Pace-termination and pacing for prevention of atrial tachyarrhythmias:: Results from a multicenter study with an implantable device for atrial therapy

被引:114
作者
Israel, CW
Hügl, B
Unterberg, C
Lawo, T
Kennis, I
Hettrick, D
Hohnloser, SH
机构
[1] Goethe Univ Frankfurt, Dept Med, Div Cardiol, D-60590 Frankfurt, Germany
[2] Herz Zentrum, Leipzig, Germany
[3] Univ Gottingen Kliniken, Gottingen, Germany
[4] Ruhr Univ Bochum, Dept Cardiol, Bergmannsheil, D-4630 Bochum, Germany
[5] Medtronic Inc, Minneapolis, MN USA
关键词
atrial fibrillation; atrial flutter; antitachycardia pacing; overdrive pacing; dual-chamber pacing; pacemaker algorithm; pacemaker diagnostics;
D O I
10.1046/j.1540-8167.2001.01121.x
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Pacing for Treatment of Atrial Tachyarrhythmias. Introduction: Patients with bradycardia requiring permanent pacing frequently suffer from additional atrial tachyarrhythmias (ATs). This study evaluated the safety and efficacy of atrial antitachycardia pacing (ATP) and the performance of pacing for AT prevention implemented into a new pacemaker. Methods and Results: In patients with conventional indications for permanent pacing, an investigational DDDRP pacemaker (Medtronic AT500, model 7253) was implanted. The primary study objectives were to determine the safety of overall device functioning and its efficacy in terminating spontaneous AT. A secondary endpoint was to determine the reliability of AT detection. Pacemaker memory functions were used to analyze the impact of dedicated pacing algorithms on AT prevention. In 33 European and Canadian centers, 325 patients were enrolled (mean follow-up 2.3 +/-1.3 months). Complication-free survival at 3 months was 88%. In 2,145 episodes stored with atrial electrograms, AT detection was confirmed in 97%. The algorithm for continuous overdrive pacing increased the percentage of atrial pacing to 97%. After ATP activation, 16,683 of 52,468 AT episodes were treated (120 patients). Of these, 8,903 episodes (53%) were terminated successfully by ATP. No proarrhythmic effect of preventive pacing or atrial ATP was observed. Preventive pacing algorithms increased the median percentage of atrial pacing from 62% to 97%. However, the number of AT/AF (atrial fibrillation) episodes (4.1 vs 4.1 per patient per day) and the time in AT/AF (13.7% vs 12.8%) was not significantly different before and after activation of preventive pacing. Conclusion: DDDRP pacing with a new system for AT therapy was safe and associated with successful pace-termination of AT in 53% of episodes. Preventive pacing and atrial ATP algorithms represent two new functions that can be implemented safely into pacemaker systems for nonpharmacologic treatment of ATs in patients requiring pacemaker therapy.
引用
收藏
页码:1121 / 1128
页数:8
相关论文
共 39 条
[11]   Prevention of atrial arrhythmias during DDD pacing by atrial overdrive [J].
Garrigue, S ;
Barold, SS ;
Cazeau, S ;
Gencel, L ;
Jais, P ;
Haissaguerre, M ;
Clémenty, J .
PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 1998, 21 (09) :1751-1759
[12]   Atrial pacing periablation for prevention of paroxysmal atrial fibrillation [J].
Gillis, AM ;
Wyse, DG ;
Connolly, SJ ;
Dubuc, M ;
Philippon, F ;
Yee, R ;
Lacombe, P ;
Rose, MS ;
Kerr, CD .
CIRCULATION, 1999, 99 (19) :2553-2558
[13]   Atrial pacing for the prevention of atrial fibrillation after cardiovascular surgery [J].
Greenberg, MD ;
Katz, NM ;
Iuliano, S ;
Tempesta, BJ ;
Solomon, AJ .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2000, 35 (06) :1416-1422
[14]   ACC/AHA Guidelines for Implantation of Cardiac Pacemakers and Antiarrhythmia Devices: Executive summary - A report of the American College of Cardiology American Heart Association Task Force on Practice Guidelines (Committee on Pacemaker Implantation) [J].
Gregoratos, G ;
Cheitlin, MD ;
Conill, A ;
Epstein, AE ;
Fellows, C ;
Ferguson, TB ;
Freedman, RA ;
Hlatky, MA ;
Naccarelli, GV ;
Saksena, S ;
Schlant, RC ;
Silka, MJ .
CIRCULATION, 1998, 97 (13) :1325-1335
[15]   Results from the use of a preshaped lead for single-pass VDD/DDD stimulation [J].
Israel, CW ;
Kruse, IM ;
Van Mechelen, R ;
Kroes, G ;
Heynen, H ;
Lokhoff, N .
PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 1999, 22 (09) :1314-1320
[16]   Conflicting issues in permanent right atrial lead positioning [J].
Israel, CW .
PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 2000, 23 (11) :1581-1584
[17]   Clinical experience with implantable atrial and combined atrioventricular defibrillators [J].
Jung, W ;
Wolpert, C ;
Esmailzadeh, B ;
Spehl, S ;
Herwig, S ;
Schumacher, B ;
Lewalter, T ;
Omran, H ;
Schimpf, R ;
Vahlhaus, C ;
Welz, A ;
Lüderitz, B .
JOURNAL OF INTERVENTIONAL CARDIAC ELECTROPHYSIOLOGY, 2000, 4 (Suppl 1) :185-195
[18]   EPIDEMIOLOGIC FEATURES OF CHRONIC ATRIAL-FIBRILLATION - THE FRAMINGHAM-STUDY [J].
KANNEL, WB ;
ABBOTT, RD ;
SAVAGE, DD ;
MCNAMARA, PM .
NEW ENGLAND JOURNAL OF MEDICINE, 1982, 306 (17) :1018-1022
[19]   CLINICAL UTILITY AND THE PREDICTORS OF OUTCOME OF OVERDRIVE TRANSESOPHAGEAL ATRIAL-PACING IN THE TREATMENT OF ATRIAL-FLUTTER [J].
KANTHARIA, BK ;
MOOKHERJEE, S .
AMERICAN JOURNAL OF CARDIOLOGY, 1995, 76 (03) :144-147
[20]   REGIONAL ENTRAINMENT OF ATRIAL-FIBRILLATION STUDIED BY HIGH-RESOLUTION MAPPING IN OPEN-CHEST DOGS [J].
KIRCHHOF, C ;
CHORRO, F ;
SCHEFFER, GJ ;
BRUGADA, J ;
KONINGS, K ;
ZETALAKI, Z ;
ALLESSIE, M .
CIRCULATION, 1993, 88 (02) :736-749