Quantitative colorectal cancer perfusion measurement using dynamic contrast-enhanced multidetector-row computed tomography - Effect of acquisition time and implications for protocols

被引:57
作者
Goh, V
Halligan, S
Hugill, JA
Gartner, L
Bartram, CI
机构
[1] St Marks Hosp, Intestinal Imaging Ctr, Harrow HA1 3UJ, Middx, England
[2] Mt Vernon Hosp, Paul Strickland Scanner Ctr, Northwood HA6 2RN, Middx, England
关键词
computed tomography; perfusion study; rectum; neoplasms; colon;
D O I
10.1097/01.rct.0000152847.00257.d7
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Objective: To determine the effect of acquisition time on quantitative colorectal cancer perfusion measurement. Methods: Dynamic contrast-enhanced computed tomography (CT) was performed prospectively in 10 patients with histologically proven colorectal cancer using 4-detector row CT (Lightspeed Plus; GE Healthcare Technologies, Waukesha, WI). Tumor blood flow, blood volume, mean transit time, and permeability were assessed for 3 acquisition times (45, 65, and 130 seconds). Mean values for all 4 perfusion parameters for each acquisition time were compared using the paired t test. Results: Significant differences in permeability values were noted between acquisitions of 45 seconds and 65 and 130 seconds, respectively (P = 0.02, P = 0.007). There was no significant difference for values of blood volume, blood flow, and mean transit time between any of the acquisition times. Conclusions: Scan acquisitions of 45 seconds are too short for reliable permeability measurement in the abdomen. Longer acquisition times are required.
引用
收藏
页码:59 / 63
页数:5
相关论文
共 24 条
[11]   Perfusion CT in patients with advanced bronchial carcinomas:: a novel chance for characterization and treatment monitoring? [J].
Kiessling, F ;
Boese, J ;
Corvinus, C ;
Ederle, JR ;
Zuna, I ;
Schoenberg, SO ;
Brix, G ;
Schmähl, A ;
Tuengerthal, S ;
Herth, F ;
Kauczor, HU ;
Essig, M .
EUROPEAN RADIOLOGY, 2004, 14 (07) :1226-1233
[12]   Tumor angiogenesis: Molecular pathology, therapeutic targeting, and imaging [J].
Li, WW .
ACADEMIC RADIOLOGY, 2000, 7 (10) :800-811
[13]  
Miles K, 1997, FUNCTIONAL COMPUTED
[14]   FUNCTIONAL IMAGING OF CHANGES IN HUMAN INTRARENAL PERFUSION USING QUANTITATIVE DYNAMIC COMPUTED-TOMOGRAPHY [J].
MILES, KA ;
HAYBALL, MP ;
DIXON, AK .
INVESTIGATIVE RADIOLOGY, 1994, 29 (10) :911-914
[15]   CT measurements of capillary permeability within nodal masses: A potential technique for assessing the activity of lymphoma [J].
Miles, KA ;
Kelley, BB .
BRITISH JOURNAL OF RADIOLOGY, 1997, 70 :74-79
[16]   MEASUREMENT OF TISSUE PERFUSION BY DYNAMIC COMPUTED-TOMOGRAPHY [J].
MILES, KA .
BRITISH JOURNAL OF RADIOLOGY, 1991, 64 (761) :409-412
[17]   FUNCTIONAL IMAGES OF HEPATIC PERFUSION OBTAINED WITH DYNAMIC CT [J].
MILES, KA ;
HAYBALL, MP ;
DIXON, AK .
RADIOLOGY, 1993, 188 (02) :405-411
[18]   Perfusion CT for the assessment of tumour vascularity: which protocol? [J].
Miles, KA .
BRITISH JOURNAL OF RADIOLOGY, 2003, 76 :S36-S42
[19]   Perfusion CT: a worthwhile enhancement? [J].
Miles, KA ;
Griffiths, MR .
BRITISH JOURNAL OF RADIOLOGY, 2003, 76 (904) :220-231
[20]   MEASUREMENT OF HUMAN PANCREATIC PERFUSION USING DYNAMIC COMPUTED-TOMOGRAPHY WITH PERFUSION IMAGING [J].
MILES, KA ;
HAYBALL, MP ;
DIXON, AK .
BRITISH JOURNAL OF RADIOLOGY, 1995, 68 (809) :471-475