共 21 条
ComparisOn of neointimal coVerage betwEen zotaRolimus-eluting stent and everolimus-eluting stent using Optical Coherence Tomography (COVER OCT)
被引:42
作者:
Kim, Jung-Sun
[1
,2
]
Kim, Byeong-Kuk
[1
,2
]
Jang, Ik-Kyung
[3
]
Shin, Dong-Ho
[1
,2
]
Ko, Young-Guk
[1
,2
]
Choi, Donghoon
[1
,2
]
Hong, Myeong-Ki
[1
,2
]
Cho, Yun-Kyeong
[4
]
Nam, Chang-Wook
[4
]
Hur, Seung-Ho
[4
]
Choi, Jin-Ho
[5
]
Song, Young Bin
[5
]
Hahn, Joo Yong
[5
]
Choi, Seung Hyuk
[5
]
Gwon, Hyeon Cheol
[5
]
Jang, Yangsoo
[1
]
机构:
[1] Yonsei Univ, Div Cardiol, Yonsei Cardiovasc Ctr, Coll Med, Seoul 120752, South Korea
[2] Yonsei Univ, Div Cardiol, Severance Biomed Sci Inst, Seoul 120752, South Korea
[3] Harvard Univ, Massachusetts Gen Hosp, Sch Med, Div Cardiol, Boston, MA USA
[4] Keimyung Univ, Dongsan Med Ctr, Taegu, South Korea
[5] Sungkyunkwan Univ, Div Cardiol, Samsung Med Ctr, Coll Med, Seoul, South Korea
关键词:
CORONARY-ARTERY-DISEASE;
VASCULAR-RESPONSE;
STRUT COVERAGE;
DRUG-RELEASE;
BARE-METAL;
IMPLANTATION;
RESOLUTE;
SYSTEM;
TRIAL;
THROMBOSIS;
D O I:
10.1016/j.ahj.2011.10.016
中图分类号:
R5 [内科学];
学科分类号:
1002 ;
100201 ;
摘要:
Background Data on strut surface coverage of second-generation drug-eluting stents (DES) are limited. We investigated stent strut coverage of resolute zotarolimus-eluting stent (ZES-R) or everolimus-eluting stent (EES) at 9 months after implantation using optical coherence tomography (OCT). Methods ComparisOn of neointimal coVerage betwEen zotaRolimus-eluting stent and everolimus-eluting stent using Optical Coherence Tomography (COVER OCT) is a prospective, randomized, multicenter trial comparing ZES-R to EES using OCT at 9 months after stent implantation. The primary end point was the rate of stent strut coverage at 9 months. Results A total of 51 patients were randomized to receive either ZES-R (ZES-R group) or EES (EES group), and 47 stents (24 ZES-R and 23 EES) in 44 of 51 patients were evaluated by OCT both immediately after stent implantation and at 9 months. The neointimal thickness was not significantly different between the 2 groups at 9 months (ZES-R vs EES: 139 +/- 58 vs 124 +/- 42 mu m, P = .31). The mean percentages of uncovered stent struts were 3.3% for ZES-R versus 3.4% for EES at 9 months (P = .51). The proportions of malapposed struts immediately after stent implantation (P = .89) and at 9-month follow-up (P = .34) were 0.8% and 0.7% for ZES-R versus 1.0% and 0.1% for EES, respectively. Thrombi were documented in 1 stent (1 [4.2%] in ZES-R vs 0 [0%] in EES). Conclusion According to the sequential OCT evaluation, ZES-R and EES showed comparable neointimal thickness and the rate of uncovered stent strut at 9 months after stent implantation. (Am Heart J 2012; 163:601-7.)
引用
收藏
页码:601 / 607
页数:7
相关论文