RCADiA: Simple automation platform for comparative multidimensional identification technology protein

被引:9
作者
Bailey, Aaron O.
Miller, Timothy M.
Dong, Meng-Qiu
Velde, Christine Vande
Cleveland, Don W.
Yates, John R.
机构
[1] Scripps Res Inst, Dept Cell Biol, La Jolla, CA 92037 USA
[2] Univ Calif San Diego, Ludwig Inst Canc Res, La Jolla, CA 92093 USA
关键词
D O I
10.1021/ac070585g
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Multidimensional liquid chromatography in combination with tandem mass spectrometry has been used to analyze a variety of biological structures including protein complexes. Incorporating this approach with autosampling devices presents a number of problems including decreased sensitivity due to exposure to extra surfaces, carryover from run to run, and increased dead volume. We developed a device, termed Radial Column Array for Distribution and Automation (RCADiA), to automate multiple MuDPIT experiments while eliminating many of these problems and maintaining a high resolution and sensitive analysis. The design, which places each sample downstream of any common fluid path, presents a low risk of carryover between successive analyses. Beyond the convenience of automation, the RCADiA platform also produces data of similar quality to the standard method of performing individual MuDPIT experiments. We demonstrate this device by performing a comparative analysis of mitochondria enriched from rat liver and spinal cord.
引用
收藏
页码:6410 / 6418
页数:9
相关论文
共 21 条
[1]   Automatic Quality Assessment of Peptide Tandem Mass Spectra [J].
Bern, Marshall ;
Goldberg, David ;
McDonald, W. Hayes ;
Yates, John R., III .
BIOINFORMATICS, 2004, 20 :49-54
[2]   Human tissue profiling with multidimensional protein identification technology [J].
Cagney, G ;
Park, S ;
Chung, C ;
Tong, B ;
O'Dushlaine, C ;
Shields, DC ;
Emili, A .
JOURNAL OF PROTEOME RESEARCH, 2005, 4 (05) :1757-1767
[3]  
COCIORVA D, 2006, 54 ASMS C MASS SPECT
[4]  
Dolan JW, 2001, LC GC N AM, V19, P164
[5]   AN APPROACH TO CORRELATE TANDEM MASS-SPECTRAL DATA OF PEPTIDES WITH AMINO-ACID-SEQUENCES IN A PROTEIN DATABASE [J].
ENG, JK ;
MCCORMACK, AL ;
YATES, JR .
JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY, 1994, 5 (11) :976-989
[6]   Direct analysis of protein complexes using mass spectrometry [J].
Link, AJ ;
Eng, J ;
Schieltz, DM ;
Carmack, E ;
Mize, GJ ;
Morris, DR ;
Garvik, BM ;
Yates, JR .
NATURE BIOTECHNOLOGY, 1999, 17 (07) :676-682
[7]   Development of multichannel devices with an array of electrospray tips far high-throughput mass spectrometry [J].
Liu, HH ;
Felten, C ;
Xue, QF ;
Zhang, BL ;
Jedrzejewski, P ;
Karger, BL ;
Foret, F .
ANALYTICAL CHEMISTRY, 2000, 72 (14) :3303-3310
[8]   Comparison of three directly coupled HPLC MS/MS strategies for identification of proteins from complex mixtures: single-dimension LC-MS/MS, 2-phase MudPIT, and 3-phase MudPIT [J].
McDonald, WH ;
Ohi, R ;
Miyamoto, DT ;
Mitchison, TJ ;
Yates, JR .
INTERNATIONAL JOURNAL OF MASS SPECTROMETRY, 2002, 219 (01) :245-251
[9]   Subtractive proteomic mapping of the endothelial surface in lung and solid tumours for tissue-specific therapy [J].
Oh, P ;
Li, Y ;
Yu, JY ;
Durr, E ;
Krasinska, KM ;
Carver, LA ;
Testa, JE ;
Schnitzer, JE .
NATURE, 2004, 429 (6992) :629-635
[10]   Subcellular distribution of superoxide dismutases (SOD) in rat liver - Cu,Zn-SOD in mitochondria [J].
Okado-Matsumoto, A ;
Fridovich, I .
JOURNAL OF BIOLOGICAL CHEMISTRY, 2001, 276 (42) :38388-38393