Influence of the humidification device during acute respiratory distress syndrome

被引:40
作者
Prat, G [1 ]
Renault, A [1 ]
Tonnelier, JM [1 ]
Goetghebeur, D [1 ]
Oger, E [1 ]
Boles, JM [1 ]
L'Her, E [1 ]
机构
[1] CHU Cavale Blanche, F-29609 Brest, France
关键词
permissive hypercapnia; acute respiratory distress syndrome; mechanical ventilation; airway dead space; humidification systems; heat and moisture exchangers;
D O I
10.1007/s00134-003-1926-5
中图分类号
R4 [临床医学];
学科分类号
1002 ; 100602 ;
摘要
Objective. To evaluate the effects of the humidification device on respiratory, hemodynamic and gas exchange parameters in acute respiratory distress syndrome (ARDS) patients. Design. A prospective open study. Setting. A medical intensive care unit of a university hospital. Patients. Acute respiratory distress syndrome patients, with hypercapnia (PaCO2>60 mmHg). Intervention. A progressive reduction of the humidification system dead space (DSh). The following five conditions were tested sequentially: (1) heat and moisture exchanger (internal volume=95 ml) with a tracheal closed-suction system (internal volume=25 ml; total DSh=120 ml), (2) heat and moisture exchanger (internal volume=45 ml) with the closed-suction system (DSh=70 ml), (3) heat and moisture exchanger (internal volume=25 ml) with the closed-suction system (DSh=50 ml), (4) heated humidifier with the closed-suction system (DSh=25 ml) and (5) heated humidifier alone (DSh=0 ml). Recordings were performed at baseline and every 30 min after each artificial dead-space reduction. All ventilatory settings remained constant during the measurement periods. Results. Ten ARDS patients were included. A significant PaCO2 decrease was observed at each humidification system dead-space reduction, compared to baseline: PaCO2 =80.3+/-20 mmHg at DSh(120) compared to PaCO2 =63.6+/-13 mmHg at DSh(0) (p<0.05). No changes were observed for hemodynamic and ventilatory parameters between the different humidification devices. Conclusion. Artificial airway dead-space reduction allows a significant PaCO2 reduction. Independently of any respiratory mechanical changes, this very simple maneuver may be of importance when low tidal volume ventilation is used in ARDS patients, and when PaCO2 lowering is warranted.
引用
收藏
页码:2211 / 2215
页数:5
相关论文
共 23 条
[1]  
*AC RESP DISTR SYN, 2000, NEW ENGL J MED, V342, P1301, DOI DOI 10.1056/NEJM200005043421801
[2]   THE AMERICAN-EUROPEAN CONSENSUS CONFERENCE ON ARDS - DEFINITIONS, MECHANISMS, RELEVANT OUTCOMES, AND CLINICAL-TRIAL COORDINATION [J].
BERNARD, GR ;
ARTIGAS, A ;
BRIGHAM, KL ;
CARLET, J ;
FALKE, K ;
HUDSON, L ;
LAMY, M ;
LEGALL, JR ;
MORRIS, A ;
SPRAGG, R ;
COCHIN, B ;
LANKEN, PN ;
LEEPER, KV ;
MARINI, J ;
MURRAY, JF ;
OPPENHEIMER, L ;
PESENTI, A ;
REID, L ;
RINALDO, J ;
VILLAR, J ;
VANASBECK, BS ;
DHAINAUT, JF ;
MANCEBO, J ;
MATTHAY, M ;
MEYRICK, B ;
PAYEN, D ;
PERRET, C ;
FOWLER, AA ;
SCHALLER, MD ;
HUDSON, LD ;
HYERS, T ;
KNAUS, W ;
MATTHAY, R ;
PINSKY, M ;
BONE, RC ;
BOSKEN, C ;
JOHANSON, WG ;
LEWANDOWSKI, K ;
REPINE, J ;
RODRIGUEZROISIN, R ;
ROUSSOS, C ;
ANTONELLI, MA ;
BELOUCIF, S ;
BIHARI, D ;
BURCHARDI, H ;
LEMAIRE, F ;
MONTRAVERS, P ;
PETTY, TL ;
ROBOTHAM, J ;
ZAPOL, W .
AMERICAN JOURNAL OF RESPIRATORY AND CRITICAL CARE MEDICINE, 1994, 149 (03) :818-824
[3]  
Campbell R S, 2000, Respir Care, V45, P306
[4]   HIGH INFLATION PRESSURE PULMONARY-EDEMA - RESPECTIVE EFFECTS OF HIGH AIRWAY PRESSURE, HIGH TIDAL VOLUME, AND POSITIVE END-EXPIRATORY PRESSURE [J].
DREYFUSS, D ;
SOLER, P ;
BASSET, G ;
SAUMON, G .
AMERICAN REVIEW OF RESPIRATORY DISEASE, 1988, 137 (05) :1159-1164
[5]   Safety of combined heat and moisture exchanger filters in long-term mechanical ventilation [J].
Hurni, JM ;
Feihl, F ;
Lazor, R ;
Leuenberger, P ;
Perret, C .
CHEST, 1997, 111 (03) :686-691
[6]   Unfavorable mechanical effects of heat and moisture exchangers in ventilated patients [J].
Iotti, GA ;
Olivei, MC ;
Palo, A ;
Galbusera, C ;
Veronesi, R ;
Comelli, A ;
Brunner, JX ;
Braschi, A .
INTENSIVE CARE MEDICINE, 1997, 23 (04) :399-405
[7]   Permissive hypercapnia with and without expiratory washout in patients with severe acute respiratory distress syndrome [J].
Kalfon, P ;
Rao, GSU ;
Gallart, L ;
Puybasset, L ;
Coriat, P ;
Rouby, JJ .
ANESTHESIOLOGY, 1997, 87 (01) :6-17
[8]   Comparison of the effects of heat and moisture exchangers and heated humidifiers on ventilation and gas exchange during weaning trials from mechanical ventilation [J].
LeBourdelles, G ;
Mier, L ;
Fiquet, B ;
Djedaini, K ;
Saumon, G ;
Coste, F ;
Dreyfuss, D .
CHEST, 1996, 110 (05) :1294-1298
[9]   The logistic organ dysfunction system - A new way to assess organ dysfunction in the intensive care unit [J].
LeGall, JR ;
Klar, J ;
Lemeshow, S ;
Saulnier, F ;
Alberti, C ;
Artigas, A ;
Teres, D .
JAMA-JOURNAL OF THE AMERICAN MEDICAL ASSOCIATION, 1996, 276 (10) :802-810
[10]   A NEW SIMPLIFIED ACUTE PHYSIOLOGY SCORE (SAPS-II) BASED ON A EUROPEAN NORTH-AMERICAN MULTICENTER STUDY [J].
LEGALL, JR ;
LEMESHOW, S ;
SAULNIER, F .
JAMA-JOURNAL OF THE AMERICAN MEDICAL ASSOCIATION, 1993, 270 (24) :2957-2963