Microfluidic biochip for chemiluminescent detection of allergen-specific antibodies

被引:75
作者
Heyries, Kevin A. [1 ]
Loughran, Michael G. [2 ]
Hoffmann, Daniel [2 ]
Homsy, Alexandra [2 ]
Blum, Loiec J. [1 ]
Marquette, Christophe A. [1 ]
机构
[1] Univ Lyon 1, CNRS, ICBMS 5246, Lab Genie Enzymat & Biomol, F-69622 Villeurbanne, France
[2] Lee Malting, Tyndall Natl Inst, Cork, Ireland
关键词
chemiluminescence; protein microarray; PDMS; microfluidic;
D O I
10.1016/j.bios.2008.02.025
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
Protein microarrays for allergen-specific antibodies detection were integrated in microfluidic chips, with imaging chemiluminescence as the analytical technique. This paper demonstrates the feasibility of miniaturized chemiluminescent ELISA by presenting rapid, reproducible and sensitive detection of protein antibodies using microfluidics. Three different proteins, beta-lactoglobulin, peanut lectin and human IgG were immobilized via a "macro-molecules to polydimethylsiloxane elastomer (PDMS) transfer" protocol and used as capturing agent for the detection of specific antibodies. A convenient and reversible procedure was used to bond the PDMS microarray substrate to complimentary SU-8/glass microfluidic reaction chambers. The hydrodynamic behaviours of the three proteins interactions within the micro-chambers were investigated to select the most efficient flowing parameters (come to terms with the assay time and performances). The use of optimized conditions led to the concomitant detection of three specific antibodies at pM level in 300 mu L and using 6 min sample incubation time. Finally, sera from allergic patients were assayed using the microfluidic device modified with apple hazelnut and pollen allergen. The results obtained compared favourably with those obtained with the classical Pharmacia CAP system. (c) 2008 Elsevier B.V. All rights reserved.
引用
收藏
页码:1812 / 1818
页数:7
相关论文
共 49 条
[11]   Target delivery in a microfluidic immunosensor [J].
Golden, Joel P. ;
Floyd-Smith, Tamara M. ;
Mott, David R. ;
Ligler, Frances S. .
BIOSENSORS & BIOELECTRONICS, 2007, 22 (11) :2763-2767
[12]   Electrochemical microfluidic biosensor for the detection of nucleic acid sequences [J].
Goral, VN ;
Zaytseva, NV ;
Baeumner, AJ .
LAB ON A CHIP, 2006, 6 (03) :414-421
[13]   Straightforward protein immobilization on Sylgard 184 PDMS microarray surface [J].
Heyries, Kevin A. ;
Marquette, Christophe A. ;
Blum, Loic J. .
LANGMUIR, 2007, 23 (08) :4523-4527
[14]   Surface modification of poly(dimethylsiloxane) microfluidic devices by ultraviolet polymer grafting [J].
Hu, SW ;
Ren, XQ ;
Bachman, M ;
Sims, CE ;
Li, GP ;
Allbritton, N .
ANALYTICAL CHEMISTRY, 2002, 74 (16) :4117-4123
[15]   PHOTON-CORRELATION SPECTROSCOPY OF HUMAN-IGG [J].
JOSSANG, T ;
FEDER, J ;
ROSENQVIST, E .
JOURNAL OF PROTEIN CHEMISTRY, 1988, 7 (02) :165-171
[16]   Kinetics of antigen binding to antibody microspots:: Strong limitation by mass transport to the surface [J].
Kusnezow, W ;
Syagailo, YV ;
Rüffer, S ;
Klenin, K ;
Sebald, W ;
Hoheisel, JD ;
Gauer, C ;
Goychuk, I .
PROTEOMICS, 2006, 6 (03) :794-803
[17]   Hazelnut (Corylus avellana) vicilin Cor a 11:: molecular characterization of a glycoprotein and its allergenic activity [J].
Lauer, I ;
Foetisch, K ;
Kolarich, D ;
Ballmer-Weber, BK ;
Conti, A ;
Altmann, F ;
Vieths, S ;
Scheurer, S .
BIOCHEMICAL JOURNAL, 2004, 383 :327-334
[18]   Surface biopassivation of replicated poly(dimethylsiloxane) microfluidic channels and application to heterogeneous immunoreaction with on-chip fluorescence detection [J].
Linder, V ;
Verpoorte, E ;
Thormann, W ;
de Rooij, NF ;
Sigrist, M .
ANALYTICAL CHEMISTRY, 2001, 73 (17) :4181-4189
[19]   The mechanical properties of the rubber elastic polymer polydimethylsiloxane for sensor applications [J].
Lotters, JC ;
Olthuis, W ;
Veltink, PH ;
Bergveld, P .
JOURNAL OF MICROMECHANICS AND MICROENGINEERING, 1997, 7 (03) :145-147
[20]   PDMS microfludic device for optical detection of protein immunoassay using gold nanoparticles [J].
Luo, CX ;
Fu, Q ;
Li, H ;
Xu, LP ;
Sun, MH ;
Ouyang, Q ;
Chen, Y ;
Ji, H .
LAB ON A CHIP, 2005, 5 (07) :726-729