato, A ;
Chiap, P ;
Hubert, P ;
Toussaint, B ;
Crommen, J .
JOURNAL OF CHROMATOGRAPHY A, 1996, 750 (1-2) :351-360
[8]  
CHAPUZET E, 1998, STP PHARM PRATIQUES, V8, P81
[9]  
Chapuzet E., 1997, STP Pharma Pratiques, V7, P169
[10]   Automated liquid chromatographic determination of atenolol in plasma using dialysis and trace enrichment on a cation-exchange precolumn for sample handling [J].
Chiap, P ;
Buraglia, BM ;
Ceccato, A ;
Hubert, P ;
Crommen, J .
JOURNAL OF CHROMATOGRAPHY B, 2000, 739 (01) :205-217