Optimal Projection Estimation for Transcatheter Aortic Valve Implantation Based on Contrast-Aortography: Validation of a Prototype Software

被引:48
作者
Tzikas, Apostolos [1 ]
Schultz, Carl [1 ]
Van Mieghem, Nicolas M. [1 ]
de Jaegere, Peter P. T. [1 ]
Serruys, Patrick W. [1 ]
机构
[1] Erasmus MC, Dept Cardiol, Thoraxctr, NL-3015 CE Rotterdam, Netherlands
关键词
aortic stenosis; multi-slice computed tomography; C-THV; MULTISLICE COMPUTED-TOMOGRAPHY; REPLACEMENT; STENOSIS; ROOT;
D O I
10.1002/ccd.22641
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
We investigate the accuracy of a new software system (C-THV, Paieon) designed to calculate the optimal projection (OP) view for transcatheter aortic valve implantation (TAVI) based on two aortograms, and its agreement with the operator's choice. An optimal fluoroscopic working view projection with all three aortic cusps depicted in one line, is crucial during TAVI. In our institution selection of the OP is based on multislice computed tomography (MSCT). Seventy-three consecutive patients referred for TAVI were divided into two groups. For the first group (53 patients, retrospective cohort) we compared the OP views estimated by C-THV with the ones estimated by MSCT. For the second group (20 patients, prospective cohort), we compared the OP views estimated by C-THV with the operator's choice during TAVI. For the retrospective cohort, the mean absolute difference (mean +/- SD) between C-THV and MSCT was 6.6 +/- 4.9 degrees. In 77% of the cases the mean difference between C-THV and MSCT was <10 degrees. For the prospective cohort, the mean absolute difference (mean +/- SD) between C-THV and the operator's choice was 5.5 +/- 3.4 degrees. A mean difference of <10 degrees was found in 90% of the cases. In this study we found that the C-THV software estimated the OP view for TAVI with good accuracy. The level of agreement between C-THV and either the MSCT or the operator's choice was deemed satisfactory, with the vast majority of observed differences being <10 degrees. (C) 2010 Wiley-Liss, Inc.
引用
收藏
页码:602 / 607
页数:6
相关论文
共 9 条
[1]   Treatment of calcific aortic stenosis with the percutaneous heart valve - Mid-term follow-up from the initial feasibility studies: The French experience [J].
Cribier, A ;
Eltchaninoff, H ;
Tron, C ;
Bauer, F ;
Agatiello, C ;
Nercolini, D ;
Tapiero, S ;
Litzler, PY ;
Bessou, JP ;
Babaliaros, V .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2006, 47 (06) :1214-1223
[2]   Pre-Procedural Imaging of Aortic Root Orientation and Dimensions Comparison Between X-Ray Angiographic Planar Imaging and 3-Dimensional Multidetector Row Computed Tomography [J].
Kurra, Vikram ;
Kapadia, Samir R. ;
Tuzcu, E. Murat ;
Halliburton, Sandra S. ;
Svensson, Lars ;
Roselli, Eric E. ;
Schoenhagen, Paul .
JACC-CARDIOVASCULAR INTERVENTIONS, 2010, 3 (01) :105-113
[3]   Multimodal Assessment of the Aortic Annulus Diameter Implications for Transcatheter Aortic Valve Implantation [J].
Messika-Zeitoun, David ;
Serfaty, Jean-Michel ;
Brochet, Eric ;
Ducrocq, Gregory ;
Lepage, Laurent ;
Detaint, Delphine ;
Hyafil, Fabien ;
Himbert, Dominique ;
Pasi, Nicoletta ;
Laissy, Jean-Pierre ;
Iung, Bernard ;
Vahanian, Alec .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2010, 55 (03) :186-194
[4]  
Piazza Nicolo, 2008, EuroIntervention, V4, P242, DOI 10.4244/EIJV4I2A43
[5]   Three dimensional evaluation of the aortic annulus using multislice computer tomography: are manufacturer's guidelines for sizing for percutaneous aortic valve replacement helpful? [J].
Schultz, Carl J. ;
Moelker, Adriaan ;
Piazza, Nicolo ;
Tzikas, Apostolos ;
Otten, Amber ;
Nuis, Rutger J. ;
Neefjes, Lisan A. ;
van Geuns, Robert J. ;
de Feyter, Pim ;
Krestin, Gabriel ;
Serruys, Patrick W. ;
de Jaegere, Peter P. T. .
EUROPEAN HEART JOURNAL, 2010, 31 (07) :849-856
[6]   Geometry and Degree of Apposition of the CoreValve ReValving System With Multislice Computed Tomography After Implantation in Patients With Aortic Stenosis [J].
Schultz, Carl J. ;
Weustink, Annick ;
Piazza, Nicolo ;
Otten, Amber ;
Mollet, Nico ;
Krestin, Gabriel ;
van Geuns, Robert J. ;
de Feyter, Pim ;
Serruys, Patrick W. J. ;
de Jaegere, Peter .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2009, 54 (10) :911-918
[7]   Noninvasive Evaluation of the Aortic Root With Multislice Computed Tomography Implications for Transcatheter Aortic Valve Replacement [J].
Tops, Laurens F. ;
Wood, David A. ;
Delgado, Victoria ;
Schuijf, Joanne D. ;
Mayo, John R. ;
Pasupati, Sanjeevan ;
Lamers, Frouke P. L. ;
van der Wall, Ernst E. ;
Schalij, Martin J. ;
Webb, John G. ;
Bax, Jeroen J. .
JACC-CARDIOVASCULAR IMAGING, 2008, 1 (03) :321-330
[8]   Percutaneous transarterial aortic valve replacement in selected high-risk patients with aortic stenosis [J].
Webb, John G. ;
Pasupati, Sanjeevan ;
Humphries, Karin ;
Thompson, Christopher ;
Altwegg, Lukas ;
Moss, Robert ;
Sinhal, Ajay ;
Carere, Ronald G. ;
Munt, Brad ;
Ricci, Donald ;
Ye, Jian ;
Cheung, Anson ;
Lichtenstein, Sam V. .
CIRCULATION, 2007, 116 (07) :755-763
[9]   MATHEMATICAL TOOLS FOR SPATIAL COMPUTATIONS WITH BIPLANE ISOCENTRIC X-RAY-EQUIPMENT [J].
WOLLSCHLAGER, H ;
LEE, P ;
ZEIHER, A ;
SOLZBACH, U ;
BONZEL, T ;
JUST, H .
BIOMEDIZINISCHE TECHNIK, 1986, 31 (05) :101-106