Pre-Procedural Imaging of Aortic Root Orientation and Dimensions Comparison Between X-Ray Angiographic Planar Imaging and 3-Dimensional Multidetector Row Computed Tomography

被引:96
作者
Kurra, Vikram [1 ,2 ]
Kapadia, Samir R. [2 ]
Tuzcu, E. Murat [2 ]
Halliburton, Sandra S. [1 ,2 ]
Svensson, Lars [2 ]
Roselli, Eric E. [2 ]
Schoenhagen, Paul [1 ,2 ]
机构
[1] Cleveland Clin, Imaging Inst, Cleveland, OH 44195 USA
[2] Cleveland Clin, Inst Heart & Vasc, Cleveland, OH 44195 USA
关键词
multidetector computed tomography; angiography; transcatheter aortic valve implantation; aortic stenosis; aortic valve; VALVE-REPLACEMENT; STENOSIS; IMPLANTATION;
D O I
10.1016/j.jcin.2009.10.014
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Objectives We sought to examine whether contrast-enhanced multidetector row computed tomography (MDCT) allows prediction of X-ray angiographic planes for the root angiogram in the context of transcatheter aortic valve implantation. Background Understanding of aortic root orientation relative to the body axis is critical for precise positioning of the stent/valve during transcatheter aortic valve implantation. Methods Forty patients with severe aortic stenosis underwent conventional X-ray angiography and contrast-enhanced MDCT of the aortic root. Oblique MDCT images of the aortic root, corresponding to X-ray angiographic left anterior oblique (LA)/right anterior oblique (RAO) projections, were created. The cranial/caudal angulation was compared between angiographic and reformatted MDCT images. In addition, root diameter measurements were compared. Results The cranial angulation in the LAO X-ray angiograms (mean LAO: 39 +/- 8, n = 38) and matched MDCT images were not significantly different (cranial: 25 +/- 7 vs. 23 +/- 8; p = 0.214). There was a small but significant difference between the caudal angulation in the RAO angiogram (mean RAO: 25 +/- 5, n = 40) and matched CT images (caudal: 21 +/- 9 vs. 29 +/- 10; p = 0.002). The annulus diameter in the LAO projection was not significantly different between X-ray angiography and contrast-enhanced MDCT (2.3 +/- 0.3 vs. 2.4 +/- 0.3; p = 0.052), whereas there was a small but significant difference in the annulus diameter in RAO projections between angiography and MDCT (2.4 +/- 0.3 vs. 2.2 +/- 0.3; p = 0.029). Conclusions Pre-procedural contrast-enhanced MDCT imaging of the aortic root allows prediction of X-ray angiographic planes and contributes to planning of the transcatheter aortic valve implantation. (J Am Coll Cardiol Intv 2010;3:105-13) (C) 2010 by the American College of Cardiology Foundation
引用
收藏
页码:105 / 113
页数:9
相关论文
共 15 条
  • [1] Aortic root morphology in patients undergoing percutaneous aortic valve replacement: Evidence of aortic root remodeling
    Akhtar, Mateen
    Tuzcu, E. Murat
    Kapadia, Samir R.
    Svensson, Lars G.
    Greenberg, Roy K.
    Roselli, Eric E.
    Halliburton, Sandra
    Kurra, Vikram
    Schoenhagen, Paul
    Sola, Srikanth
    [J]. JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 2009, 137 (04) : 950 - 956
  • [2] Intravenous contrast material administration at 16-detector row helical CT coronary angiography: Test bolus versus bolus-tracking technique
    Cademartiri, F
    Nieman, K
    van der Lugt, A
    Raaijmakers, RH
    Mollet, N
    Pattynama, PMT
    de Feyter, PJ
    Krestin, GP
    [J]. RADIOLOGY, 2004, 233 (03) : 817 - 823
  • [3] Rotational Flat-Panel Computed Tomography in Diagnostic and Interventional Neuroradiology
    Doerfler, A.
    Struffert, T.
