Physiologic and Pathologic Changes in Patients with Continuous-Flow Ventricular Assist Devices

被引:36
作者
John, Ranjit [1 ,2 ]
Boyle, Andrew [3 ]
Pagani, Frank [4 ]
Miller, Leslie [5 ]
机构
[1] Univ Minnesota, Div Cardiothorac Surg, Minneapolis, MN 55455 USA
[2] Univ Minnesota, Dept Surg, Minneapolis, MN 55455 USA
[3] Univ Minnesota, Dept Med, Minneapolis, MN 55455 USA
[4] Univ Michigan, Dept Surg, Ann Arbor, MI 48109 USA
[5] Georgetown Univ, Washington Hosp Ctr, Div Cardiovasc, Washington, DC USA
关键词
LVAD; Left Ventricular Assist Device; End-Stage Heart Failure; Pulsatile Devices; Continuous Flow Devices; AWAITING HEART-TRANSPLANTATION; VON-WILLEBRAND-FACTOR; END-ORGAN FUNCTION; CIRCULATORY SUPPORT; AORTIC-STENOSIS; PULSATILE-FLOW; NONPULSATILE; SYSTEM; EXPERIENCE; RECIPIENTS;
D O I
10.1007/s12265-009-9092-y
中图分类号
R5 [内科学];
学科分类号
100201 [内科学];
摘要
The clinical use of the newer continuous-flow pumps for mechanical circulatory support have resulted in superior outcomes including significantly reduced complication rates with improved durability over first generation pulsatile design pumps. However, as with all new technology, the newer LVADs have introduced a different set of management issues, as well as a unique risk profile into the mechanical circulatory support arena that were previously absent or unimportant with pulsatile LVADs. These include the effects of continuous flow on the systemic circulation and end-organ function, risk of thromboembolism, and pump thrombosis related to contact bearings in the blood path, the possible increased incidence of gastrointestinal bleeding, and ventricular arrhythmias, as well as alterations in the unloading characteristics of continuous-flow devices. This manuscript overviews the physiologic and pathologic effects that are associated with continuous-flow pumps and their unique management issues and complications.
引用
收藏
页码:154 / 158
页数:5
相关论文
共 37 条
[1]
BOLEY SJ, 1977, GASTROENTEROLOGY, V72, P650
[2]
CAO X, 2006, 10 ANN SCI M HEART F
[3]
Gastrointestinal bleeding rates in recipients of nonpulsatile and pulsatile left ventricular assist devices [J].
Crow, Sheri ;
John, Ranjit ;
Boyle, Andrew ;
Shumway, Sara ;
Liao, Kenneth ;
Colvin-Adams, Monica ;
Toninato, Carol ;
Missov, Emil ;
Pritzker, Marc ;
Martin, Cindy ;
Garry, Daniel ;
Thomas, William ;
Joyce, Lyle .
JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 2009, 137 (01) :208-215
[4]
Pulmonary complications after descending thoracic and thoracoabdominal aortic aneurysm repair: Predictors, prevention, and treatment [J].
Etz, Christian D. ;
Di Luozzo, Gabriele ;
Bello, Ricardo ;
Luehr, Maximilian ;
Khan, Muhammad Z. ;
Bodian, Carol A. ;
Griepp, Randall B. ;
Plestis, Konstadinos A. .
ANNALS OF THORACIC SURGERY, 2007, 83 (02) :S870-S876
[5]
Clinical outcomes are similar in pulsatile and nonpulsatile left ventricular assist device recipients [J].
Feller, Erika D. ;
Sorensen, Erik N. ;
Haddad, Michel ;
Pierson, Richard N., III ;
Johnson, Frances L. ;
Brown, James M. ;
Griffith, Bartley P. .
ANNALS OF THORACIC SURGERY, 2007, 83 (03) :1082-1088
[6]
Frazier OH, 2007, TEX HEART I J, V34, P275
[7]
Multicenter clinical evaluation of the HeartMate vented electric left ventricular assist system in patients awaiting heart transplantation [J].
Frazier, OH ;
Rose, EA ;
Oz, MC ;
Dembitsky, W ;
McCarthy, P ;
Radovancevic, B ;
Poirier, VL ;
Dasse, KA .
JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 2001, 122 (06) :1186-1195
[8]
IMPROVED MORTALITY AND REHABILITATION OF TRANSPLANT CANDIDATES TREATED WITH A LONG-TERM IMPLANTABLE LEFT-VENTRICULAR ASSIST SYSTEM [J].
FRAZIER, OH ;
ROSE, EA ;
MCCARTHY, P ;
BURTON, NA ;
TECTOR, A ;
LEVIN, H ;
KAYNE, HL ;
POIRIER, VL ;
DASSE, KA .
ANNALS OF SURGERY, 1995, 222 (03) :327-338
[9]
von Willebrand factor: molecular size and functional activity [J].
Furlan, M .
ANNALS OF HEMATOLOGY, 1996, 72 (06) :341-348
[10]
Effects of pulsatile- and continuous-flow left ventricular assist devices on left ventricular unloading [J].
Garcia, Santiago ;
Kandar, Forum ;
Boyle, Andrew ;
Colvin-Adams, Monica ;
Lliao, Kenneth ;
Joyce, Lyle ;
John, Ranjit .
JOURNAL OF HEART AND LUNG TRANSPLANTATION, 2008, 27 (03) :261-267