Quantifying Doppler angle and mapping flow velocity by a combination of Doppler-shift and Doppler-bandwidth measurements in optical Doppler tomography

被引:13
作者
Piao, DQ [1 ]
Zhu, Q [1 ]
机构
[1] Univ Connecticut, Dept Elect & Comp Engn, Storrs, CT 06269 USA
关键词
D O I
10.1364/AO.42.005158
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
Recently we introduced a novel procedure that estimates Doppler angle and flow velocity simultaneously by combining Doppler-shift and Doppler-bandwidth measurements with a conventional single-beam optical Doppler tomography device. Here we validate this method experimentally with two Intralipid flow setups that correspond to fixed Doppler angle and fixed flow speed. One set of data has a fixed flow speed of 53.6 mm/s with a Doppler angle that changes from 56degrees to 90degrees; the other has a fixed Doppler angle of 80degrees with flow speed that changes from 18.5 to 141.9 mm/s. As obtained with the method introduced here; the Doppler-angle estimation accuracies of the two sets are 97.6% and 98.2%, respectively, and the estimation accuracies of flow speeds of the two sets are 94.3% and 90.4%, respectively. (C) 2003 Optical Society of America.
引用
收藏
页码:5158 / 5166
页数:9
相关论文
共 18 条
[1]  
CARO G, 1978, MECH CIRCULATION
[2]   Optical Doppler tomography [J].
Chen, ZP ;
Zhao, YH ;
Srinivas, SM ;
Nelson, JS ;
Prakash, N ;
Frostig, RD .
IEEE JOURNAL OF SELECTED TOPICS IN QUANTUM ELECTRONICS, 1999, 5 (04) :1134-1142
[3]   Blood speed imaging with an intraluminal array [J].
Crowe, JR ;
Shapo, BM ;
Stephens, DN ;
Bleam, D ;
Eberle, MJ ;
Céspedes, EI ;
Wu, CC ;
Muller, DWM ;
Kovach, JA ;
Lederman, RJ ;
O'Donnell, M .
IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 2000, 47 (03) :672-681
[4]   OPTICAL COHERENCE TOMOGRAPHY [J].
HUANG, D ;
SWANSON, EA ;
LIN, CP ;
SCHUMAN, JS ;
STINSON, WG ;
CHANG, W ;
HEE, MR ;
FLOTTE, T ;
GREGORY, K ;
PULIAFITO, CA ;
FUJIMOTO, JG .
SCIENCE, 1991, 254 (5035) :1178-1181
[5]   REAL-TIME TWO-DIMENSIONAL BLOOD-FLOW IMAGING USING AN AUTO-CORRELATION TECHNIQUE [J].
KASAI, C ;
NAMEKAWA, K ;
KOYANO, A ;
OMOTO, R .
IEEE TRANSACTIONS ON SONICS AND ULTRASONICS, 1985, 32 (03) :458-464
[6]   Velocity-estimation accuracy and frame-rate limitations in color Doppler optical coherence tomography [J].
Kulkarni, MD ;
van Leeuwen, TG ;
Yazdanfar, S ;
Izatt, JA .
OPTICS LETTERS, 1998, 23 (13) :1057-1059
[7]  
Li PC, 2001, IEEE T ULTRASON FERR, V48, P1084
[8]   THE DEPENDENCE OF ULTRASOUND DOPPLER BANDWIDTH ON BEAM GEOMETRY [J].
NEWHOUSE, VL ;
FURGASON, ES ;
JOHNSON, GF ;
WOLF, DA .
IEEE TRANSACTIONS ON SONICS AND ULTRASONICS, 1980, 27 (02) :50-59
[9]   RETINAL LASER DOPPLER VELOCIMETRY - TOWARD ITS COMPUTER-ASSISTED CLINICAL USE [J].
PETRIG, BL ;
RIVA, CE .
APPLIED OPTICS, 1988, 27 (06) :1126-1134
[10]   Doppler angle and flow velocity mapping by combined Doppler shift and Doppler bandwidth measurements in optical Doppler tomography [J].
Piao, DQ ;
Otis, LL ;
Zhu, Q .
OPTICS LETTERS, 2003, 28 (13) :1120-1122