    Engelhorn, T.
    Richter, G.
    [J]. ROFO-FORTSCHRITTE AUF DEM GEBIET DER RONTGENSTRAHLEN UND DER BILDGEBENDEN VERFAHREN, 2008, 180 (10): : 891 - 898
  • [4] Characterization and outcome of patients with severe symptomatic aortic stenosis referred for percutaneous aortic valve replacement
    Kapadia, Samir R.
    Goel, Sachin S.
    Svensson, Lars
    Roselli, Eric
    Savage, Robert M.
    Wallace, Lee
    Sola, Srikanth
    Schoenhagen, Paul
    Shishehbor, Mehdi H.
    Christofferson, Ryan
    Halley, Carmel
    Rodriguez, L. Leonardo
    Stewart, William
    Kalahasti, Vidyasagar
    Tuzcu, E. Murat
    [J]. JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 2009, 137 (06) : 1430 - 1435
  • [5] Imaging of the Coronary Venous System: Validation of Three-Dimensional Rotational Venous Angiography Against Dual-Source Computed Tomography
    Knackstedt, Christian
    Muehlenbruch, Georg
    Mischke, Karl
    Bruners, Philipp
    Schimpf, Thomas
    Frechen, Dirk
    Schummers, Georg
    Mahnken, Andreas H.
    Guenther, Rolf W.
    Kelm, Malte
    Schauerte, Patrick
    [J]. CARDIOVASCULAR AND INTERVENTIONAL RADIOLOGY, 2008, 31 (06) : 1150 - 1158
  • [6] Ex vivo and in vivo coronary ostial locations in humans
    Knight, Joseph
    Kurtcuoglu, Vartan
    Muffly, Karl
    Marshall, William, Jr.
    Stolzmann, Paul
    Desbiolles, Lotus
    Seifert, Burkhardt
    Poulikakos, Dimos
    Alkadhi, Hatem
    [J]. SURGICAL AND RADIOLOGIC ANATOMY, 2009, 31 (08) : 597 - 604
  • [7] Prevalence of significant peripheral artery disease in patients evaluated for percutaneous aortic valve insertion: Preprocedural assessment with multidetector computed tomography
    Kurra, Vikram
    Schoenhagen, Paul
    Roselli, Eric E.
    Kapadia, Samir R.
    Tuzcu, E. Murat
    Greenberg, Roy
    Akhtar, Mateen
    Desai, Milind Y.
    Flamm, Scott D.
    Halliburton, Sandra S.
    Svensson, Lars G.
    Sola, Srikanth
    [J]. JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 2009, 137 (05) : 1258 - 1264
  • [8] Neuroradiologic Applications with Routine C-arm Flat Panel Detector CT: Evaluation of Patient Dose Measurements
    Kyriakou, Y.
    Richter, G.
    Doerfler, A.
    Kalender, W. A.
    [J]. AMERICAN JOURNAL OF NEURORADIOLOGY, 2008, 29 (10) : 1930 - 1936
  • [9] Comprehensive evaluation of preoperative patients with aortic valve stenosis: usefulness of cardiac multidetector computed tomography
    Laissy, Jean-Pierre
    Messika-Zeitoun, David
    Serfaty, Jean-Michel
    Sebban, Vincent
    Schouman-Claeys, Elisabeth
    Lung, Bernard
    Vahanian, Alec
    [J]. HEART, 2007, 93 (09) : 1121 - 1125
  • [10] Three-dimensional left atrial and esophagus reconstruction using cardiac C-arm computed tomography with image integration into fluoroscopic views for ablation of atrial fibrillation: Accuracy of a novel modality in comparison with multislice computed tomography
    Noelker, Georg
    Gutleben, Klaus Juergen
    Marschang, Harald
    Ritscher, Guido
    Asbach, Stefan
    Marrouche, Nassir
    Brachman, Johannes
    Sinha, Anil Martin
    [J]. HEART RHYTHM, 2008, 5 (12) : 1651 - 1657