Noninvasive estimation of transmitral pressure drop across the normal mitral valve in humans: Importance of convective and inertial forces during left ventricular filling

被引:58
作者
Firstenberg, MS
Vandervoort, PM
Greenberg, NL
Smedira, NG
McCarthy, PM
Garcia, MJ
Thomas, JD
机构
[1] Cleveland Clin Fdn, Dept Cardiol, Cardiovasc Imaging Ctr, Cleveland, OH 44195 USA
[2] Cleveland Clin Fdn, Dept Thorac & Cardiovasc Surg, Cleveland, OH 44195 USA
关键词
D O I
10.1016/S0735-1097(00)00963-3
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
OBJECTIVES We hypothesized that color M-mode (CMM) images could be used to solve the Euler equation, yielding regional pressure gradients along the scanline, which could then be integrated to yield the unsteady Bernoulli equation and estimate noninvasively both the convective and inertial components of the transmitral pressure difference. BACKGROUND Pulsed and continuous wave Doppler velocity measurements are routinely used clinically to assess severity of stenotic and regurgitant valves:es. However, only the convective component of the pressure gradient is measured, thereby neglecting the contribution of inertial forces, which may be significant, particularly for nonstenotic valves. Color M-made provides a spatiotemporal representation of flow across the mitral valve. METHODS In eight patients undergoing coronary artery bypass grafting, high-fidelity left atrial and ventricular pressure measurements were obtained synchronously with transmitral CMM;I. digital recordings. The instantaneous diastolic transmitral pressure difference was computed from the M-mode spatiotemporal velocity distribution using the unsteady flow form of the Bernoulli equation and was compared to the catheter measurements. RESULTS From 56 beats in 16 hemodynamic stages, inclusion of the inertial term ([Deltap(l)](max) = 1.78 +/- 1.30 mm Hg) in the noninvasive pressure difference calculation significantly increased the temporal correlation with catheter-based measurement (r = 0.35 r 0.24 vs. 0.81 +/- 0.15, p < 0.0001). It also allowed an accurate approximation of the peak pressure difference ([<Delta>p(C+l)](max) = 0.95 [p(cath)](max) + 0.24, r = 0.96, p < 0.001, error = 0.08 +/- 0.54 mm Hg). CONCLUSIONS Inertial forces are significant components of the maximal pressure drop across the normal mitral valve. These can be accurately estimated noninvasively using CMM recordings of transmitral flow, which should improve the understanding of diastolic filling and function of the heart. (C) 2000 by the American College of Cardiology.
引用
收藏
页码:1942 / 1949
页数:8
相关论文
共 44 条
[31]   ESTIMATION OF REGURGITANT FLOW-VOLUME BASED ON CENTERLINE VELOCITY/DISTANCE PROFILES USING DIGITAL COLOR M-Q DOPPLER - APPLICATION TO ORIFICES OF DIFFERENT SHAPES [J].
SHIOTA, T ;
TEIEN, D ;
DENG, YB ;
GE, SP ;
SHANDAS, R ;
HOLCOMB, S ;
SAHN, DJ .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1994, 24 (02) :440-445
[32]   ERRORS IN PRESSURE-GRADIENT MEASUREMENT BY CONTINUOUS WAVE DOPPLER ULTRASOUND - TYPE, SIZE AND AGE EFFECTS IN BIOPROSTHETIC AORTIC VALVES [J].
STEWART, SFC ;
NAST, EP ;
ARABIA, FA ;
TALBOT, TL ;
PROSCHAN, M ;
CLARK, RE .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1991, 18 (03) :769-779
[33]  
Sun JP, 1997, CIRCULATION, V95, P932
[34]   THE ACCURACY OF DOPPLER ULTRASOUND MEASUREMENT OF PRESSURE-GRADIENTS ACROSS IRREGULAR, DUAL, AND TUNNEL-LIKE OBSTRUCTIONS TO BLOOD-FLOW [J].
TEIRSTEIN, PS ;
YOCK, PG ;
POPP, RL .
CIRCULATION, 1985, 72 (03) :577-584
[35]   NUMERICAL MODELING OF VENTRICULAR FILLING [J].
THOMAS, JD ;
WEYMAN, AE .
ANNALS OF BIOMEDICAL ENGINEERING, 1992, 20 (01) :19-39
[36]   ECHOCARDIOGRAPHIC DOPPLER EVALUATION OF LEFT-VENTRICULAR DIASTOLIC FUNCTION - PHYSICS AND PHYSIOLOGY [J].
THOMAS, JD ;
WEYMAN, AE .
CIRCULATION, 1991, 84 (03) :977-990
[37]   QUANTIFICATION OF JET FLOW BY MOMENTUM ANALYSIS - AN INVITRO COLOR DOPPLER FLOW STUDY [J].
THOMAS, JD ;
LIU, CM ;
FLACHSKAMPF, FA ;
OSHEA, JP ;
DAVIDOFF, R ;
WEYMAN, AE .
CIRCULATION, 1990, 81 (01) :247-259
[38]  
TRITTON DJ, 1988, PHYSICAL FLUID DYNAM, P116
[39]  
Tsujino H, 1995, J Am Soc Echocardiogr, V8, P621, DOI 10.1016/S0894-7317(05)80375-X
[40]   Automated Flow Rate Calculations Based on Digital Analysis of Flow Convergence Proximal to Regurgitant Orifices [J].
Vandervoort, Pieter M. ;
Thoreau, David H. ;
Rivera, J. Miguel ;
Levine, Robert A. ;
Weyman, Arthur E. ;
Thomas, James D. .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1993, 22 (02) :535-541