Transient phenomena in a PEMFC during the start-up of gas feeding observed with a 97-fold segmented cell
被引:54
作者:
Siroma, Zyun
论文数: 0引用数: 0
h-index: 0
机构:
Natl Inst Adv Ind Sci & Technol, Res Inst Ubiquitious Energy Devices, Osaka 5638577, JapanNatl Inst Adv Ind Sci & Technol, Res Inst Ubiquitious Energy Devices, Osaka 5638577, Japan
Siroma, Zyun
[1
]
Fujiwara, Naoko
论文数: 0引用数: 0
h-index: 0
机构:
Natl Inst Adv Ind Sci & Technol, Res Inst Ubiquitious Energy Devices, Osaka 5638577, JapanNatl Inst Adv Ind Sci & Technol, Res Inst Ubiquitious Energy Devices, Osaka 5638577, Japan
Fujiwara, Naoko
[1
]
Loroi, Tsutomu
论文数: 0引用数: 0
h-index: 0
机构:
Natl Inst Adv Ind Sci & Technol, Res Inst Ubiquitious Energy Devices, Osaka 5638577, JapanNatl Inst Adv Ind Sci & Technol, Res Inst Ubiquitious Energy Devices, Osaka 5638577, Japan
Loroi, Tsutomu
[1
]
Yamazaki, Shin-ichi
论文数: 0引用数: 0
h-index: 0
机构:
Natl Inst Adv Ind Sci & Technol, Res Inst Ubiquitious Energy Devices, Osaka 5638577, JapanNatl Inst Adv Ind Sci & Technol, Res Inst Ubiquitious Energy Devices, Osaka 5638577, Japan
Yamazaki, Shin-ichi
[1
]
Senoh, Hiroshi
论文数: 0引用数: 0
h-index: 0
机构:
Natl Inst Adv Ind Sci & Technol, Res Inst Ubiquitious Energy Devices, Osaka 5638577, JapanNatl Inst Adv Ind Sci & Technol, Res Inst Ubiquitious Energy Devices, Osaka 5638577, Japan
Senoh, Hiroshi
[1
]
Yasuda, Kazuaki
论文数: 0引用数: 0
h-index: 0
机构:
Natl Inst Adv Ind Sci & Technol, Res Inst Ubiquitious Energy Devices, Osaka 5638577, JapanNatl Inst Adv Ind Sci & Technol, Res Inst Ubiquitious Energy Devices, Osaka 5638577, Japan
Yasuda, Kazuaki
[1
]
Tanimoto, Kazumi
论文数: 0引用数: 0
h-index: 0
机构:
Natl Inst Adv Ind Sci & Technol, Res Inst Ubiquitious Energy Devices, Osaka 5638577, JapanNatl Inst Adv Ind Sci & Technol, Res Inst Ubiquitious Energy Devices, Osaka 5638577, Japan
Tanimoto, Kazumi
[1
]
机构:
[1] Natl Inst Adv Ind Sci & Technol, Res Inst Ubiquitious Energy Devices, Osaka 5638577, Japan
To measure local phenomena in a PEMFC during a transitional state induced by changing of the feeding gas, a segmented cell was fabricated and the local current and local potential distribution were measured under open-circuit conditions. The anode or cathode was divided into 97 segments of 1.5 mm each. A change in the anode gas from nitrogen or oxygen to hydrogen induced momentary internal currents among the segments. The potential distribution in the electrolyte was observed simultaneously using three quasi-reference electrodes located locally. The results supported the reverse-current decay mechanism, which is known to be a mechanism of cathode degradation. Furthermore, internal currents were observed when the cathode gas was changed from nitrogen to oxygen. While the cathode was not subjected to a harmful potential, a large potential distribution was induced in the anode. (C) 2007 Elsevier B.V. All rights reserved.