ComparisOn of neointimal coVerage betwEen zotaRolimus-eluting stent and everolimus-eluting stent using Optical Coherence Tomography (COVER OCT)

被引:42
作者
Kim, Jung-Sun [1 ,2 ]
Kim, Byeong-Kuk [1 ,2 ]
Jang, Ik-Kyung [3 ]
Shin, Dong-Ho [1 ,2 ]
Ko, Young-Guk [1 ,2 ]
Choi, Donghoon [1 ,2 ]
Hong, Myeong-Ki [1 ,2 ]
Cho, Yun-Kyeong [4 ]
Nam, Chang-Wook [4 ]
Hur, Seung-Ho [4 ]
Choi, Jin-Ho [5 ]
Song, Young Bin [5 ]
Hahn, Joo Yong [5 ]
Choi, Seung Hyuk [5 ]
Gwon, Hyeon Cheol [5 ]
Jang, Yangsoo [1 ]
机构
[1] Yonsei Univ, Div Cardiol, Yonsei Cardiovasc Ctr, Coll Med, Seoul 120752, South Korea
[2] Yonsei Univ, Div Cardiol, Severance Biomed Sci Inst, Seoul 120752, South Korea
[3] Harvard Univ, Massachusetts Gen Hosp, Sch Med, Div Cardiol, Boston, MA USA
[4] Keimyung Univ, Dongsan Med Ctr, Taegu, South Korea
[5] Sungkyunkwan Univ, Div Cardiol, Samsung Med Ctr, Coll Med, Seoul, South Korea
关键词
CORONARY-ARTERY-DISEASE; VASCULAR-RESPONSE; STRUT COVERAGE; DRUG-RELEASE; BARE-METAL; IMPLANTATION; RESOLUTE; SYSTEM; TRIAL; THROMBOSIS;
D O I
10.1016/j.ahj.2011.10.016
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background Data on strut surface coverage of second-generation drug-eluting stents (DES) are limited. We investigated stent strut coverage of resolute zotarolimus-eluting stent (ZES-R) or everolimus-eluting stent (EES) at 9 months after implantation using optical coherence tomography (OCT). Methods ComparisOn of neointimal coVerage betwEen zotaRolimus-eluting stent and everolimus-eluting stent using Optical Coherence Tomography (COVER OCT) is a prospective, randomized, multicenter trial comparing ZES-R to EES using OCT at 9 months after stent implantation. The primary end point was the rate of stent strut coverage at 9 months. Results A total of 51 patients were randomized to receive either ZES-R (ZES-R group) or EES (EES group), and 47 stents (24 ZES-R and 23 EES) in 44 of 51 patients were evaluated by OCT both immediately after stent implantation and at 9 months. The neointimal thickness was not significantly different between the 2 groups at 9 months (ZES-R vs EES: 139 +/- 58 vs 124 +/- 42 mu m, P = .31). The mean percentages of uncovered stent struts were 3.3% for ZES-R versus 3.4% for EES at 9 months (P = .51). The proportions of malapposed struts immediately after stent implantation (P = .89) and at 9-month follow-up (P = .34) were 0.8% and 0.7% for ZES-R versus 1.0% and 0.1% for EES, respectively. Thrombi were documented in 1 stent (1 [4.2%] in ZES-R vs 0 [0%] in EES). Conclusion According to the sequential OCT evaluation, ZES-R and EES showed comparable neointimal thickness and the rate of uncovered stent strut at 9 months after stent implantation. (Am Heart J 2012; 163:601-7.)
引用
收藏
页码:601 / 607
页数:7
相关论文
共 21 条
[21]   Clinical Evaluation of the Resolute Zotarolimus-Eluting Coronary Stent System in the Treatment of De Novo Lesions in Native Coronary Arteries The RESOLUTE US Clinical Trial [J].
Yeung, Alan C. ;
Leon, Martin B. ;
Jain, Ash ;
Tolleson, Thaddeus R. ;
Spriggs, Douglas J. ;
Laurin, Brent T. Mc ;
Popma, Jeffrey J. ;
Fitzgerald, Peter J. ;
Cutlip, Donald E. ;
Massaro, Joseph M. ;
Mauri, Laura .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2011, 57 (17) :1778-1783